Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Advanced Method of Variable Refrigerant Flow (VRF) System Design to Forecast on Site Operation—Part 3: Optimal Solutions to Minimize Sizes

View through CrossRef
Outdoor air conditioning systems (ACS) are used as autonomic systems as well as in combined outdoor and indoor ACS of the variable refrigerant flow (VRF) type, with variable speed compressors (VSC) as their advanced version. Methods for determining the optimal value of refrigeration capacity and providing the maximum rate of the summarized annual refrigeration energy generation increment, according to its needs at minimum compressor sizes and rational values, are applied to reveal the reserves for reducing the designed (installed) refrigeration capacity, thus enabling us to practically achieve maximum annual refrigeration energy generation as the primary criterion at the second stage of the general design methodology previously developed by the authors. The principle of sharing the total thermal load on the ACS between the ranges of changeable loads for outdoor air precooling, and a relatively stable load range for further processing air are used as its basis. According to this principle, the changeable thermal load range is chosen as the object for energy saving by recuperating the excessive refrigeration generated at lowered loading in order to compensate for the increased loads, thereby matching actual duties at a reduced designed refrigeration capacity. The method allows us to determine the corresponding level of regulated loads (LRL) of SRC and the load range of compressor operation to minimize sizes.
Title: Advanced Method of Variable Refrigerant Flow (VRF) System Design to Forecast on Site Operation—Part 3: Optimal Solutions to Minimize Sizes
Description:
Outdoor air conditioning systems (ACS) are used as autonomic systems as well as in combined outdoor and indoor ACS of the variable refrigerant flow (VRF) type, with variable speed compressors (VSC) as their advanced version.
Methods for determining the optimal value of refrigeration capacity and providing the maximum rate of the summarized annual refrigeration energy generation increment, according to its needs at minimum compressor sizes and rational values, are applied to reveal the reserves for reducing the designed (installed) refrigeration capacity, thus enabling us to practically achieve maximum annual refrigeration energy generation as the primary criterion at the second stage of the general design methodology previously developed by the authors.
The principle of sharing the total thermal load on the ACS between the ranges of changeable loads for outdoor air precooling, and a relatively stable load range for further processing air are used as its basis.
According to this principle, the changeable thermal load range is chosen as the object for energy saving by recuperating the excessive refrigeration generated at lowered loading in order to compensate for the increased loads, thereby matching actual duties at a reduced designed refrigeration capacity.
The method allows us to determine the corresponding level of regulated loads (LRL) of SRC and the load range of compressor operation to minimize sizes.

Related Results

Design and Engineering Economic Analysis of a Variable Refrigerant Flow (VRF) and Mini-Split Air Conditioning System
Design and Engineering Economic Analysis of a Variable Refrigerant Flow (VRF) and Mini-Split Air Conditioning System
Design and Engineering Economic Analysis of two widely used Air-Conditioning (AC) systems, Mini-Split and Variable Refrigerant Flow (VRF), in the new Engineering Complex Building u...
PERANCANGAN SISTEM KERJA SIMULATOR AC (AIR CONDITIONER) MOBIL
PERANCANGAN SISTEM KERJA SIMULATOR AC (AIR CONDITIONER) MOBIL
Sistem AC memiliki beberapa komponen yaitu kompresor, kondensor, receiver dryer, katup ekspansi dan evaporator, yang mana memiliki fungsinya tersendiri. Untuk itu perlu adanya suat...
The Improvement of Energy Efficiency in Refrigeration Systems using Ultrasonic Sensors
The Improvement of Energy Efficiency in Refrigeration Systems using Ultrasonic Sensors
Climate change is still an important issue that needs concrete support and action. Refrigerant is also one material that affects global warming and international have plans to redu...
Analisis Perbandingan Kinerja Refrigeran R134a dan MC-22 pada AC Split
Analisis Perbandingan Kinerja Refrigeran R134a dan MC-22 pada AC Split
AC (Air Conditioner) is one of the cooling machines, whose use is currently increasing. One important component that helps cooling the AC (Air Conditioner) is the refrigerant. Refr...
Analisa Pengaruh Variasi Susunan Pipa Kondensor, Masa Refrigerant, dan Kecepatan Aliran Udara Kondensor Terhadap Performa Kulkas R-600a
Analisa Pengaruh Variasi Susunan Pipa Kondensor, Masa Refrigerant, dan Kecepatan Aliran Udara Kondensor Terhadap Performa Kulkas R-600a
This study aims to analyze the effects of condenser pipe configuration, refrigerant charge, and condenser airflow velocity on the performance of a refrigerator using R-600a refrige...
Comparison between hybrid CBCT and CBCT in detection of vertical root fracture
Comparison between hybrid CBCT and CBCT in detection of vertical root fracture
Cone beam computerized tomography (CBCT) has been wildly used in many fields of dentistry, especially to investigate the vertical root fracture (VRF). CBCT systems were consisted o...

Back to Top