Adaptive ANN based differential protective relay for reliable power transformer protection operation during energisation

View through CrossRef
Power transformer is the most expensive equipment in electrical power system that needs continuous monitoring and fast protection response. Differential relay is usually used in power transformer protection scheme. This protection compares the difference of currents between transformer primary and secondary sides, with which a tripping signal to the circuit breaker is asserted. However, when power transformers are energized, the magnetizing inrush current is present and due to its high magnitude, the relay mal-operates. To prevent mal-operation, methods revolving around the fact that the relay should be able to discriminate between the magnetizing inrush current and the fault current must be studied. This paper presents an Artificial Neural Network(ANN) based differential relay that is designed to enable the differential relay to correct its mal-operation during energization by training the ANN and testing it with harmonic current as the restraining element. The MATLAB software is used to implement and evaluate the proposed differential relay. It is shown that the ANN based differential relay is indeed an adaptive relay when it is appropriately trained using the Network Fitting Tool. The improved differential relay models also include a reset part which enables automatic reset of the relays. Using the techniques of 2nd harmonic restraint and ANN to design a differential relay thus illustrates that the latter can successfully differentiate between magnetizing inrush and internal fault currents. With the new adaptive ANN-based differential relay, there is no mal-operation of the relay during energization. The ANN based differential relay shows better performance in terms of its ability to differentiate fault against energization current. Amazingly, the response time, when there is an internal fault, is 1 ms compared to 4.5 ms of the conventional 2nd harmonic restraint based relay.
Title: Adaptive ANN based differential protective relay for reliable power transformer protection operation during energisation
Description:
Power transformer is the most expensive equipment in electrical power system that needs continuous monitoring and fast protection response.
Differential relay is usually used in power transformer protection scheme.
This protection compares the difference of currents between transformer primary and secondary sides, with which a tripping signal to the circuit breaker is asserted.
However, when power transformers are energized, the magnetizing inrush current is present and due to its high magnitude, the relay mal-operates.
To prevent mal-operation, methods revolving around the fact that the relay should be able to discriminate between the magnetizing inrush current and the fault current must be studied.
This paper presents an Artificial Neural Network(ANN) based differential relay that is designed to enable the differential relay to correct its mal-operation during energization by training the ANN and testing it with harmonic current as the restraining element.
The MATLAB software is used to implement and evaluate the proposed differential relay.
It is shown that the ANN based differential relay is indeed an adaptive relay when it is appropriately trained using the Network Fitting Tool.
The improved differential relay models also include a reset part which enables automatic reset of the relays.
Using the techniques of 2nd harmonic restraint and ANN to design a differential relay thus illustrates that the latter can successfully differentiate between magnetizing inrush and internal fault currents.
With the new adaptive ANN-based differential relay, there is no mal-operation of the relay during energization.
The ANN based differential relay shows better performance in terms of its ability to differentiate fault against energization current.
Amazingly, the response time, when there is an internal fault, is 1 ms compared to 4.
5 ms of the conventional 2nd harmonic restraint based relay.

Related Results

Automatic Load Sharing of Transformer
Automatic Load Sharing of Transformer
Transformer plays a major role in the power system. It works 24 hours a day and provides power to the load. The transformer is excessive full, its windings are overheated which lea...
Assessment and Mitigation Studies of Voltage Sags during Sympathetic Inrush Current
Assessment and Mitigation Studies of Voltage Sags during Sympathetic Inrush Current
The system voltage may be negatively impacted by the transformer’s energisation which draws a large value of magnetising inrush current for a few seconds. During the transformer’s ...
ANALISIS PENGUJIAN RELAY PROTEKSI MENGGUNAKAN RELAY TESTING UNIT TIPE PTE-100-C PLUS
ANALISIS PENGUJIAN RELAY PROTEKSI MENGGUNAKAN RELAY TESTING UNIT TIPE PTE-100-C PLUS
Relay proteksi adalah suatu relay listrik yang digunakan untuk mengamankan peralatan-peralatan listrik terhadap kondisi abnormal. Banyaknya karakteristik beban dan penambahan beban...
High frequency modeling of power transformers under transients
High frequency modeling of power transformers under transients
This thesis presents the results related to high frequency modeling of power transformers. First, a 25kVA distribution transformer under lightning surges is tested in the laborator...
Protection Relay Setting based on Overcurrent Phenomena in Commercial Building
Protection Relay Setting based on Overcurrent Phenomena in Commercial Building
Nowadays, every single distribution system needs to install an appropriate relay to keep the system safe. The operational and commonly recommended relay for distribution systems is...
Enhancing the Sensitivity of Power Transformer Differential Protection in Power Systems.
Enhancing the Sensitivity of Power Transformer Differential Protection in Power Systems.
Differential protection is a fundamental protection scheme used to detect and isolate internal faults in power transformers. It works on the principle of comparing the currents ent...
Evaluasi Setting Over Current Relay dan Ground Fault Relay pada Penyulang Bili-Bili Satu GI Borongloe
Evaluasi Setting Over Current Relay dan Ground Fault Relay pada Penyulang Bili-Bili Satu GI Borongloe
Sebab distribusi tenaga listrik merupakan sistem tenaga listrik yang menyalurkan energi listrik ke konsumen, untuk menjaga pendistribusian tenaga listrik agar tidak terganggu maka ...
LIFE CYCLE OF TRANSFORMER 110/X KV AND ITS VALUE
LIFE CYCLE OF TRANSFORMER 110/X KV AND ITS VALUE
In a deregulated environment, power companies are in the constant process of reducing the costs of operating power facilities, with the aim of optimally improving the quality of de...