Protection Relay Setting based on Overcurrent Phenomena in Commercial Building
View through CrossRef
Nowadays, every single distribution system needs to install an appropriate relay to keep the system safe. The operational and commonly recommended relay for distribution systems is the overcurrent (OC) relay. Throughout the distribution system, the protective relay is one of the methods that can detect and protect the location according to its observation from any fault from abnormal activity. Note that time coordination between the protective equipment relay needs to be a minimum of time interruption to prevent faults occurs. The ideal setting for all coordination protection relays is necessary to protect the device against electrical failure and interference. This paper analyzes the real results data collected for the selected commercial building of an OC relay implemented in a distribution board for high voltage and low voltage downward at a commercial building. All the parameters need to be clarified first before testing has been made and measurement is carried out using the MICROTEST 860 set. Based on the analysis, it proves that according to the IEC Standard of 0.10-time multiplier Setting (TMS) is practical to be used to obtain the operation time in seconds for the current curve set. Other than that, the results show that the normal inverse curve from manual calculation results is more accurate compared to the service setting (SS) made based on the incoming setting in a real commercial building. The case study for OC relay setting is related between current injection and time-tripping, which complies with the IEC 60255-3 standard using its formula. This method was applied to determine the characteristics of the curve. Hence, this research successfully determined the proper methods for the OC relay setting for the power distribution system. Besides, the feasibility and efficiency of OC relay data transmission are tested and checked successfully to implement the measurement method in the relay coordination study.
Title: Protection Relay Setting based on Overcurrent Phenomena in Commercial Building
Description:
Nowadays, every single distribution system needs to install an appropriate relay to keep the system safe.
The operational and commonly recommended relay for distribution systems is the overcurrent (OC) relay.
Throughout the distribution system, the protective relay is one of the methods that can detect and protect the location according to its observation from any fault from abnormal activity.
Note that time coordination between the protective equipment relay needs to be a minimum of time interruption to prevent faults occurs.
The ideal setting for all coordination protection relays is necessary to protect the device against electrical failure and interference.
This paper analyzes the real results data collected for the selected commercial building of an OC relay implemented in a distribution board for high voltage and low voltage downward at a commercial building.
All the parameters need to be clarified first before testing has been made and measurement is carried out using the MICROTEST 860 set.
Based on the analysis, it proves that according to the IEC Standard of 0.
10-time multiplier Setting (TMS) is practical to be used to obtain the operation time in seconds for the current curve set.
Other than that, the results show that the normal inverse curve from manual calculation results is more accurate compared to the service setting (SS) made based on the incoming setting in a real commercial building.
The case study for OC relay setting is related between current injection and time-tripping, which complies with the IEC 60255-3 standard using its formula.
This method was applied to determine the characteristics of the curve.
Hence, this research successfully determined the proper methods for the OC relay setting for the power distribution system.
Besides, the feasibility and efficiency of OC relay data transmission are tested and checked successfully to implement the measurement method in the relay coordination study.
Related Results
Coordination of Overcurrent Relay In Distribution System
Coordination of Overcurrent Relay In Distribution System
The overcurrent phenomena are a dangerous condition that can be occurred in the electrical system and equipment. The condition of the overcurrent will cause the short-circuited cur...
Design and Construction of Inverse Time & Definite Time Overcurrent Relay Based on Arduino Uno
Design and Construction of Inverse Time & Definite Time Overcurrent Relay Based on Arduino Uno
This system is designed to detect overcurrent faults, then disconnect them from the circuit. In inverse time overcurrent relay, the relay trip time will depend on the magnitude of ...
Overcurrent Relay for Generation Distribution Utilization
Overcurrent Relay for Generation Distribution Utilization
Distributed Generation (DG) is the production of electricity from a variety of renewable energy sources that is closer to the customer and load. The addition of distributed generat...
ANALISIS PENGUJIAN RELAY PROTEKSI MENGGUNAKAN RELAY TESTING UNIT TIPE PTE-100-C PLUS
ANALISIS PENGUJIAN RELAY PROTEKSI MENGGUNAKAN RELAY TESTING UNIT TIPE PTE-100-C PLUS
Relay proteksi adalah suatu relay listrik yang digunakan untuk mengamankan peralatan-peralatan listrik terhadap kondisi abnormal. Banyaknya karakteristik beban dan penambahan beban...
Adaptive ANN based differential protective relay for reliable power transformer protection operation during energisation
Adaptive ANN based differential protective relay for reliable power transformer protection operation during energisation
Power transformer is the most expensive equipment in electrical power system that needs continuous monitoring and fast protection response. Differential relay is usually used in po...
Evaluasi Setting Over Current Relay dan Ground Fault Relay pada Penyulang Bili-Bili Satu GI Borongloe
Evaluasi Setting Over Current Relay dan Ground Fault Relay pada Penyulang Bili-Bili Satu GI Borongloe
Sebab distribusi tenaga listrik merupakan sistem tenaga listrik yang menyalurkan energi listrik ke konsumen, untuk menjaga pendistribusian tenaga listrik agar tidak terganggu maka ...
Effect of Load Variation and Fault Resistance on the Operation Time of IDMT Overcurrent Relay
Effect of Load Variation and Fault Resistance on the Operation Time of IDMT Overcurrent Relay
Fault can occur in power system due to many factors such as lightning, tree or crane encroachment, animal intervention, human error etc. Each fault occurrence has its own fault res...
Microcontroller-Based Soft Starter and Overcurrent Detector for Enhancing Performance of Induction Motor
Microcontroller-Based Soft Starter and Overcurrent Detector for Enhancing Performance of Induction Motor
When an induction motor starts up, it draws a large current, which can damage it and cause a voltage dip effect that interferes with other electrical equipment. The machine, howeve...