Analisis Perbandingan Kinerja Refrigeran R134a dan MC-22 pada AC Split

View through CrossRef
AC (Air Conditioner) is one of the cooling machines, whose use is currently increasing. One important component that helps cooling the AC (Air Conditioner) is the refrigerant. Refrigerant is a kind of material or substance in the form of liquid and gas which is usually flowed in the refrigeration machine installation. The purpose of this study was to determine the performance (COP), electrical energy consumption, and cooling rate from the use of refrigerants R134a and MC-22. The independent variables in this research are refrigerant R134a and refrigerant MC-22. The dependent variable in this study is COP (Coefficient of Performance), electrical energy consumption, and cooling rate. The control variable in this study was using time variations. The research material is refrigerant R134a and MC-22 The results of this study showed that R134a refrigerant has a better COP value than MC-22 refrigerant, where the COP value at 60 minutes for R134a refrigerant is 8.6 while for MC-22 refrigerant is 8.0. At 60 minutes the use of refrigerant R134a, the electrical energy used is 385.00 W.h. Meanwhile, 60 minutes of the use of refrigerant MC-22, the electrical energy used is 455.40 W.h.
Title: Analisis Perbandingan Kinerja Refrigeran R134a dan MC-22 pada AC Split
Description:
AC (Air Conditioner) is one of the cooling machines, whose use is currently increasing.
One important component that helps cooling the AC (Air Conditioner) is the refrigerant.
Refrigerant is a kind of material or substance in the form of liquid and gas which is usually flowed in the refrigeration machine installation.
The purpose of this study was to determine the performance (COP), electrical energy consumption, and cooling rate from the use of refrigerants R134a and MC-22.
The independent variables in this research are refrigerant R134a and refrigerant MC-22.
The dependent variable in this study is COP (Coefficient of Performance), electrical energy consumption, and cooling rate.
The control variable in this study was using time variations.
The research material is refrigerant R134a and MC-22 The results of this study showed that R134a refrigerant has a better COP value than MC-22 refrigerant, where the COP value at 60 minutes for R134a refrigerant is 8.
6 while for MC-22 refrigerant is 8.
At 60 minutes the use of refrigerant R134a, the electrical energy used is 385.
00 W.
h.
Meanwhile, 60 minutes of the use of refrigerant MC-22, the electrical energy used is 455.
40 W.
h.

Related Results

FAKTOR-FAKTOR YANG MEMPENGARUHI MORTALITAS PADA PASIEN DENGAN FRAKTUR COSTA: Literature Review
FAKTOR-FAKTOR YANG MEMPENGARUHI MORTALITAS PADA PASIEN DENGAN FRAKTUR COSTA: Literature Review
FAKTOR-FAKTOR YANG MEMPENGARUHI MORTALITAS PADA PASIEN DENGAN FRAKTUR COSTA: Literature  Review Anna Tri Wahyuni1), Masfuri2),  Liya Arista3)1,2,3 Fakultas Ilmu Keperawatan Univers...
KECEMASAN SAAT PANDEMI COVID 19: LITERATUR REVIEW Hardiyati, Efri Widianti, Taty Hernawaty Departemen Keperawatan Jiwa Poltekkes Kemenkes Mamuju Sulbar, Universitas Pad...
ENERGY PERFORMANCE ANALYSIS OF R32 AND R134A REFRIGERANT FOR SPRING POOL WATER HEATER
ENERGY PERFORMANCE ANALYSIS OF R32 AND R134A REFRIGERANT FOR SPRING POOL WATER HEATER
For a country with a tropical climate, such as Indonesia, heat pump technologies are usually necessary in high-altitude regions, where the temperatures tend to be cooler, such as a...
DAMPAK TEKNOLOGI TERHADAP PROSES BELAJAR MENGAJAR
DAMPAK TEKNOLOGI TERHADAP PROSES BELAJAR MENGAJAR
DAFTAR PUSTAKAAditama, M. H. R., & Selfiardy, S. (2022). Kehidupan Mahasiswa Kuliah Sambil Bekerja di Masa Pandemi Covid-19. Kidspedia: Jurnal Pendidikan Anak Usia Dini, 3(...
PENERAPAN E-KINERJA DI DINAS PERDAGANGAN KOTA SURAKARTA
PENERAPAN E-KINERJA DI DINAS PERDAGANGAN KOTA SURAKARTA
<p>Penelitan ini bertujuan untuk mengetahui penerapan sistem Elektronik-Kinerja (e-kinerja) di Dinas Perdagangan kota Surakarta serta untuk mengetahui kendala dan solusi dari...
ANALISIS PENGGUNAAN REFRIGERANT HYDROCARBON TERHADAP UNJUK KERJA MESIN PENDINGIN TIPE AC SPLIT
ANALISIS PENGGUNAAN REFRIGERANT HYDROCARBON TERHADAP UNJUK KERJA MESIN PENDINGIN TIPE AC SPLIT
Kebutuhan akan refrigeran ramah lingkungan semakin meningkat seiring isu pemanasan global serta keterbatasan refrigeran hidrofluorocarbon (HFC) yang memiliki nilai Global Warming P...
PENGARUH MOTIVASI INTRINSIK DAN EKTRINSIK TERHADAP KINERJA KARYAWAN KOPERASI SYARIAH DI KALIBARU
PENGARUH MOTIVASI INTRINSIK DAN EKTRINSIK TERHADAP KINERJA KARYAWAN KOPERASI SYARIAH DI KALIBARU
Keberhasilan sebuah perusahaan sangat erat kaitannya dengan kinerja karyawan yang ada di dalamnya. Karyawan merupakan penggerak dan pengendali dalam perusahaan. Meningkatnya kinerj...

Back to Top