ANALISIS UNJUK KERJA AIR CONDITIONING (AC) SPLIT 2 PAARDE KRACHT (PK) MENGGUNAKAN REFRIGERANT 22 DENGAN MUSICOOL 22 TERHADAP KONSUMSI LISTRIK

View through CrossRef
The total use of electrical energy in a building or structure, one of them is the use of an air conditioning (AC) system. There are still many uses of air conditioning (AC) systems based on halocarbon refrigerants (R-22) in a building or structure. Refrigerant 22 is a type of halocarbon refrigerant that is widely used in Split ACs. The author conducted research on an LG 2 PK AC by replacing the refrigerant which was still based on Refrigerant 22 with the hydrocarbon refrigerant Musicool 22, then the data results were analyzed to determine the performance of the AC. From the results of the refrigerant retrofitting carried out on March 1, 2022, it was 1,715 Watts. After replacing the refrigerant type from refrigerant 22 to Musicool 22 refrigerant, the electric current dropped to 1,305 Watts in April 2022, 1,352 Watts in May 2022 and 1,346 Watts in June. so that the electrical power efficiency was obtained by 369 Watts and the percentage of electrical power savings was 21.51% compared to March 2022. An alternative to replace halocarbon-based refrigerants in the Split air conditioning (AC) system is hydrocarbon refrigerants, this is a solution in terms of using more environmentally friendly refrigerants and a small global warming effect. 
Title: ANALISIS UNJUK KERJA AIR CONDITIONING (AC) SPLIT 2 PAARDE KRACHT (PK) MENGGUNAKAN REFRIGERANT 22 DENGAN MUSICOOL 22 TERHADAP KONSUMSI LISTRIK
Description:
The total use of electrical energy in a building or structure, one of them is the use of an air conditioning (AC) system.
There are still many uses of air conditioning (AC) systems based on halocarbon refrigerants (R-22) in a building or structure.
Refrigerant 22 is a type of halocarbon refrigerant that is widely used in Split ACs.
The author conducted research on an LG 2 PK AC by replacing the refrigerant which was still based on Refrigerant 22 with the hydrocarbon refrigerant Musicool 22, then the data results were analyzed to determine the performance of the AC.
From the results of the refrigerant retrofitting carried out on March 1, 2022, it was 1,715 Watts.
After replacing the refrigerant type from refrigerant 22 to Musicool 22 refrigerant, the electric current dropped to 1,305 Watts in April 2022, 1,352 Watts in May 2022 and 1,346 Watts in June.
so that the electrical power efficiency was obtained by 369 Watts and the percentage of electrical power savings was 21.
51% compared to March 2022.
An alternative to replace halocarbon-based refrigerants in the Split air conditioning (AC) system is hydrocarbon refrigerants, this is a solution in terms of using more environmentally friendly refrigerants and a small global warming effect.
 .

Related Results

PERANCANGAN SISTEM KERJA SIMULATOR AC (AIR CONDITIONER) MOBIL
PERANCANGAN SISTEM KERJA SIMULATOR AC (AIR CONDITIONER) MOBIL
Sistem AC memiliki beberapa komponen yaitu kompresor, kondensor, receiver dryer, katup ekspansi dan evaporator, yang mana memiliki fungsinya tersendiri. Untuk itu perlu adanya suat...
Sistem Kontrol Dan Monitoring Distribusi Listrik Rumah Kos Berbasis IoT
Sistem Kontrol Dan Monitoring Distribusi Listrik Rumah Kos Berbasis IoT
Telah dilakukan perancangan prototipe sistem kontrol dan monitoring listrik berbasis IoT untuk mengatasi permasalahan ketidakseimbangan distribusi listrik di rumah kos. Masalah dis...
The Improvement of Energy Efficiency in Refrigeration Systems using Ultrasonic Sensors
The Improvement of Energy Efficiency in Refrigeration Systems using Ultrasonic Sensors
Climate change is still an important issue that needs concrete support and action. Refrigerant is also one material that affects global warming and international have plans to redu...
Air-Conditioning Using Waste Heat Energy
Air-Conditioning Using Waste Heat Energy
Abstract All oil & gas building facilities such as control room, electrical room, substation and personal accommodation etc., require a comfortable indoor condit...
MANAJEMEN PEMAKAIAN PULSA LISTRIK PELANGGAN METER PRABAYAR
MANAJEMEN PEMAKAIAN PULSA LISTRIK PELANGGAN METER PRABAYAR
Salah satu kekurangan sistem kWh meter digital prabayar adalah tidak dapat melakukan pemantauan pemakaian energi listrik secara real time, sehingga token listrik habis sebelum wakt...
Model Hybrid Pembangkit Listrik Di Pedesaan
Model Hybrid Pembangkit Listrik Di Pedesaan
Energi listrik merupakan salah satu jenis energi yang paling banyak digunakan dalam aktivitas manusia sehari-hari. pemenuhan kebutuhan energi listrik dapat meningkatkan kesejahtera...
PERANAN SUASANA KERJA TERHADAP KEINGINAN PINDAH KERJA PADA KARYAWAN PT HASNUR JAYA UTAMA
PERANAN SUASANA KERJA TERHADAP KEINGINAN PINDAH KERJA PADA KARYAWAN PT HASNUR JAYA UTAMA
Penelitian ini bertujuan untuk mengetahui ada tidaknya peranan suasana kerja terhadap keinginan pindah kerja karyawan. Populasi pada penelitian ini yaitu seluruh karyawan PT. Hasnu...
PENGARUH JENIS REFRIGERANT DAN DIAMETER PIPA KAPILER TERHADAP KINERJA AC SPLIT
PENGARUH JENIS REFRIGERANT DAN DIAMETER PIPA KAPILER TERHADAP KINERJA AC SPLIT
Refrigerant R-22 yang dipakai untuk AC sangat berperan besar dalam proses penipisan lapisan ozon dan pemanasan global, sehingga mulai dilarang pemakaiannya. R-32 dan R-410A merupak...

Back to Top