Characterization of EBT3 radiochromic films for dosimetry of proton beams in the presence of magnetic fields
View through CrossRef
PurposeRadiochromic film dosimetry is extensively used for quality assurance in photon and proton beam therapy. So far, GafchromicTM EBT3 film appears as a strong candidate to be used in future magnetic resonance (MR) based therapy systems. The response of Gafchromic EBT3 films in the presence of magnetic fields has already been addressed for different MR‐linacs systems. However, a detailed evaluation of the influence of external magnetic fields on the film response and calibration curves for proton therapy has not yet been reported. This study aims to determine the dose responses of EBT3 films for clinical proton beams exposed to magnetic field strengths up to 1 T in order to investigate the feasibility of EBT3 film as an accurate dosimetric tool for a future MR particle therapy system (MRPT).MethodsThe dosimetric characteristics of EBT3 films were studied for a proton beam passing through magnetic field strengths of B = 0, 0.5, and 1 T. Absorbed dose calibration and measurements were performed using clinical proton beams in the nominal energy range of 62.4–252.6 MeV. Irradiations were done using an in‐house developed PMMA slab phantom placed in the center of a dipole research magnet. Monte Carlo (MC) simulations using the GATE/Geant4 toolkit were performed to predict the effect of magnetic fields on the energy deposited by proton beams in the phantom. Planned and measured doses from 3D box cube irradiations were compared to assess the accuracy of the dosimetric method using EBT3 films with/without the external magnetic field.ResultsNeither for the mean pixel value nor for the net optical density, any significant deviations were observed due to the presence of an external magnetic field (B ≤ 1T) for doses up to 10 Gy. Dose‐response curves for the red channel were fitted by a three‐parameter function for the field‐free case and for B = 1T, showing for both cases an R‐square coefficient of unity and almost identical fitting parameters. Independently of the magnetic field, EBT3 films showed an under‐response as high as 8% in the Bragg peak region, similarly to previously reported effects for particle therapy. No noticeable influence of the magnetic field strength was observed on the quenching effect of the EBT3 films.ConclusionsFor the first time detailed absorbed dose calibrations of EBT3 films for proton beams in magnetic field regions were performed. Results showed that EBT3 films represent an attractive solution for the dosimetry of a future MRPT system. As film response functions for protons are not affected by the magnetic field strenght, they can be used for further investigations to evaluate the dosimetric effects induced due to particle beams bending in magnetic fields regions.
Title: Characterization of EBT3 radiochromic films for dosimetry of proton beams in the presence of magnetic fields
Description:
PurposeRadiochromic film dosimetry is extensively used for quality assurance in photon and proton beam therapy.
So far, GafchromicTM EBT3 film appears as a strong candidate to be used in future magnetic resonance (MR) based therapy systems.
The response of Gafchromic EBT3 films in the presence of magnetic fields has already been addressed for different MR‐linacs systems.
However, a detailed evaluation of the influence of external magnetic fields on the film response and calibration curves for proton therapy has not yet been reported.
This study aims to determine the dose responses of EBT3 films for clinical proton beams exposed to magnetic field strengths up to 1 T in order to investigate the feasibility of EBT3 film as an accurate dosimetric tool for a future MR particle therapy system (MRPT).
MethodsThe dosimetric characteristics of EBT3 films were studied for a proton beam passing through magnetic field strengths of B = 0, 0.
5, and 1 T.
Absorbed dose calibration and measurements were performed using clinical proton beams in the nominal energy range of 62.
4–252.
6 MeV.
Irradiations were done using an in‐house developed PMMA slab phantom placed in the center of a dipole research magnet.
Monte Carlo (MC) simulations using the GATE/Geant4 toolkit were performed to predict the effect of magnetic fields on the energy deposited by proton beams in the phantom.
Planned and measured doses from 3D box cube irradiations were compared to assess the accuracy of the dosimetric method using EBT3 films with/without the external magnetic field.
