The Improvement of Energy Efficiency in Refrigeration Systems using Ultrasonic Sensors
View through CrossRef
Climate change is still an important issue that needs concrete support and action. Refrigerant is also one material that affects global warming and international have plans to reduce the use of HFC refrigerants. Thailand also uses R404A refrigerant, which is an HFC refrigerant with a GWP of up to 3,129 and Thailand plans to reduce its use by 15% in 2030. R404A is the most widely used HFC refrigerant today because it can be used in both refrigeration and air conditioning systems. In the refrigeration system, which uses about 1 ton of refrigerant, when a leak occurs, in addition to affecting global warming and maintenance costs, it also affects the energy consumption of the refrigeration system. From data on the amount of refrigerant used in 2022, it was found that the use of refrigerant for maintenance is 25 tons, averaging 2 tons per month. This research will present the optimization of the maintenance refrigeration system by decreasing carbon emissions using ultrasonic sensors to keep the refrigerant level. The ultrasonic detects flat gas in refrigeration systems, which can detect fluid leaks rather than leaks. detector or using a sight glass. The results of the research found that when the refrigerant leak can be fixed quickly, it will save the use of refrigerant and help reduce energy. When fixing a leaking refrigerant system, 1) 10% will reduce energy by 7%. 2) 20% will reduce energy by 17% 3) 30% will reduce energy by 59%. This system will be able to be expanded to other stores and air conditioning systems in the future.
Title: The Improvement of Energy Efficiency in Refrigeration Systems using Ultrasonic Sensors
Description:
Climate change is still an important issue that needs concrete support and action.
Refrigerant is also one material that affects global warming and international have plans to reduce the use of HFC refrigerants.
Thailand also uses R404A refrigerant, which is an HFC refrigerant with a GWP of up to 3,129 and Thailand plans to reduce its use by 15% in 2030.
R404A is the most widely used HFC refrigerant today because it can be used in both refrigeration and air conditioning systems.
In the refrigeration system, which uses about 1 ton of refrigerant, when a leak occurs, in addition to affecting global warming and maintenance costs, it also affects the energy consumption of the refrigeration system.
From data on the amount of refrigerant used in 2022, it was found that the use of refrigerant for maintenance is 25 tons, averaging 2 tons per month.
This research will present the optimization of the maintenance refrigeration system by decreasing carbon emissions using ultrasonic sensors to keep the refrigerant level.
The ultrasonic detects flat gas in refrigeration systems, which can detect fluid leaks rather than leaks.
detector or using a sight glass.
The results of the research found that when the refrigerant leak can be fixed quickly, it will save the use of refrigerant and help reduce energy.
When fixing a leaking refrigerant system, 1) 10% will reduce energy by 7%.
2) 20% will reduce energy by 17% 3) 30% will reduce energy by 59%.
This system will be able to be expanded to other stores and air conditioning systems in the future.
Related Results
Modern refrigeration solutions for maritime sector and marine refrigeration transport
Modern refrigeration solutions for maritime sector and marine refrigeration transport
New coming environmental regulations from International Maritime Organization put each involved actor from ship manager, ship owner to cargo owner into a hard situation for a short...
METHOD FOR EVALUATING EFFICIENCY OF REFRIGERATION UNITS BASED ON SINGLE-STAGE COMPRESSION CYCLE
METHOD FOR EVALUATING EFFICIENCY OF REFRIGERATION UNITS BASED ON SINGLE-STAGE COMPRESSION CYCLE
The development of automation and programming tools is one of the priority areas determined by the State Program "National Technology Initiative," which requires the development of...
Refrigeration
Refrigeration
Abstract
This chapter focuses primarily on refrigeration applications, which cover such diverse uses as food processing and storage, supermarket display cases, skating ri...
Energy Performance Benchmarking of Process Refrigeration Units
Energy Performance Benchmarking of Process Refrigeration Units
Abstract
Process refrigeration units are one of the major energy consumers at gas processing plants. Owing to the higher energy consumption, evaluation and benchmark...
Erratum in: "Lyudmila D. Akimova (11.08.1929–12.09.2022)"
Erratum in: "Lyudmila D. Akimova (11.08.1929–12.09.2022)"
There was a mistake in the obituary "Lyudmila D. Akimova (11.08.192912.09.2022)" published in 'Refrigeration Technology'2022;111(2) doi: 10.17816/RF112047. Previously published tex...
Specific Consumption Analysis of Vapor Compression Refrigeration System
Specific Consumption Analysis of Vapor Compression Refrigeration System
In real life applications the latest findings of energy savings are playing important role for optimizing and improving the systems. Vapor compression refrigeration systems are som...
Effects of Ultrasonic Waves During Waterflooding for Enhanced Oil Recovery
Effects of Ultrasonic Waves During Waterflooding for Enhanced Oil Recovery
Ultrasonic waves is an unconventional enhanced oil recovery (EOR) technology and has been a point of interest as it is more economical and environmentally friendly. Numerous resear...
A review on solar photovoltaic-powered thermoelectric coolers, performance enhancements, and recent advances
A review on solar photovoltaic-powered thermoelectric coolers, performance enhancements, and recent advances
Abstract
The average global temperature has increased by approximately 0.7 °C since the last century. If the current trend continues, the temperature may further increase by 1.4 – ...