Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Dosimetric verification and quality assurance for intensity-modulated radiation therapy using Gafchromic® EBT3 film

View through CrossRef
AbstractPurposeThis study aimed to examine the dosimetric properties of Gafchromic® EBT3 film and intensity-modulated radiation therapy quality assurance (IMRT QA).Materials and methodsBeams characteristics dosimetric properties and 20 IMRT plans were created and irradiated on Varian dual-energy DHX-S Linac for 6 and 15 MV energies. EBT3 films were analysed using ‘film Pro QA 2014’ software.ResultsThe dosimetric comparison of EBT3 film (for red channel dosimetry) and ionisation ion chamber measurement showed that average deviations of symmetry, flatness, central axis, penumbra (left) and penumbra (right) of dose profile were 0·18, 1·34, 0·49%, 3·68 and 3·61 mm for 6 MV and 0·10, 1·3, 0·45, 2·65 and 2·71 mm for 15 MV, respectively. The blue and green channels dosimetry showed greater dose deviation as compared with red channel. IMRT QA verification plan complied about 95% at all different criteria. Reproducibility, stability and face orientation of film were within 1·4% for red channel.ConclusionsThe results advocate that the film can be used not only for dosimetric assessment but also as a reliable IMRT QA tool.
Title: Dosimetric verification and quality assurance for intensity-modulated radiation therapy using Gafchromic® EBT3 film
Description:
AbstractPurposeThis study aimed to examine the dosimetric properties of Gafchromic® EBT3 film and intensity-modulated radiation therapy quality assurance (IMRT QA).
Materials and methodsBeams characteristics dosimetric properties and 20 IMRT plans were created and irradiated on Varian dual-energy DHX-S Linac for 6 and 15 MV energies.
EBT3 films were analysed using ‘film Pro QA 2014’ software.
ResultsThe dosimetric comparison of EBT3 film (for red channel dosimetry) and ionisation ion chamber measurement showed that average deviations of symmetry, flatness, central axis, penumbra (left) and penumbra (right) of dose profile were 0·18, 1·34, 0·49%, 3·68 and 3·61 mm for 6 MV and 0·10, 1·3, 0·45, 2·65 and 2·71 mm for 15 MV, respectively.
The blue and green channels dosimetry showed greater dose deviation as compared with red channel.
IMRT QA verification plan complied about 95% at all different criteria.
Reproducibility, stability and face orientation of film were within 1·4% for red channel.
ConclusionsThe results advocate that the film can be used not only for dosimetric assessment but also as a reliable IMRT QA tool.

Related Results

Characterization of EBT3 radiochromic films for dosimetry of proton beams in the presence of magnetic fields
Characterization of EBT3 radiochromic films for dosimetry of proton beams in the presence of magnetic fields
PurposeRadiochromic film dosimetry is extensively used for quality assurance in photon and proton beam therapy. So far, GafchromicTM EBT3 film appears as a strong candidate to be u...
Verifikasi Dosis Radiasi Teknik Penyinaran 3D-CRT pada Pasien Kanker Payudara Menggunakan Film EBT3 di Rumah Sakit UNAND
Verifikasi Dosis Radiasi Teknik Penyinaran 3D-CRT pada Pasien Kanker Payudara Menggunakan Film EBT3 di Rumah Sakit UNAND
Verifikasi dosis radiasi teknik penyinaran Three-Dimensional Conformal Radiation Therapy  (3D-CRT) pada pasien kanker payudara telah dilakukan menggunakan film EBT3. Verifikasi do...
SU‐GG‐T‐173: Dosimetric Verification of IMRT Fields Using GafChromic® EBT‐2 Film
SU‐GG‐T‐173: Dosimetric Verification of IMRT Fields Using GafChromic® EBT‐2 Film
Purpose: Film based dosimetry often has advantages over detector based dosimetry when measurements with high spatial resolution are needed. We present comparisons of dosimetric ver...
Characteristic of EBT-XD and EBT3 radiochromic film dosimetry for photon and proton beams
Characteristic of EBT-XD and EBT3 radiochromic film dosimetry for photon and proton beams
Abstract Recently, a new type of radiochromic film, the EBT-XD film, has been introduced for high dose radiotherapy. The EBT-XD film contains the same structure a...
Reclaiming the Wasteland: Samson and Delilah and the Historical Perception and Construction of Indigenous Knowledges in Australian Cinema
Reclaiming the Wasteland: Samson and Delilah and the Historical Perception and Construction of Indigenous Knowledges in Australian Cinema
It was always based on a teenage love story between the two kids. One is a sniffer and one is not. It was designed for Central Australia because we do write these kids off there. N...
GafChromic MD‐55: Investigated as a precision dosimeter
GafChromic MD‐55: Investigated as a precision dosimeter
GafChromic MD‐55 is a fairly new, thin film dosimeter that develops a blue color when irradiated with ionizing radiation. The increase in absorbance is roughly proportional to the...
Benchmarking a GATE/Geant4 Monte Carlo model for proton beams in magnetic fields
Benchmarking a GATE/Geant4 Monte Carlo model for proton beams in magnetic fields
PurposeMagnetic resonance guidance in proton therapy (MRPT) is expected to improve its current performance. The combination of magnetic fields with clinical proton beam lines poses...
Expired EBT3 Films’ Sensitivity for the Measurement of X-ray and UV Radiation: An Optical Analysis
Expired EBT3 Films’ Sensitivity for the Measurement of X-ray and UV Radiation: An Optical Analysis
The aim of this study is to compare the optical responses of external beam therapy 3 (EBT3) films exposed to X-rays and solar ultraviolet rays (SUV-rays), as a dose control techniq...

Back to Top