Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Verifikasi Dosis Radiasi Teknik Penyinaran 3D-CRT pada Pasien Kanker Payudara Menggunakan Film EBT3 di Rumah Sakit UNAND

View through CrossRef
Verifikasi dosis radiasi teknik penyinaran Three-Dimensional Conformal Radiation Therapy  (3D-CRT) pada pasien kanker payudara telah dilakukan menggunakan film EBT3. Verifikasi dosis radiasi dilakukan di Rumah Sakit Universitas Andalas selama Agustus sampai September 2020. Pengukuran dosis radiasi menggunakan film EBT3 dilakukan untuk memverifikasi dosis radiasi terukur dengan Treatment Planning System (TPS) berdasarkan protokol International Atomic Energy Agency (IAEA) Technical Report Series (TRS) 398. Nilai dosis radiasi terukur diamati pada setiap lapangan penyinaran yaitu chest-wall dan supraclave. Verifikasi dosis radiasi dari penyinaran dosis radiasi yang terukur menggunakan film EBT3 mendapatkan nilai dosis radiasi yang lebih tinggi dari dosis radiasi TPS. Nilai dari pengukuran dosis radiasi menunjukkan dosis radiasi terukur pada lapangan penyinaran chest-wall cenderung tinggi jika dibandingkan dengan dosis radiasi terukur pada lapangan penyinaran supraclave. Hasil pengukuran dosis radiasi yang tinggi pada lapangan penyinaran chest-wall disebabkan adanya penggunaan bolus. Berdasarkan hasil pengukuran dosis radiasi tersebut verifikasi dosis radiasi berdasarkan TRS 398 tidak terpenuhi. Diskrepansi dosis radiasi terukur pada setiap pengukuran melebihi standar toleransi TRS 398 yaitu (0-5)% Dose verification of Three-Dimensional Conformal Radiation Therapy (3D-CRT) for breast cancer patient has been conducted using film EBT3. The dose radiation had been verificated in Andalas University Hospital from August to September in 2020. Dose radiation measurement using film EBT3 has been verified the dose radiation of Treatment Planning System (TPS) based on International Atomic Energy Agency (IAEA) Technical Report Series (TRS) 398. The measurable of dose radiation has been observed for chest-wall and supraclave. It was shown that the value of measurable dose radiation is higher than dose radiation in the TPS. The value of dose radiation measurement between chest-wall and supraclave showed different pattern. Measurable dose radiation on Chest-wall is tend to higher value than on supraclave. This pattern is may be due to that radiation treatment on chest-wall was using bolus. Furthermore, the dose radiation discrepancy using film EBT3 exceed the standard limitation base on TRS 398. Thus, the dose verification using film EBT3 is not properly enough for breast cancer patient.
Title: Verifikasi Dosis Radiasi Teknik Penyinaran 3D-CRT pada Pasien Kanker Payudara Menggunakan Film EBT3 di Rumah Sakit UNAND
Description:
Verifikasi dosis radiasi teknik penyinaran Three-Dimensional Conformal Radiation Therapy  (3D-CRT) pada pasien kanker payudara telah dilakukan menggunakan film EBT3.
Verifikasi dosis radiasi dilakukan di Rumah Sakit Universitas Andalas selama Agustus sampai September 2020.
Pengukuran dosis radiasi menggunakan film EBT3 dilakukan untuk memverifikasi dosis radiasi terukur dengan Treatment Planning System (TPS) berdasarkan protokol International Atomic Energy Agency (IAEA) Technical Report Series (TRS) 398.
Nilai dosis radiasi terukur diamati pada setiap lapangan penyinaran yaitu chest-wall dan supraclave.
Verifikasi dosis radiasi dari penyinaran dosis radiasi yang terukur menggunakan film EBT3 mendapatkan nilai dosis radiasi yang lebih tinggi dari dosis radiasi TPS.
Nilai dari pengukuran dosis radiasi menunjukkan dosis radiasi terukur pada lapangan penyinaran chest-wall cenderung tinggi jika dibandingkan dengan dosis radiasi terukur pada lapangan penyinaran supraclave.
Hasil pengukuran dosis radiasi yang tinggi pada lapangan penyinaran chest-wall disebabkan adanya penggunaan bolus.
Berdasarkan hasil pengukuran dosis radiasi tersebut verifikasi dosis radiasi berdasarkan TRS 398 tidak terpenuhi.
Diskrepansi dosis radiasi terukur pada setiap pengukuran melebihi standar toleransi TRS 398 yaitu (0-5)% Dose verification of Three-Dimensional Conformal Radiation Therapy (3D-CRT) for breast cancer patient has been conducted using film EBT3.
The dose radiation had been verificated in Andalas University Hospital from August to September in 2020.
Dose radiation measurement using film EBT3 has been verified the dose radiation of Treatment Planning System (TPS) based on International Atomic Energy Agency (IAEA) Technical Report Series (TRS) 398.
The measurable of dose radiation has been observed for chest-wall and supraclave.
It was shown that the value of measurable dose radiation is higher than dose radiation in the TPS.
The value of dose radiation measurement between chest-wall and supraclave showed different pattern.
Measurable dose radiation on Chest-wall is tend to higher value than on supraclave.
This pattern is may be due to that radiation treatment on chest-wall was using bolus.
Furthermore, the dose radiation discrepancy using film EBT3 exceed the standard limitation base on TRS 398.
Thus, the dose verification using film EBT3 is not properly enough for breast cancer patient.

