Design and Engineering Economic Analysis of a Variable Refrigerant Flow (VRF) and Mini-Split Air Conditioning System

View through CrossRef
Design and Engineering Economic Analysis of two widely used Air-Conditioning (AC) systems, Mini-Split and Variable Refrigerant Flow (VRF), in the new Engineering Complex Building under the same indoor and outdoor conditions for an entire year is carried out by using Carrier Hourly Analysis Program software for cooling load estimation, and the Net Present Worth Analysis for Economic Analysis of both systems. Both systems are direct expansion air conditioning systems; hence the cooling load estimation was done using the ASHRAE transfer function method embedded within the Carrier software. Equipment to be used in analysis were selected from the Toshiba selection catalogues (Mini Split system), while that for the VRF system was selected using Toshiba simulation software. The annual energy analysis of both systems indicated that the VRF system will require more energy to run on an annual basis than the Mini Split system. However, the analysis was carried out without considering the part load potential energy savings of the VRF system. Net Present Worth Analysis carried out also favoured the Mini Split system in terms of Net Present Value of the systems. Based on the Engineering Economic Analysis carried out on the two systems, the overall Net Present Value for the VRF system is N77,891,808.66, while that of the Mini-Split system is N46,641,828.74. This result shows that the VRF system has a higher cost implication than the Mini-Split system. Hence, in terms of cost, the Mini-Split system is a more viable option.
Title: Design and Engineering Economic Analysis of a Variable Refrigerant Flow (VRF) and Mini-Split Air Conditioning System
Description:
Design and Engineering Economic Analysis of two widely used Air-Conditioning (AC) systems, Mini-Split and Variable Refrigerant Flow (VRF), in the new Engineering Complex Building under the same indoor and outdoor conditions for an entire year is carried out by using Carrier Hourly Analysis Program software for cooling load estimation, and the Net Present Worth Analysis for Economic Analysis of both systems.
Both systems are direct expansion air conditioning systems; hence the cooling load estimation was done using the ASHRAE transfer function method embedded within the Carrier software.
Equipment to be used in analysis were selected from the Toshiba selection catalogues (Mini Split system), while that for the VRF system was selected using Toshiba simulation software.
The annual energy analysis of both systems indicated that the VRF system will require more energy to run on an annual basis than the Mini Split system.
However, the analysis was carried out without considering the part load potential energy savings of the VRF system.
Net Present Worth Analysis carried out also favoured the Mini Split system in terms of Net Present Value of the systems.
Based on the Engineering Economic Analysis carried out on the two systems, the overall Net Present Value for the VRF system is N77,891,808.
66, while that of the Mini-Split system is N46,641,828.
74.
This result shows that the VRF system has a higher cost implication than the Mini-Split system.
Hence, in terms of cost, the Mini-Split system is a more viable option.

Related Results

Air-Conditioning Using Waste Heat Energy
Air-Conditioning Using Waste Heat Energy
Abstract All oil & gas building facilities such as control room, electrical room, substation and personal accommodation etc., require a comfortable indoor condit...
Comparison between hybrid CBCT and CBCT in detection of vertical root fracture
Comparison between hybrid CBCT and CBCT in detection of vertical root fracture
Cone beam computerized tomography (CBCT) has been wildly used in many fields of dentistry, especially to investigate the vertical root fracture (VRF). CBCT systems were consisted o...
Solar Powered Air-Conditioning Using Absorption Refrigeration Technique
Solar Powered Air-Conditioning Using Absorption Refrigeration Technique
The present work includes design, construction and operates of a prototype solar absorption refrigeration system, using methanol as a refrigerant to avoid any refrigerant that caus...
Hybrid system development and application research for refrigerant leak inspection
Hybrid system development and application research for refrigerant leak inspection
Recently, record-breaking heatwaves due to global warming and abnormal weather have occurred in the summer, and sales and usage of air conditioners are rapidly increasing. Air co...
STRUKTUR DRAMATIK PERTUNJUKAN DRAMA KLASIK SANGGAR TEATER MINI LAKON DEWA RUCI KAJIAN BENTUK DAN FUNGSI
STRUKTUR DRAMATIK PERTUNJUKAN DRAMA KLASIK SANGGAR TEATER MINI LAKON DEWA RUCI KAJIAN BENTUK DAN FUNGSI
ABSTRAK   Pada dasarnya nilai pendidikan karakter mempunyai tiga bagian yang saling bekaitan, yaitu pengetahuan moral, penghayatan moral dan perilaku moral. Oleh karena...
Study of variable refrigerant flow systems: an alternative to traditional air conditioning
Study of variable refrigerant flow systems: an alternative to traditional air conditioning
Variable refrigerant flow systems offer significant advantages over traditional air conditioning systems. They enable individual temperature control for each indoor unit, providing...
Refrigerant Subcooling Correlations for Different Expansion Devices for a Non-Intrusive Charge Indicator
Refrigerant Subcooling Correlations for Different Expansion Devices for a Non-Intrusive Charge Indicator
The most common problems affecting residential and light commercial heating, ventilation, and air-conditioning (HVAC) systems are slow refrigerant leaks. Equipment users are usuall...

Back to Top