Javascript must be enabled to continue!
Performance Investigation of an Eco-Friendly Refrigerant Mixture as an Alternative to R290/R600a
View through CrossRef
R134a is the most widely used refrigerant in domestic refrigerators. It must be phased out soon according to Kyoto protocol due to its high global warming potential (GWP) of 1300. It has been proposed that by previous experimental investigations, R290/R600a is the best alternate ozone friendly refrigerant mixture for R134a. But due to its high flammability this mixture is not completely substituted as an alternate working fluid in our country. In the present work, performance investigation has been made with eco-friendly refrigerant mixture (composed of R123 and R290 in the ratio of 70:30 by weight) in a refrigerator. This mixture has a very low ozone depletion potential (ODP) and has zero GWP value. Also this mixture has low flammability index when compared with R290/R600a. Continuous running tests were performed under different ambient temperatures (23°C, 28°C, 32°C and 36°C).The ON OFF and DOOR OPEN test results showed that ON TIME percentage of the compressor for the mixture (HCFC123/HC290) is less than that for HCM (R290/R600a). Also the power consumed by mixture (HCFC123/HC290) is lesser by 15% than that of R290/R600a and due to its low flammability property it can be a valuable replacement for the R290/R600a refrigerant mixture.
Title: Performance Investigation of an Eco-Friendly Refrigerant Mixture as an Alternative to R290/R600a
Description:
R134a is the most widely used refrigerant in domestic refrigerators.
It must be phased out soon according to Kyoto protocol due to its high global warming potential (GWP) of 1300.
It has been proposed that by previous experimental investigations, R290/R600a is the best alternate ozone friendly refrigerant mixture for R134a.
But due to its high flammability this mixture is not completely substituted as an alternate working fluid in our country.
In the present work, performance investigation has been made with eco-friendly refrigerant mixture (composed of R123 and R290 in the ratio of 70:30 by weight) in a refrigerator.
This mixture has a very low ozone depletion potential (ODP) and has zero GWP value.
Also this mixture has low flammability index when compared with R290/R600a.
Continuous running tests were performed under different ambient temperatures (23°C, 28°C, 32°C and 36°C).
The ON OFF and DOOR OPEN test results showed that ON TIME percentage of the compressor for the mixture (HCFC123/HC290) is less than that for HCM (R290/R600a).
Also the power consumed by mixture (HCFC123/HC290) is lesser by 15% than that of R290/R600a and due to its low flammability property it can be a valuable replacement for the R290/R600a refrigerant mixture.
Related Results
Molecular-scale investigation of the impact of surface temperature on the heterogeneous condensation of superheated R600a vapor refrigerant within a microchannel
Molecular-scale investigation of the impact of surface temperature on the heterogeneous condensation of superheated R600a vapor refrigerant within a microchannel
In the domestic refrigeration system, superheated vapor phase R600a refrigerant is condensed in a cooled capillary tube. The microscopic process of the heterogeneous condensation o...
Analisis Kinerja R290 sebagai Pengganti R32 pada Unit AC-Split Kapasitas 9,000 Btuh/hr
Analisis Kinerja R290 sebagai Pengganti R32 pada Unit AC-Split Kapasitas 9,000 Btuh/hr
R290 is a type of natural refrigerant that has ODP = 0 and GWP = 4. While R32 from synthetic materials has ODP= 0 and GWP = 675 both are refrigerants used in Split AC. With this hi...
PERANCANGAN SISTEM KERJA SIMULATOR AC (AIR CONDITIONER) MOBIL
PERANCANGAN SISTEM KERJA SIMULATOR AC (AIR CONDITIONER) MOBIL
Sistem AC memiliki beberapa komponen yaitu kompresor, kondensor, receiver dryer, katup ekspansi dan evaporator, yang mana memiliki fungsinya tersendiri. Untuk itu perlu adanya suat...
The Use of R290 As a Replacement For R404A in Block Ice Machines
The Use of R290 As a Replacement For R404A in Block Ice Machines
This study evaluates the performance of R290 refrigerant as an alternative to R404A in block ice-making machines based on vapor compression cycles. The method used is a quantitativ...
Physical Property Calculation and Refrigeration Cycle Analysis of Mixed Refrigerant R32/R290
Physical Property Calculation and Refrigeration Cycle Analysis of Mixed Refrigerant R32/R290
The adoption of eco-friendly refrigerants in air conditioning systems is crucial for advancing low-carbon architecture. The current refrigerant R410A, with its high global warming ...
Analisis Perbandingan Kinerja Refrigeran R134a dan MC-22 pada AC Split
Analisis Perbandingan Kinerja Refrigeran R134a dan MC-22 pada AC Split
AC (Air Conditioner) is one of the cooling machines, whose use is currently increasing. One important component that helps cooling the AC (Air Conditioner) is the refrigerant. Refr...
The Improvement of Energy Efficiency in Refrigeration Systems using Ultrasonic Sensors
The Improvement of Energy Efficiency in Refrigeration Systems using Ultrasonic Sensors
Climate change is still an important issue that needs concrete support and action. Refrigerant is also one material that affects global warming and international have plans to redu...
ANALISIS UNJUK KERJA AIR CONDITIONING (AC) SPLIT 2 PAARDE KRACHT (PK) MENGGUNAKAN REFRIGERANT 22 DENGAN MUSICOOL 22 TERHADAP KONSUMSI LISTRIK
ANALISIS UNJUK KERJA AIR CONDITIONING (AC) SPLIT 2 PAARDE KRACHT (PK) MENGGUNAKAN REFRIGERANT 22 DENGAN MUSICOOL 22 TERHADAP KONSUMSI LISTRIK
The total use of electrical energy in a building or structure, one of them is the use of an air conditioning (AC) system. There are still many uses of air conditioning (AC) systems...