Coordination of Overcurrent Relay In Distribution System

View through CrossRef
The overcurrent phenomena are a dangerous condition that can be occurred in the electrical system and equipment. The condition of the overcurrent will cause the short-circuited current flows through the system and affect the other distribution line. The purpose of this study is to investigate the coordination of the overcurrent relay in different types of the distribution network which are radial distribution system, ring distribution system, and interconnected distribution system during line to ground fault occur at the bus. The generation of the overcurrent and directional overcurrent flow in the distribution network will damage the nearest equipment and reduce the power stability. The installation of the IDMT overcurrent relay in the distribution system will clear the faulty section from affecting the other distribution line. This protective device also operates to detect the abnormal condition with proper time current characteristic condition that involves the optimum time speed, accurate coordination, and sensitivity. The simulation of the IDMT overcurrent relay in the one-line diagram of the distribution network is executed by using ETAP software meanwhile the IDMT relay setting is calculated via MATLAB. 
Title: Coordination of Overcurrent Relay In Distribution System
Description:
The overcurrent phenomena are a dangerous condition that can be occurred in the electrical system and equipment.
The condition of the overcurrent will cause the short-circuited current flows through the system and affect the other distribution line.
The purpose of this study is to investigate the coordination of the overcurrent relay in different types of the distribution network which are radial distribution system, ring distribution system, and interconnected distribution system during line to ground fault occur at the bus.
The generation of the overcurrent and directional overcurrent flow in the distribution network will damage the nearest equipment and reduce the power stability.
The installation of the IDMT overcurrent relay in the distribution system will clear the faulty section from affecting the other distribution line.
This protective device also operates to detect the abnormal condition with proper time current characteristic condition that involves the optimum time speed, accurate coordination, and sensitivity.
The simulation of the IDMT overcurrent relay in the one-line diagram of the distribution network is executed by using ETAP software meanwhile the IDMT relay setting is calculated via MATLAB.
 .

Related Results

Overcurrent Relay for Generation Distribution Utilization
Overcurrent Relay for Generation Distribution Utilization
Distributed Generation (DG) is the production of electricity from a variety of renewable energy sources that is closer to the customer and load. The addition of distributed generat...
Design and Construction of Inverse Time & Definite Time Overcurrent Relay Based on Arduino Uno
Design and Construction of Inverse Time & Definite Time Overcurrent Relay Based on Arduino Uno
This system is designed to detect overcurrent faults, then disconnect them from the circuit. In inverse time overcurrent relay, the relay trip time will depend on the magnitude of ...
Protection Relay Setting based on Overcurrent Phenomena in Commercial Building
Protection Relay Setting based on Overcurrent Phenomena in Commercial Building
Nowadays, every single distribution system needs to install an appropriate relay to keep the system safe. The operational and commonly recommended relay for distribution systems is...
ANALISIS PENGUJIAN RELAY PROTEKSI MENGGUNAKAN RELAY TESTING UNIT TIPE PTE-100-C PLUS
ANALISIS PENGUJIAN RELAY PROTEKSI MENGGUNAKAN RELAY TESTING UNIT TIPE PTE-100-C PLUS
Relay proteksi adalah suatu relay listrik yang digunakan untuk mengamankan peralatan-peralatan listrik terhadap kondisi abnormal. Banyaknya karakteristik beban dan penambahan beban...
Adaptive ANN based differential protective relay for reliable power transformer protection operation during energisation
Adaptive ANN based differential protective relay for reliable power transformer protection operation during energisation
Power transformer is the most expensive equipment in electrical power system that needs continuous monitoring and fast protection response. Differential relay is usually used in po...
Effect of Load Variation and Fault Resistance on the Operation Time of IDMT Overcurrent Relay
Effect of Load Variation and Fault Resistance on the Operation Time of IDMT Overcurrent Relay
Fault can occur in power system due to many factors such as lightning, tree or crane encroachment, animal intervention, human error etc. Each fault occurrence has its own fault res...
Microcontroller-Based Soft Starter and Overcurrent Detector for Enhancing Performance of Induction Motor
Microcontroller-Based Soft Starter and Overcurrent Detector for Enhancing Performance of Induction Motor
When an induction motor starts up, it draws a large current, which can damage it and cause a voltage dip effect that interferes with other electrical equipment. The machine, howeve...