Effect of Load Variation and Fault Resistance on the Operation Time of IDMT Overcurrent Relay

View through CrossRef
Fault can occur in power system due to many factors such as lightning, tree or crane encroachment, animal intervention, human error etc. Each fault occurrence has its own fault resistance value, and this value is unknown to the protection relay used to the protect the circuit. Besides that, the connected load in power system is dynamic where the value is changing over time. It is very important for the protection relay to be as reliable as it can so that the fault can be isolated as soon as possible when a fault occur. This paper study the effect of fault resistance value and load variation on IDMT overcurrent relay operation time. This relay is used to protect the line from fault occurrence where the higher the fault current, the faster the operation time will be. MATLAB Simulink has been used to model the transmission line, source, connected load and IDMT overcurrent relay. Faults simulations were conducted for various fault resistance and load values and the effects on relay operation time have been analysed. From the results, it was found that, the higher the fault resistance, the higher the operation time while the higher the value of connected load at the end of the line, the faster the relay operation time.
Title: Effect of Load Variation and Fault Resistance on the Operation Time of IDMT Overcurrent Relay
Description:
Fault can occur in power system due to many factors such as lightning, tree or crane encroachment, animal intervention, human error etc.
Each fault occurrence has its own fault resistance value, and this value is unknown to the protection relay used to the protect the circuit.
Besides that, the connected load in power system is dynamic where the value is changing over time.
It is very important for the protection relay to be as reliable as it can so that the fault can be isolated as soon as possible when a fault occur.
This paper study the effect of fault resistance value and load variation on IDMT overcurrent relay operation time.
This relay is used to protect the line from fault occurrence where the higher the fault current, the faster the operation time will be.
MATLAB Simulink has been used to model the transmission line, source, connected load and IDMT overcurrent relay.
Faults simulations were conducted for various fault resistance and load values and the effects on relay operation time have been analysed.
From the results, it was found that, the higher the fault resistance, the higher the operation time while the higher the value of connected load at the end of the line, the faster the relay operation time.

Related Results

Coordination of Overcurrent Relay In Distribution System
Coordination of Overcurrent Relay In Distribution System
The overcurrent phenomena are a dangerous condition that can be occurred in the electrical system and equipment. The condition of the overcurrent will cause the short-circuited cur...
Integration Techniques of Fault Detection and Isolation Using Interval Observers
Integration Techniques of Fault Detection and Isolation Using Interval Observers
An interval observer has been illustrated to be a suitable approach to detect and isolate faults affecting complex dynamical industrial systems. Concerning fault detection, interv...
Design and Construction of Inverse Time & Definite Time Overcurrent Relay Based on Arduino Uno
Design and Construction of Inverse Time & Definite Time Overcurrent Relay Based on Arduino Uno
This system is designed to detect overcurrent faults, then disconnect them from the circuit. In inverse time overcurrent relay, the relay trip time will depend on the magnitude of ...
Adaptive ANN based differential protective relay for reliable power transformer protection operation during energisation
Adaptive ANN based differential protective relay for reliable power transformer protection operation during energisation
Power transformer is the most expensive equipment in electrical power system that needs continuous monitoring and fast protection response. Differential relay is usually used in po...
Overcurrent Relay for Generation Distribution Utilization
Overcurrent Relay for Generation Distribution Utilization
Distributed Generation (DG) is the production of electricity from a variety of renewable energy sources that is closer to the customer and load. The addition of distributed generat...
ANALISIS PENGUJIAN RELAY PROTEKSI MENGGUNAKAN RELAY TESTING UNIT TIPE PTE-100-C PLUS
ANALISIS PENGUJIAN RELAY PROTEKSI MENGGUNAKAN RELAY TESTING UNIT TIPE PTE-100-C PLUS
Relay proteksi adalah suatu relay listrik yang digunakan untuk mengamankan peralatan-peralatan listrik terhadap kondisi abnormal. Banyaknya karakteristik beban dan penambahan beban...
Evaluasi Setting Over Current Relay dan Ground Fault Relay pada Penyulang Bili-Bili Satu GI Borongloe
Evaluasi Setting Over Current Relay dan Ground Fault Relay pada Penyulang Bili-Bili Satu GI Borongloe
Sebab distribusi tenaga listrik merupakan sistem tenaga listrik yang menyalurkan energi listrik ke konsumen, untuk menjaga pendistribusian tenaga listrik agar tidak terganggu maka ...