Javascript must be enabled to continue!
Expired EBT3 Films’ Sensitivity for the Measurement of X-ray and UV Radiation: An Optical Analysis
View through CrossRef
The aim of this study is to compare the optical responses of external beam therapy 3 (EBT3) films exposed to X-rays and solar ultraviolet rays (SUV-rays), as a dose control technique in the clinical sector for various radiation types, energies, and absorbed doses up to 4 Gy. In this study, EBT3 films with three different expiry dates were prepared and cut into pieces of size 2 by 2 cm2. The first group was exposed to 90 kVp X-rays, while the second group was exposed to the SUV-rays at noon. The analysis was performed using a visible Jaz spectrometer and an EPSON Perfection V370 Photo scanner to obtain the absorbance, the net reflective optical density (ROD) and the red-green-blue (RGB) values of the samples. The results have shown that spectroscopic measurements of the exposed expired EBT3 films with these radiation sources are able to produce primary peaks and secondary peaks at λ = 641.74 nm and λ = 585.98 nm for X-rays, and at λ = 637.93 nm and λ = 584.45 nm for SUV-rays, respectively. According to these findings, compared to 2021 films that expired shortly before the trial start date; 2018 films responded better to the absorbed dose than 2016 films when exposed to both X-ray and SUV-rays. In terms of energy dependence, the expired EBT3 2018 had the largest net ROD value. Using L*a*b* indices extracted from the RGB data, and despite that EBT3 films have expiry dates according to the manufacturer; all the films exhibited a substantial colour change, indicating that these films are still usable for clinical and research purposes.
Title: Expired EBT3 Films’ Sensitivity for the Measurement of X-ray and UV Radiation: An Optical Analysis
Description:
The aim of this study is to compare the optical responses of external beam therapy 3 (EBT3) films exposed to X-rays and solar ultraviolet rays (SUV-rays), as a dose control technique in the clinical sector for various radiation types, energies, and absorbed doses up to 4 Gy.
In this study, EBT3 films with three different expiry dates were prepared and cut into pieces of size 2 by 2 cm2.
The first group was exposed to 90 kVp X-rays, while the second group was exposed to the SUV-rays at noon.
The analysis was performed using a visible Jaz spectrometer and an EPSON Perfection V370 Photo scanner to obtain the absorbance, the net reflective optical density (ROD) and the red-green-blue (RGB) values of the samples.
The results have shown that spectroscopic measurements of the exposed expired EBT3 films with these radiation sources are able to produce primary peaks and secondary peaks at λ = 641.
74 nm and λ = 585.
98 nm for X-rays, and at λ = 637.
93 nm and λ = 584.
45 nm for SUV-rays, respectively.
According to these findings, compared to 2021 films that expired shortly before the trial start date; 2018 films responded better to the absorbed dose than 2016 films when exposed to both X-ray and SUV-rays.
In terms of energy dependence, the expired EBT3 2018 had the largest net ROD value.
Using L*a*b* indices extracted from the RGB data, and despite that EBT3 films have expiry dates according to the manufacturer; all the films exhibited a substantial colour change, indicating that these films are still usable for clinical and research purposes.
Related Results
Characterization of EBT3 radiochromic films for dosimetry of proton beams in the presence of magnetic fields
Characterization of EBT3 radiochromic films for dosimetry of proton beams in the presence of magnetic fields
PurposeRadiochromic film dosimetry is extensively used for quality assurance in photon and proton beam therapy. So far, GafchromicTM EBT3 film appears as a strong candidate to be u...
Verifikasi Dosis Radiasi Teknik Penyinaran 3D-CRT pada Pasien Kanker Payudara Menggunakan Film EBT3 di Rumah Sakit UNAND
Verifikasi Dosis Radiasi Teknik Penyinaran 3D-CRT pada Pasien Kanker Payudara Menggunakan Film EBT3 di Rumah Sakit UNAND
Verifikasi dosis radiasi teknik penyinaran Three-Dimensional Conformal Radiation Therapy  (3D-CRT) pada pasien kanker payudara telah dilakukan menggunakan film EBT3. Verifikasi do...
Alternative Entrances: Phillip Noyce and Sydney’s Counterculture
Alternative Entrances: Phillip Noyce and Sydney’s Counterculture
Phillip Noyce is one of Australia’s most prominent film makers—a successful feature film director with both iconic Australian narratives and many a Hollywood blockbuster under his ...
COMPARATIVE STUDY ON THE EFFECT OF EXPIRED AND NONEXPIRED RANGLIM TABLET ON SOIL QUALITY
COMPARATIVE STUDY ON THE EFFECT OF EXPIRED AND NONEXPIRED RANGLIM TABLET ON SOIL QUALITY
In pharmaceuticals, Antidiabetic drugs are one among the medicine used to treat diabetes Miletus. These pharmaceuticals enter into the environment through various routes like human...
Characteristic of EBT-XD and EBT3 radiochromic film dosimetry for photon and proton beams
Characteristic of EBT-XD and EBT3 radiochromic film dosimetry for photon and proton beams
Abstract
Recently, a new type of radiochromic film, the EBT-XD film, has been introduced for high dose radiotherapy. The EBT-XD film contains the same structure a...
Desarrollo de nuevas estructuras laminares de nanocelulosa con propiedades avanzadas para el packaging
Desarrollo de nuevas estructuras laminares de nanocelulosa con propiedades avanzadas para el packaging
(English) Changes in the use of raw materials and major lifestyle changes in first world societies have driven the massive use of petroleum-based materials in a wide range of appli...
Spray Coated Nanocellulose Films Productions, Characterization and Application
Spray Coated Nanocellulose Films Productions, Characterization and Application
Nanocellulose (NC) is a biodegradable, renewable and sustainable material. It has strong potential to use as a functional material in various applications such as barriers, coating...
Pertumbuhan dan Hasil Tanaman Jagung (Zea mays L.) Kadaluarsa dengan Pemberian Berbagai Zat Pengatur Tumbuh
Pertumbuhan dan Hasil Tanaman Jagung (Zea mays L.) Kadaluarsa dengan Pemberian Berbagai Zat Pengatur Tumbuh
Plant growth regulators are organic or synthetic compounds that function to regulate and stimulate plant growth, both in the vegetative and generative phases. The administration of...