ResultsNeither for the mean pixel value nor for the net optical density, any significant deviations were observed due to the presence of an external magnetic field (B ≤ 1T) for doses up to 10 Gy.
Dose‐response curves for the red channel were fitted by a three‐parameter function for the field‐free case and for B = 1T, showing for both cases an R‐square coefficient of unity and almost identical fitting parameters.
Independently of the magnetic field, EBT3 films showed an under‐response as high as 8% in the Bragg peak region, similarly to previously reported effects for particle therapy.
No noticeable influence of the magnetic field strength was observed on the quenching effect of the EBT3 films.
ConclusionsFor the first time detailed absorbed dose calibrations of EBT3 films for proton beams in magnetic field regions were performed.
Results showed that EBT3 films represent an attractive solution for the dosimetry of a future MRPT system.
As film response functions for protons are not affected by the magnetic field strenght, they can be used for further investigations to evaluate the dosimetric effects induced due to particle beams bending in magnetic fields regions.
Related Results
Characteristic of EBT-XD and EBT3 radiochromic film dosimetry for photon and proton beams
Characteristic of EBT-XD and EBT3 radiochromic film dosimetry for photon and proton beams
Abstract
Recently, a new type of radiochromic film, the EBT-XD film, has been introduced for high dose radiotherapy. The EBT-XD film contains the same structure a...
Benchmarking a GATE/Geant4 Monte Carlo model for proton beams in magnetic fields
Benchmarking a GATE/Geant4 Monte Carlo model for proton beams in magnetic fields
PurposeMagnetic resonance guidance in proton therapy (MRPT) is expected to improve its current performance. The combination of magnetic fields with clinical proton beam lines poses...
Alternative Entrances: Phillip Noyce and Sydney’s Counterculture
Alternative Entrances: Phillip Noyce and Sydney’s Counterculture
Phillip Noyce is one of Australia’s most prominent film makers—a successful feature film director with both iconic Australian narratives and many a Hollywood blockbuster under his ...
Measurements of Radiochromic Films (EBT3 and EBT-XD) Using Three Portable Colorimeters
Measurements of Radiochromic Films (EBT3 and EBT-XD) Using Three Portable Colorimeters
The authors recently proposed a method for on-site dosimetry by a combination of radiochromic film and portable colorimeter. To test and expand the applicability of this method, do...
Verifikasi Dosis Radiasi Teknik Penyinaran 3D-CRT pada Pasien Kanker Payudara Menggunakan Film EBT3 di Rumah Sakit UNAND
Verifikasi Dosis Radiasi Teknik Penyinaran 3D-CRT pada Pasien Kanker Payudara Menggunakan Film EBT3 di Rumah Sakit UNAND
Verifikasi dosis radiasi teknik penyinaran Three-Dimensional Conformal Radiation Therapy  (3D-CRT) pada pasien kanker payudara telah dilakukan menggunakan film EBT3. Verifikasi do...
Ultraviolet radiation dosimetry using radiochromic film for extended dose range applications and estimating eye exposure
Ultraviolet radiation dosimetry using radiochromic film for extended dose range applications and estimating eye exposure
Abstract
Radiochromic films are a reliable tool for quantifying ultraviolet exposure dose. When used without modification, these films enable a simple, low-cost m...
Odd version Mathieu-Gaussian beam based on Green function
Odd version Mathieu-Gaussian beam based on Green function
Like the theoretical pattern of non-diffracting Bessel beams, ideal non-diffracting Mathieu beams also carry infinite energy, but cannot be generated as a physically realizable ent...
Desarrollo de nuevas estructuras laminares de nanocelulosa con propiedades avanzadas para el packaging
Desarrollo de nuevas estructuras laminares de nanocelulosa con propiedades avanzadas para el packaging
(English) Changes in the use of raw materials and major lifestyle changes in first world societies have driven the massive use of petroleum-based materials in a wide range of appli...