Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Analisis Rasio Kompresi AC Split R32 yang Diretrofit R290 di Ruang Akomodasi Kapal

View through CrossRef
Air conditioning (AC) systems play a crucial role in maintaining thermal comfort within ship accommodation spaces, especially during operations in tropical climates. However, the use of refrigerants such as R32 raises environmental concerns due to its relatively high Global Warming Potential (GWP). This study aims to analyze the impact of retrofitting 40% by mass of R290 into a 1-HP split AC system originally designed for R32, focusing on the resulting compression ratio and cooling performance. The experimental method involved varying the inlet air temperatures to the evaporator (23°C, 25°C, and 27°C) and condenser (30°C and 35°C). Suction and discharge pressures of the compressor were measured to calculate the compression ratio. The results showed that R32 yielded the highest compression ratio of 3.09 and the lowest at 2.87, while R290 produced a maximum of 2.86 and a minimum of 2.60. These differences reflect the influence of each refrigerant’s thermodynamic properties on compressor operation. R290 demonstrates potential as an environmentally friendly alternative for marine air conditioning systems, although technical adjustments are required to maintain optimal system performance.
Title: Analisis Rasio Kompresi AC Split R32 yang Diretrofit R290 di Ruang Akomodasi Kapal
Description:
Air conditioning (AC) systems play a crucial role in maintaining thermal comfort within ship accommodation spaces, especially during operations in tropical climates.
However, the use of refrigerants such as R32 raises environmental concerns due to its relatively high Global Warming Potential (GWP).
This study aims to analyze the impact of retrofitting 40% by mass of R290 into a 1-HP split AC system originally designed for R32, focusing on the resulting compression ratio and cooling performance.
The experimental method involved varying the inlet air temperatures to the evaporator (23°C, 25°C, and 27°C) and condenser (30°C and 35°C).
Suction and discharge pressures of the compressor were measured to calculate the compression ratio.
The results showed that R32 yielded the highest compression ratio of 3.
09 and the lowest at 2.
87, while R290 produced a maximum of 2.
86 and a minimum of 2.
60.
These differences reflect the influence of each refrigerant’s thermodynamic properties on compressor operation.
R290 demonstrates potential as an environmentally friendly alternative for marine air conditioning systems, although technical adjustments are required to maintain optimal system performance.

Related Results

Analisis Kinerja R290 sebagai Pengganti R32 pada Unit AC-Split Kapasitas 9,000 Btuh/hr
Analisis Kinerja R290 sebagai Pengganti R32 pada Unit AC-Split Kapasitas 9,000 Btuh/hr
R290 is a type of natural refrigerant that has ODP = 0 and GWP = 4. While R32 from synthetic materials has ODP= 0 and GWP = 675 both are refrigerants used in Split AC. With this hi...
MODIFIKASI SISTEM PERMESINAN DAN GENERAL ARRANGEMENT KAPAL NAVIGASI BIMA SAKTI MENJADI KAPAL LATIH
MODIFIKASI SISTEM PERMESINAN DAN GENERAL ARRANGEMENT KAPAL NAVIGASI BIMA SAKTI MENJADI KAPAL LATIH
<p><em>A training ship is a ship that is used as a training ship to train cadets to become sailors. It is used in order to meet today’s sailors need. There are various ...
Tingkat Pencapaian Standar Waktu Pelayanan Pemanduan Kapal (Approach Time) di Pelabuhan Parepare
Tingkat Pencapaian Standar Waktu Pelayanan Pemanduan Kapal (Approach Time) di Pelabuhan Parepare
Kinerja pelayanan pelabuhan adalah indikator untuk menilai hasil kerja suatu pelabuhan pada periode tertentu dan menggambarkan tingkat pelayanan yang diberikan kepada pengguna jasa...
Investigasi Efisiensi Propeler Kapal Ikan Tradisional
Investigasi Efisiensi Propeler Kapal Ikan Tradisional
Kapal ikan tradisional biasanya dibuat dari kayu dan dengan pola kapal yang diperoleh secara empiris sebagai warisan turun-temurun tanpa diketahui nilai hambatan kapalnya. Adapun s...
ENERGY PERFORMANCE ANALYSIS OF R32 AND R134A REFRIGERANT FOR SPRING POOL WATER HEATER
ENERGY PERFORMANCE ANALYSIS OF R32 AND R134A REFRIGERANT FOR SPRING POOL WATER HEATER
For a country with a tropical climate, such as Indonesia, heat pump technologies are usually necessary in high-altitude regions, where the temperatures tend to be cooler, such as a...
STRATEGI PELAYANAN JASA KEAGENAN KAPAL DI PELAYARAN NASIONAL INDONESIA CABANG BATAM
STRATEGI PELAYANAN JASA KEAGENAN KAPAL DI PELAYARAN NASIONAL INDONESIA CABANG BATAM
Pelayanan jasa keagenan kapal telah berjalan dengan baik, namun masih ditemui permasalahan diantaranya ialah: kurangnya keamanan dalam pelayanan jasa keagenan, adanya keterlambatan...
Experimental Study of Performance Analysis of Split Air Conditioning Unit by Replacing Refrigerant R410A with R32 and R290
Experimental Study of Performance Analysis of Split Air Conditioning Unit by Replacing Refrigerant R410A with R32 and R290
The world phasedown of high global warming potential (GWP) refrigerants has created a need for low-GWP replacements that have equal or better performance in air conditioning system...
PEMBANGUNAN KAPAL PERIKANAN DI GALANGAN KAPAL TRADISIONAL KALIMANTAN SELATAN
PEMBANGUNAN KAPAL PERIKANAN DI GALANGAN KAPAL TRADISIONAL KALIMANTAN SELATAN
Kapal perikanan merupakan salah satu unsur dalam menentukan keberhasilan operasi penangkapan ikan.  Penelitian ini bertujuan  untuk mengetahui ; (1) tingkat teknologi; (2) jenis ka...

Back to Top