Effect of Ambient Temperature Zinc Oxide Surge Arrester Condition Monitoring
View through CrossRef
Various methods have been developed to monitor surge arrester condition and predict the probable interruption which can be caused by the failure of surge arresters. This paper aims to carry out experimental and simulation work to find the relationship between the aging level, arrester surface temperature and ambient temperature. COMSOL simulation software was used for the modeling of 120kV rated gapless ZnO surge arresters. It is observed from both the simulation analysis and experimental data that the leakage current and temperature increase as a consequence of an increase in the applied voltage across the arrester. The thermal profile of the ZnO surge arrester changes depending on the aging level and the ambient temperature. The surface temperature simulation results compare well with the experimental results, for the case of varying aging levels.
Trans Tech Publications, Ltd.
Title: Effect of Ambient Temperature Zinc Oxide Surge Arrester Condition Monitoring
Description:
Various methods have been developed to monitor surge arrester condition and predict the probable interruption which can be caused by the failure of surge arresters.
This paper aims to carry out experimental and simulation work to find the relationship between the aging level, arrester surface temperature and ambient temperature.
COMSOL simulation software was used for the modeling of 120kV rated gapless ZnO surge arresters.
It is observed from both the simulation analysis and experimental data that the leakage current and temperature increase as a consequence of an increase in the applied voltage across the arrester.
The thermal profile of the ZnO surge arrester changes depending on the aging level and the ambient temperature.
The surface temperature simulation results compare well with the experimental results, for the case of varying aging levels.
Related Results
PENGUJIAN DALAM PENGGUNAAN DAN DIAGNOSIS ARRESTER METAL OXIDE TANPA CELAH
PENGUJIAN DALAM PENGGUNAAN DAN DIAGNOSIS ARRESTER METAL OXIDE TANPA CELAH
This paper describes the testing strategies and risk assessment services for use in the diagnosis of metal oxide arrester without gaps that are installed substations. Different cas...
Effect of Ambient Temperature on Leakage Current of Gapless Metal Oxide Surge Arrester
Effect of Ambient Temperature on Leakage Current of Gapless Metal Oxide Surge Arrester
Zinc oxide (ZnO) gapless surge arresters are used for lightning and overvoltage protection in electrical power system. The leakage current monitoring is one of the well known metho...
A New Method for Calculating Zinc Content and Determining Appropriate Zinc Levels in Foods
A New Method for Calculating Zinc Content and Determining Appropriate Zinc Levels in Foods
Calculating the zinc content per 100 kcal, 100 g or 100 mL, or the reference amount customarily consumed (RACC) of food shows the zinc content of some foods inappropriately. So, ma...
Onopordum acaulon
extracts–mediated synthesis of zinc oxide nanoparticles, evaluation of cytotoxicity, and inhibitory potential of microbial biofilm and quorum sensing
Onopordum acaulon
extracts–mediated synthesis of zinc oxide nanoparticles, evaluation of cytotoxicity, and inhibitory potential of microbial biofilm and quorum sensing
Plant extracts are used as cheap and environmentally friendly complexing and stabilizing agents for the green synthesis of nanoparticle with good properties. Zinc oxide nanoparticl...
supriyatna ANALISIS KOORDINASI ISOLASI DI GARDU INDUK KUTA TERHADAP TEGANGAN LEBIH AKIBAT SAMBARAN PETIR PADA SALURAN TRANSMISI 150 KV (Pak Supriyatna)
supriyatna ANALISIS KOORDINASI ISOLASI DI GARDU INDUK KUTA TERHADAP TEGANGAN LEBIH AKIBAT SAMBARAN PETIR PADA SALURAN TRANSMISI 150 KV (Pak Supriyatna)
Sambaran petir pada saluran transmisi 150 kV dapat menimbulkan tegangan lebih yang akan membahayakan peralatan jika tegangan tersebut melampaui tingkat isolasi dasar peralatan (TID...
Analisa Karakteristik Arrester pada Gardu Distribusi 20 kV ST 350 Penyulang Merpati
Analisa Karakteristik Arrester pada Gardu Distribusi 20 kV ST 350 Penyulang Merpati
Arrester salah satu peralatan pada sistem tenaga listrk yang dapat melindungi peralatan listrik dari gangguan eksternal yang diakibatkan oleh tegangan lebih surja petir. Analisa ...
COMPARISON OF ANTIMICROBIAL EFFECT OF VARIOUS OILS MIXED WITH ZINC OXIDE – AN EX VIVO, IN VITRO STUDY
COMPARISON OF ANTIMICROBIAL EFFECT OF VARIOUS OILS MIXED WITH ZINC OXIDE – AN EX VIVO, IN VITRO STUDY
Background. Success of endodontic treatment depends on complete elimination and various factors such as the antimicrobial activity of the obturating materials. Therefore a study wa...
Studi Pengaruh Kelembapan dan Polutan pada Kinerja Isolator Arrester 20 kV
Studi Pengaruh Kelembapan dan Polutan pada Kinerja Isolator Arrester 20 kV
Arrester merupakan sebuah perangkat yang berfungsi untuk melindungi peralatan dari kegagalan dielektrik yang disebabkan oleh impuls petir, switching surge, ataupun lonjakan teganga...