Analisis Kinerja R290 sebagai Pengganti R32 pada Unit AC-Split Kapasitas 9,000 Btuh/hr
View through CrossRef
R290 is a type of natural refrigerant that has ODP = 0 and GWP = 4. While R32 from synthetic materials has ODP= 0 and GWP = 675 both are refrigerants used in Split AC. With this high GWP, it can have a damaging impact on the atmosphere. The advantage of R290 is that it has a lower density compared to R32, which can save the number of fillings in the AC unit by ±30% of the previous amount of refrigerant in the same volume. R290/R32 was flammable with LFL= 2%/13% and UFL= 10%/33%. The purpose of this study was to analyze the performance of R290 as a substitute for R32 on an AC-split unit with a capacity of 9,000 Btuh/hr. The steps used in the test are that the AC unit is placed in an open room with ambient temperature around 32°/80°C. The test was carried out until it reaches the optimal and stable temperature, then data is collected. The results of data collection from the evaporator air temperature R290/R32 = 21.4°C/23.0°C, condenser air temperature = R290/R32= 35°C/38.5°C, suction pressure= 90 psig/130 psig and discharge 200 psig/420 psig. The test data were analyzed and calculated using the Mollier Chart software with the results = R290/R32 = refrigeration effect = 344.8/272.2 kJ/kg, compression work = 12.18/13.02 kJ/kg, COP = 28.3/20.9, compression ratio = 2.2/3.2, strong electric current 4.98/5.73 A. From the decrease in electric current of R290 obtained a savings of 13.3% was obtained when converted to electricity bill payment and get a profit of 45,886/month.
Title: Analisis Kinerja R290 sebagai Pengganti R32 pada Unit AC-Split Kapasitas 9,000 Btuh/hr
Description:
R290 is a type of natural refrigerant that has ODP = 0 and GWP = 4.
While R32 from synthetic materials has ODP= 0 and GWP = 675 both are refrigerants used in Split AC.
With this high GWP, it can have a damaging impact on the atmosphere.
The advantage of R290 is that it has a lower density compared to R32, which can save the number of fillings in the AC unit by ±30% of the previous amount of refrigerant in the same volume.
R290/R32 was flammable with LFL= 2%/13% and UFL= 10%/33%.
The purpose of this study was to analyze the performance of R290 as a substitute for R32 on an AC-split unit with a capacity of 9,000 Btuh/hr.
The steps used in the test are that the AC unit is placed in an open room with ambient temperature around 32°/80°C.
The test was carried out until it reaches the optimal and stable temperature, then data is collected.
The results of data collection from the evaporator air temperature R290/R32 = 21.
4°C/23.
0°C, condenser air temperature = R290/R32= 35°C/38.
5°C, suction pressure= 90 psig/130 psig and discharge 200 psig/420 psig.
The test data were analyzed and calculated using the Mollier Chart software with the results = R290/R32 = refrigeration effect = 344.
8/272.
2 kJ/kg, compression work = 12.
18/13.
02 kJ/kg, COP = 28.
3/20.
9, compression ratio = 2.
2/3.
2, strong electric current 4.
98/5.
73 A.
From the decrease in electric current of R290 obtained a savings of 13.
3% was obtained when converted to electricity bill payment and get a profit of 45,886/month.
Related Results
ANALISIS SUBSTANSI PIDANA UANG PENGGANTI DALAM KASUS TINDAK PIDANA KORUPSI
ANALISIS SUBSTANSI PIDANA UANG PENGGANTI DALAM KASUS TINDAK PIDANA KORUPSI
Pasal 18 Undang-undang Nomor 31 Tahun 1999 tentang Pemberantasan Tindak Pidana Korupsi jo. Undang-undang Nomor 20 Tahun 2001 tentang Perubahan Atas UU Nomor 31 Tahun 1999 menyebut...
PERAN TATA KELOLA PERUSAHAAN DALAM MEMODERASI PENGARUH IMPLEMANTASI GREEN ACCOUNTING, CORPORATE SOCIAL RESPONSIBILITY DAN FIRM SIZE TERHADAP KINERJA KEUANGAN
PERAN TATA KELOLA PERUSAHAAN DALAM MEMODERASI PENGARUH IMPLEMANTASI GREEN ACCOUNTING, CORPORATE SOCIAL RESPONSIBILITY DAN FIRM SIZE TERHADAP KINERJA KEUANGAN
This study examines the role of corporate governance in moderating the influence of green accounting disclosure, corporate social responsibility (CSR), and firm size on the financi...
ENERGY PERFORMANCE ANALYSIS OF R32 AND R134A REFRIGERANT FOR SPRING POOL WATER HEATER
ENERGY PERFORMANCE ANALYSIS OF R32 AND R134A REFRIGERANT FOR SPRING POOL WATER HEATER
For a country with a tropical climate, such as Indonesia, heat pump technologies are usually necessary in high-altitude regions, where the temperatures tend to be cooler, such as a...
Experimental Study of Performance Analysis of Split Air Conditioning Unit by Replacing Refrigerant R410A with R32 and R290
Experimental Study of Performance Analysis of Split Air Conditioning Unit by Replacing Refrigerant R410A with R32 and R290
The world phasedown of high global warming potential (GWP) refrigerants has created a need for low-GWP replacements that have equal or better performance in air conditioning system...
Pano Klimalarında Farklı Soğutucu Akışkan Kullanımının Analizi
Pano Klimalarında Farklı Soğutucu Akışkan Kullanımının Analizi
Çalışma sürecinde, küresel beklenti ve taleplerin sürekli değişerek güncellendiği iklimlendirme sistemlerindeki soğutucu akışkan kullanımı çevresel ve termal faktörlerce irdelenere...
Analisis Rasio Kompresi AC Split R32 yang Diretrofit R290 di Ruang Akomodasi Kapal
Analisis Rasio Kompresi AC Split R32 yang Diretrofit R290 di Ruang Akomodasi Kapal
Air conditioning (AC) systems play a crucial role in maintaining thermal comfort within ship accommodation spaces, especially during operations in tropical climates. However, the u...
Physical Property Calculation and Refrigeration Cycle Analysis of Mixed Refrigerant R32/R290
Physical Property Calculation and Refrigeration Cycle Analysis of Mixed Refrigerant R32/R290
The adoption of eco-friendly refrigerants in air conditioning systems is crucial for advancing low-carbon architecture. The current refrigerant R410A, with its high global warming ...
Performance Investigation of an Eco-Friendly Refrigerant Mixture as an Alternative to R290/R600a
Performance Investigation of an Eco-Friendly Refrigerant Mixture as an Alternative to R290/R600a
R134a is the most widely used refrigerant in domestic refrigerators. It must be phased out soon according to Kyoto protocol due to its high global warming potential (GWP) of 1300. ...