Effect of Ambient Temperature on Leakage Current of Gapless Metal Oxide Surge Arrester

View through CrossRef
Zinc oxide (ZnO) gapless surge arresters are used for lightning and overvoltage protection in electrical power system. The leakage current monitoring is one of the well known method for the ZnO surge arrester ageing level determination. However, the ZnO leakage current is known to be dependent on the ambient temperature. This paper aims to study the effects of temperature variation due to ambient conditions on the leakage current of ZnO surge arrester. The effect of a significant increment of leakage current with an increase in temperature may result in a wrong assesment of the ageing level of the arrester. The leakage current of three 120kV rated polymeric housed ZnO surge arresters were measured in a custom made thermally insulated enclosures at varying temperatures. Up to 20% increase in the leakage current was observed with a 20°C increment above the ambient temperature. For a typical variation of ambient temperature in Malaysia in the range of between 30°C and 40°C, the corresponding changes in the leakage current can be up to 11%. The temperature does significantly affect the leakage current measurements used for monitoring of zinc oxide surge arresters. This significant change in the leakage current due to ambient temperature variation can affect the decision in assessing the condition of surge arresters during routine monitoring.
Title: Effect of Ambient Temperature on Leakage Current of Gapless Metal Oxide Surge Arrester
Description:
Zinc oxide (ZnO) gapless surge arresters are used for lightning and overvoltage protection in electrical power system.
The leakage current monitoring is one of the well known method for the ZnO surge arrester ageing level determination.
However, the ZnO leakage current is known to be dependent on the ambient temperature.
This paper aims to study the effects of temperature variation due to ambient conditions on the leakage current of ZnO surge arrester.
The effect of a significant increment of leakage current with an increase in temperature may result in a wrong assesment of the ageing level of the arrester.
The leakage current of three 120kV rated polymeric housed ZnO surge arresters were measured in a custom made thermally insulated enclosures at varying temperatures.
Up to 20% increase in the leakage current was observed with a 20°C increment above the ambient temperature.
For a typical variation of ambient temperature in Malaysia in the range of between 30°C and 40°C, the corresponding changes in the leakage current can be up to 11%.
The temperature does significantly affect the leakage current measurements used for monitoring of zinc oxide surge arresters.
This significant change in the leakage current due to ambient temperature variation can affect the decision in assessing the condition of surge arresters during routine monitoring.

Related Results

PENGUJIAN DALAM PENGGUNAAN DAN DIAGNOSIS ARRESTER METAL OXIDE TANPA CELAH
PENGUJIAN DALAM PENGGUNAAN DAN DIAGNOSIS ARRESTER METAL OXIDE TANPA CELAH
This paper describes the testing strategies and risk assessment services for use in the diagnosis of metal oxide arrester without gaps that are installed substations. Different cas...
Effect of Ambient Temperature Zinc Oxide Surge Arrester Condition Monitoring
Effect of Ambient Temperature Zinc Oxide Surge Arrester Condition Monitoring
Various methods have been developed to monitor surge arrester condition and predict the probable interruption which can be caused by the failure of surge arresters. This paper aims...
Analisa Karakteristik Arrester pada Gardu Distribusi 20 kV ST 350 Penyulang Merpati
Analisa Karakteristik Arrester pada Gardu Distribusi 20 kV ST 350 Penyulang Merpati
Arrester  salah satu peralatan pada sistem tenaga listrk yang dapat melindungi peralatan listrik dari gangguan eksternal yang diakibatkan oleh tegangan lebih surja petir.  Analisa ...
Studi Pengaruh Kelembapan dan Polutan pada Kinerja Isolator Arrester 20 kV
Studi Pengaruh Kelembapan dan Polutan pada Kinerja Isolator Arrester 20 kV
Arrester merupakan sebuah perangkat yang berfungsi untuk melindungi peralatan dari kegagalan dielektrik yang disebabkan oleh impuls petir, switching surge, ataupun lonjakan teganga...
Multiple Water and Sand Leakage Model Tests for Shield Tunnel
Multiple Water and Sand Leakage Model Tests for Shield Tunnel
Water and sand leakage in shield tunnels has become more of a research interest in recent years. On the other hand, accidents involving underground engineering can take many forms ...
Analisis Arrester Sebagai Sistem Proteksi Pada Transformator di Gardu Induk Keramasan
Analisis Arrester Sebagai Sistem Proteksi Pada Transformator di Gardu Induk Keramasan
Lightning overvoltage is a periodic overvoltage caused by external causes. An arrester is equipment that protects installations from overvoltage disturbances due to lightning strik...
PERFORMANCE STUDY OF OVERVOLTAGE CUTTING BY LIGHTNING ARRESTER DUE TO LIGHTNING INDUCTION
PERFORMANCE STUDY OF OVERVOLTAGE CUTTING BY LIGHTNING ARRESTER DUE TO LIGHTNING INDUCTION
Lightning disturbances often cause induced overvoltages on 20 kV medium voltage distribution overhead lines, which can shorten equipment life and trigger power outages. This study ...