Javascript must be enabled to continue!
Power supply risk assessment method for relay protection system faults
View through CrossRef
Abstract
The influence and the potential risk due to hidden faults of a relay protection system on power supply in distribution systems are paid more and more attention to. A probability analysis method is used to analyse fault characteristics and action mechanism of dominant faults, hidden misoperation and non-operation of the relay protection systems, and failure probability model of relay protection system is constructed and simplified. The effects of dominant faults, hidden misoperation and non-operation of the relay protection systems on the reduced power supply load power are analysed, and a probabilistic model for reduced power supply load power is constructed by three parts corresponding to dominant faults, hidden misoperation and non-operation. A probability calculation method of power supply risk occurrence due to hidden faults of relay protecttion system is proposed considering the fault probability of the relay protection systems, the frequency of the hidden faults occurring in operation period, the reduced power supply load power or load power outage, and the connection mode of the in-lines, out-lines and transformers in a substation. The feasibility and applicability of the proposed method for estimation of risk value probability of the relay protection systems is verified by two studied examples.
Walter de Gruyter GmbH
Title: Power supply risk assessment method for relay protection system faults
Description:
Abstract
The influence and the potential risk due to hidden faults of a relay protection system on power supply in distribution systems are paid more and more attention to.
A probability analysis method is used to analyse fault characteristics and action mechanism of dominant faults, hidden misoperation and non-operation of the relay protection systems, and failure probability model of relay protection system is constructed and simplified.
The effects of dominant faults, hidden misoperation and non-operation of the relay protection systems on the reduced power supply load power are analysed, and a probabilistic model for reduced power supply load power is constructed by three parts corresponding to dominant faults, hidden misoperation and non-operation.
A probability calculation method of power supply risk occurrence due to hidden faults of relay protecttion system is proposed considering the fault probability of the relay protection systems, the frequency of the hidden faults occurring in operation period, the reduced power supply load power or load power outage, and the connection mode of the in-lines, out-lines and transformers in a substation.
The feasibility and applicability of the proposed method for estimation of risk value probability of the relay protection systems is verified by two studied examples.
Related Results
Adaptive ANN based differential protective relay for reliable power transformer protection operation during energisation
Adaptive ANN based differential protective relay for reliable power transformer protection operation during energisation
Power transformer is the most expensive equipment in electrical power system that needs continuous monitoring and fast protection response. Differential relay is usually used in po...
ANALISIS PENGUJIAN RELAY PROTEKSI MENGGUNAKAN RELAY TESTING UNIT TIPE PTE-100-C PLUS
ANALISIS PENGUJIAN RELAY PROTEKSI MENGGUNAKAN RELAY TESTING UNIT TIPE PTE-100-C PLUS
Relay proteksi adalah suatu relay listrik yang digunakan untuk mengamankan peralatan-peralatan listrik terhadap kondisi abnormal. Banyaknya karakteristik beban dan penambahan beban...
Subtle Faults Characterization Based on Fault Simulation and AI OBN Seismic Attributes Optimization
Subtle Faults Characterization Based on Fault Simulation and AI OBN Seismic Attributes Optimization
Abstract
Subtle faults are often below seismic resolution, especially in strike slip regimes, it is very difficult to identify them as they have small throw and the ...
Optimizing Relay Selection in D2DCommunication for Next-Generation WirelessNetworks Using Multi-Agent ReinforcementLearning: A Novel ApproachÂ
Optimizing Relay Selection in D2DCommunication for Next-Generation WirelessNetworks Using Multi-Agent ReinforcementLearning: A Novel ApproachÂ
Abstract
Device-to-device (D2D) communication offering a direct communication channel between devices has been introduced as an alternative communication technique for next...
Methodological developments for sustainability assessment of energy technologies
Methodological developments for sustainability assessment of energy technologies
During the last centuries, human activities have intensified their influence over the environment triggering environmental, social and economic problems. Among these, climate chang...
The Impact of Pre-Existing Faults on Fault Geometry during Multiphase Rifts: The Jiyang Depression, Eastern China
The Impact of Pre-Existing Faults on Fault Geometry during Multiphase Rifts: The Jiyang Depression, Eastern China
The combination of multi-phase extension and pre-existing fault reactivation results in a complex fault pattern within hydrocarbon-bearing basins, affecting hydrocarbon exploration...
Protection Relay Setting based on Overcurrent Phenomena in Commercial Building
Protection Relay Setting based on Overcurrent Phenomena in Commercial Building
Nowadays, every single distribution system needs to install an appropriate relay to keep the system safe. The operational and commonly recommended relay for distribution systems is...
POSSIBILITY OF BUILDING MICROPROCESSOR RELAY PROTECTION DEVICES ON OPEN ARCHITECTURE
POSSIBILITY OF BUILDING MICROPROCESSOR RELAY PROTECTION DEVICES ON OPEN ARCHITECTURE
"The article analyzes the structure of relay protection devices of various designs. Based on the Unified Electric Power System of the Republic of Kazakhstan prediction on the elect...