Related Results

FAKTOR-FAKTOR YANG MEMPENGARUHI MORTALITAS PADA PASIEN DENGAN FRAKTUR COSTA: Literature Review
FAKTOR-FAKTOR YANG MEMPENGARUHI MORTALITAS PADA PASIEN DENGAN FRAKTUR COSTA: Literature Review
FAKTOR-FAKTOR YANG MEMPENGARUHI MORTALITAS PADA PASIEN DENGAN FRAKTUR COSTA: Literature  Review Anna Tri Wahyuni1), Masfuri2),  Liya Arista3)1,2,3 Fakultas Ilmu Keperawatan Univers...
Karakteristik Penyebab Kanker Payudara
Karakteristik Penyebab Kanker Payudara
Kanker payudara merupakan penyebab kematian ke 2 setelah kanker rahim. Berdasarkan data yang diperoleh dari Dinas Kesehatan Kota Padang tentang kejadian kanker payudara, pada tahun...
Evaluasi Penerapan Proteksi Radiasi pada Pekerja Radiasi di Instalasi Radiologi RS Naili DBS, RS Selaguri, dan RS UNAND
Evaluasi Penerapan Proteksi Radiasi pada Pekerja Radiasi di Instalasi Radiologi RS Naili DBS, RS Selaguri, dan RS UNAND
Telah dilakukan penelitian tentang penerapan proteksi radiasi pada pekerja radiasi di Instalasi Radiologi RS Naili DBS, RS Selaguri dan RS UNAND.  Penelitian bertujuan untuk menge...
Karakteristik Kanker Panyudara
Karakteristik Kanker Panyudara
Kanker payudara menempati urutan pertama jumlah kasus kanker sekaligus menjadi penyebab kematian terbesar akibat kanker di dunia setiap tahunnya. Adapun faktor risiko yang erat kai...
Profil dan Karakteristik Pasien Kanker Payudara di RSUP dr. Soeradji Tirtonegoro Klaten
Profil dan Karakteristik Pasien Kanker Payudara di RSUP dr. Soeradji Tirtonegoro Klaten
LATAR BELAKANG : Kanker payudara adalah kanker dengan prevalensi tertinggi secara global pada perempuan. Sebanyak 30,1% kasus kanker pada perempuan di Indonesia merupakan kanker pa...
Gambaran stadium dan jenis histopatologi kanker payudara di Subbagian Bedah Onkologi RSUP Sanglah Denpasar tahun 2015-2016
Gambaran stadium dan jenis histopatologi kanker payudara di Subbagian Bedah Onkologi RSUP Sanglah Denpasar tahun 2015-2016
Latar Belakang: Kanker payudara merupakan suatu penyakit neoplasma yang ganas dimana pada jaringan parekim terdapat pertumbuhan jaringan payudara abnormal yang bersifat infiltratif...
Analisis Farmakoekonomi Terhadap Regimen Kemoterapi Pasien Kanker Payudara Di Rumah Sakit Universitas Hasanuddin Makassar
Analisis Farmakoekonomi Terhadap Regimen Kemoterapi Pasien Kanker Payudara Di Rumah Sakit Universitas Hasanuddin Makassar
Therapy given to breast cancer patients is usually carried out in several cycles, while the cost of treatment increases every year, so this situation can become an economic burden ...

Back to Top