Advanced Method of Variable Refrigerant Flow (VRF) Systems Designing to Forecast On-Site Operation—Part 1: General Approaches and Criteria
View through CrossRef
All the energetic management and controlling strategies in ambient air conditioning systems (ACS) are aimed to match design load to current needs. This might be achieved by determining a rational value of design thermal load without overestimation that can minimize its deviation from the actual values. The application of variable refrigerant flow (VRF) systems with speed-regulated compressors (SRC) is considered as the most advanced trend in building air conditioning due to the ability of SRCs to cover changeable heat loads without lowering their efficiency. The level of load regulation by SRC is evaluated as the ratio of the load range, regulated by SCR, to the overall design load range. With this, the range of actual changeable loads is usually supposed to be covered by SRC entirely while keeping the rest, unregulated, and load range unchangeable. However, to confirm this, the rest load range behind the regulated one should be investigated to estimate the efficiency of SRC operation. Therefore, the approach to dividing the overall thermal load range of ambient air conditioning into the ranges of changeable and unchangeable loads to compare with those covered by SRC is used. From this approach, the method of rational designing and shearing a design refrigeration capacity in response to current loading, based on the principle of two-stage ambient air conditioning, has been widened on the VRF systems to estimate the efficiency of SCR application. This was realized by imposing the load ranges regulated by SRC onto the ranges of changeable and unchangeable loads within the overall range of actual loading. The proposed innovative criteria and indicators for rational shearing the load ranges to match current duties and load level evaluation can reveal the reserves for improving the efficiency of SRC compressor operation and the ACS of VRF type as a whole.
Title: Advanced Method of Variable Refrigerant Flow (VRF) Systems Designing to Forecast On-Site Operation—Part 1: General Approaches and Criteria
Description:
All the energetic management and controlling strategies in ambient air conditioning systems (ACS) are aimed to match design load to current needs.
This might be achieved by determining a rational value of design thermal load without overestimation that can minimize its deviation from the actual values.
The application of variable refrigerant flow (VRF) systems with speed-regulated compressors (SRC) is considered as the most advanced trend in building air conditioning due to the ability of SRCs to cover changeable heat loads without lowering their efficiency.
The level of load regulation by SRC is evaluated as the ratio of the load range, regulated by SCR, to the overall design load range.
With this, the range of actual changeable loads is usually supposed to be covered by SRC entirely while keeping the rest, unregulated, and load range unchangeable.
However, to confirm this, the rest load range behind the regulated one should be investigated to estimate the efficiency of SRC operation.
Therefore, the approach to dividing the overall thermal load range of ambient air conditioning into the ranges of changeable and unchangeable loads to compare with those covered by SRC is used.
From this approach, the method of rational designing and shearing a design refrigeration capacity in response to current loading, based on the principle of two-stage ambient air conditioning, has been widened on the VRF systems to estimate the efficiency of SCR application.
This was realized by imposing the load ranges regulated by SRC onto the ranges of changeable and unchangeable loads within the overall range of actual loading.
The proposed innovative criteria and indicators for rational shearing the load ranges to match current duties and load level evaluation can reveal the reserves for improving the efficiency of SRC compressor operation and the ACS of VRF type as a whole.
Related Results
Design and Engineering Economic Analysis of a Variable Refrigerant Flow (VRF) and Mini-Split Air Conditioning System
Design and Engineering Economic Analysis of a Variable Refrigerant Flow (VRF) and Mini-Split Air Conditioning System
Design and Engineering Economic Analysis of two widely used Air-Conditioning (AC) systems, Mini-Split and Variable Refrigerant Flow (VRF), in the new Engineering Complex Building u...
PERANCANGAN SISTEM KERJA SIMULATOR AC (AIR CONDITIONER) MOBIL
PERANCANGAN SISTEM KERJA SIMULATOR AC (AIR CONDITIONER) MOBIL
Sistem AC memiliki beberapa komponen yaitu kompresor, kondensor, receiver dryer, katup ekspansi dan evaporator, yang mana memiliki fungsinya tersendiri. Untuk itu perlu adanya suat...
The Improvement of Energy Efficiency in Refrigeration Systems using Ultrasonic Sensors
The Improvement of Energy Efficiency in Refrigeration Systems using Ultrasonic Sensors
Climate change is still an important issue that needs concrete support and action. Refrigerant is also one material that affects global warming and international have plans to redu...
Analisis Perbandingan Kinerja Refrigeran R134a dan MC-22 pada AC Split
Analisis Perbandingan Kinerja Refrigeran R134a dan MC-22 pada AC Split
AC (Air Conditioner) is one of the cooling machines, whose use is currently increasing. One important component that helps cooling the AC (Air Conditioner) is the refrigerant. Refr...
Analisa Pengaruh Variasi Susunan Pipa Kondensor, Masa Refrigerant, dan Kecepatan Aliran Udara Kondensor Terhadap Performa Kulkas R-600a
Analisa Pengaruh Variasi Susunan Pipa Kondensor, Masa Refrigerant, dan Kecepatan Aliran Udara Kondensor Terhadap Performa Kulkas R-600a
This study aims to analyze the effects of condenser pipe configuration, refrigerant charge, and condenser airflow velocity on the performance of a refrigerator using R-600a refrige...
Comparison between hybrid CBCT and CBCT in detection of vertical root fracture
Comparison between hybrid CBCT and CBCT in detection of vertical root fracture
Cone beam computerized tomography (CBCT) has been wildly used in many fields of dentistry, especially to investigate the vertical root fracture (VRF). CBCT systems were consisted o...
ANALISIS UNJUK KERJA AIR CONDITIONING (AC) SPLIT 2 PAARDE KRACHT (PK) MENGGUNAKAN REFRIGERANT 22 DENGAN MUSICOOL 22 TERHADAP KONSUMSI LISTRIK
ANALISIS UNJUK KERJA AIR CONDITIONING (AC) SPLIT 2 PAARDE KRACHT (PK) MENGGUNAKAN REFRIGERANT 22 DENGAN MUSICOOL 22 TERHADAP KONSUMSI LISTRIK
The total use of electrical energy in a building or structure, one of them is the use of an air conditioning (AC) system. There are still many uses of air conditioning (AC) systems...
Correction method by introducing cloud cover forecast factor in model temperature forecast
Correction method by introducing cloud cover forecast factor in model temperature forecast
Objective temperature forecast products can achieve better forecast quality by using one-dimensional regression correction directly based on the present model temperature forecast ...