Analisis Arrester Sebagai Sistem Proteksi Pada Transformator di Gardu Induk Keramasan
View through CrossRef
Lightning overvoltage is a periodic overvoltage caused by external causes. An arrester is equipment that protects installations from overvoltage disturbances due to lightning strikes or electrical surges. The transformer functions to distribute electrical power by increasing or decreasing the voltage at the substation. This research focuses on substation equipment, namely the type 3EP 2150-2PL3 arrester connected to a 100 MVA IBT Transformer. Good protection is obtained if the arrester is placed as close to the transformer as possible. Therefore, this distance is determined so that protection can take place properly. The distance between the arrester and the transformer used at the Keramasan 150 KV substation is 5 m. while from the calculation results it is 22.5 m. based on SPLN 7: 1978 that for a 150 kV system the distance between the lightning catcher and the transformer does not exceed 80 m. This means that the distance between the arrester and the 100 MVA IBT Power Transformer is still within the limits set by PT PLN. The continuity of the spark that occurs in the arrester is still within safe limits and in accordance with mathematical analysis.
Politeknik Pratama Purwokerto
Title: Analisis Arrester Sebagai Sistem Proteksi Pada Transformator di Gardu Induk Keramasan
Description:
Lightning overvoltage is a periodic overvoltage caused by external causes.
An arrester is equipment that protects installations from overvoltage disturbances due to lightning strikes or electrical surges.
The transformer functions to distribute electrical power by increasing or decreasing the voltage at the substation.
This research focuses on substation equipment, namely the type 3EP 2150-2PL3 arrester connected to a 100 MVA IBT Transformer.
Good protection is obtained if the arrester is placed as close to the transformer as possible.
Therefore, this distance is determined so that protection can take place properly.
The distance between the arrester and the transformer used at the Keramasan 150 KV substation is 5 m.
while from the calculation results it is 22.
5 m.
based on SPLN 7: 1978 that for a 150 kV system the distance between the lightning catcher and the transformer does not exceed 80 m.
This means that the distance between the arrester and the 100 MVA IBT Power Transformer is still within the limits set by PT PLN.
The continuity of the spark that occurs in the arrester is still within safe limits and in accordance with mathematical analysis.
.
Related Results
Pengaruh Variasi Pembebanan Pada Kinerja Transformator 60 MVA di PT. PLN Gardu Induk Keramasan
Pengaruh Variasi Pembebanan Pada Kinerja Transformator 60 MVA di PT. PLN Gardu Induk Keramasan
Gardu Induk Keramasan melayani sistem distribusi tenaga listrik dengan pola pembebanan yang bersifat fluktuatif setiap harinya. Fluktuasi beban tersebut berpotensi menimbulkan rugi...
ANALISA PENGARUH PEMBEBANAN TERHADAP EFISIENSI DAN USIA PAKAI TRANSFORMATOR PADA PENYULANG BANDARA 2
ANALISA PENGARUH PEMBEBANAN TERHADAP EFISIENSI DAN USIA PAKAI TRANSFORMATOR PADA PENYULANG BANDARA 2
Beban yang bersifat fluktuatif dapat menimbulkan rugi-rugi pada transformator. Ketika suatu transformator diberi energi akan timbul rugi-rugi inti, rugi-rugi kumparan dan rugi-rugi...
supriyatna ANALISIS KOORDINASI ISOLASI DI GARDU INDUK KUTA TERHADAP TEGANGAN LEBIH AKIBAT SAMBARAN PETIR PADA SALURAN TRANSMISI 150 KV (Pak Supriyatna)
supriyatna ANALISIS KOORDINASI ISOLASI DI GARDU INDUK KUTA TERHADAP TEGANGAN LEBIH AKIBAT SAMBARAN PETIR PADA SALURAN TRANSMISI 150 KV (Pak Supriyatna)
Sambaran petir pada saluran transmisi 150 kV dapat menimbulkan tegangan lebih yang akan membahayakan peralatan jika tegangan tersebut melampaui tingkat isolasi dasar peralatan (TID...
Pengembangan Relai Adaptif Proteksi Busbar Menggunakan Relai Berbasis Protokol IEC61850
Pengembangan Relai Adaptif Proteksi Busbar Menggunakan Relai Berbasis Protokol IEC61850
Kebutuhan manusia akan energi listrik bisa dikatakan mendekati kebutuhan primer. Sejalan dengan hal tersebut, PLN sebagai operator listrik di Indonesia, harus menjamin keandalan pa...
PENGUJIAN DALAM PENGGUNAAN DAN DIAGNOSIS ARRESTER METAL OXIDE TANPA CELAH
PENGUJIAN DALAM PENGGUNAAN DAN DIAGNOSIS ARRESTER METAL OXIDE TANPA CELAH
This paper describes the testing strategies and risk assessment services for use in the diagnosis of metal oxide arrester without gaps that are installed substations. Different cas...
Analisa Karakteristik Arrester pada Gardu Distribusi 20 kV ST 350 Penyulang Merpati
Analisa Karakteristik Arrester pada Gardu Distribusi 20 kV ST 350 Penyulang Merpati
Arrester salah satu peralatan pada sistem tenaga listrk yang dapat melindungi peralatan listrik dari gangguan eksternal yang diakibatkan oleh tegangan lebih surja petir. Analisa ...
STUDI PENGARUH PELUAHAN PARSIAL TERHADAP PENUAAN KUALITAS MINYAK TRANSFORMATOR
STUDI PENGARUH PELUAHAN PARSIAL TERHADAP PENUAAN KUALITAS MINYAK TRANSFORMATOR
Transformator merupakan peralatan yang vital dalam sistem tenaga listrik. Apabila terjadi kerusakan pada transformator dapat menyebabkan pen yaluran listrik ke konsumen dapat terga...
Analisis Karakteristik Arus Inrush pada Transformator 3 Fasa dengan Leg yang Berbeda Berbasis Eksperimen
Analisis Karakteristik Arus Inrush pada Transformator 3 Fasa dengan Leg yang Berbeda Berbasis Eksperimen
Fenomena arus inrush merupakan kondisi transformator pada saat pertama kali dihubungkan dengan sumber tegangan dan menghasilkan lonjakan arus yang tinggi. Arus inrush dapat menyeba...