ANALISA EFEKTIVITAS HEAT EXCHANGER OIL COOLER SEBELUM DAN SESUDAH MAINTENANCE

View through CrossRef
MUSI PLTA is one of the state-owned companies engaged in Hydroelectric Power Generation, MUSI PLTA is one of the largest power plants in Bengkulu Province, which is also a power plant in several provinces on the island of Sumatra. Air power plants consist of many interrelated components which then convert the potential energy of the air into mechanical energy which is then transformed into electrical energy. One of the most important components of this plant is the oil cooler. The oil cooler is a heat exchanger that functions to cool the oil that will be used as a thrust bearing on the generator. This oil cooler has a shell and tube type where two types of fluids flow separately with a two pass heat exchanger type. The effectiveness of the oil cooler unit 1 UL PLTA MUSI on conditions before and before treatment was obtained from the calculation of the effectiveness value. In the pre-maintenance condition, the effectiveness value was 9.947089947 %, while in the pre-maintenance condition the effectiveness value was 13.03 %.
Title: ANALISA EFEKTIVITAS HEAT EXCHANGER OIL COOLER SEBELUM DAN SESUDAH MAINTENANCE
Description:
MUSI PLTA is one of the state-owned companies engaged in Hydroelectric Power Generation, MUSI PLTA is one of the largest power plants in Bengkulu Province, which is also a power plant in several provinces on the island of Sumatra.
Air power plants consist of many interrelated components which then convert the potential energy of the air into mechanical energy which is then transformed into electrical energy.
One of the most important components of this plant is the oil cooler.
The oil cooler is a heat exchanger that functions to cool the oil that will be used as a thrust bearing on the generator.
This oil cooler has a shell and tube type where two types of fluids flow separately with a two pass heat exchanger type.
The effectiveness of the oil cooler unit 1 UL PLTA MUSI on conditions before and before treatment was obtained from the calculation of the effectiveness value.
In the pre-maintenance condition, the effectiveness value was 9.
947089947 %, while in the pre-maintenance condition the effectiveness value was 13.
03 %.

Related Results

ANALISIS PERBEDAAN RETURN SAHAM SEBELUM & SESUDAH HARI RAYA IDUL FITRI DAN IDUL ADHA
ANALISIS PERBEDAAN RETURN SAHAM SEBELUM & SESUDAH HARI RAYA IDUL FITRI DAN IDUL ADHA
Penelitian ini bertujuan untuk menganalisis perbedaan return saham sebelum dan sesudah hari raya idul fitri serta idul adha pada Indeks Saham Syariah Indonesia (ISSI) pada periode ...
Parametric Modeling and Economic Analysis of a 2MWth 3-Stream sCO2 Heat Exchanger
Parametric Modeling and Economic Analysis of a 2MWth 3-Stream sCO2 Heat Exchanger
Abstract This paper presents the design and cost optimization of a novel 2MWth 3-stream sCO2 plate-fin heat exchanger. This heat exchanger design is unique in that i...
Kaji efisiensi temperatur penukar panas dengan variasi aliran untuk aplikasi pengering
Kaji efisiensi temperatur penukar panas dengan variasi aliran untuk aplikasi pengering
Abstrak Heat exchanger atau alat penukar panas adalah alat-alat yang digunakan untuk mengubah temperatur fluida atau mengubah fasa fluida dengan cara mempertukarkan panasnya dengan...
ANALISIS PERFORMA HEAT EXCHANGER OIL COOLER UPPER TIPE M10-BFG PADA UNIT 1,2,3,4 PLTA SINGKARAK UNTUK TINDAKAN PEMELIHARAAN
ANALISIS PERFORMA HEAT EXCHANGER OIL COOLER UPPER TIPE M10-BFG PADA UNIT 1,2,3,4 PLTA SINGKARAK UNTUK TINDAKAN PEMELIHARAAN
ABSTRACT   Heat Exchanger is equipment used to carry out the process of exchanging heat between two fluids, either liquid (hot or cold) or gas, where these fluids have ...
Pengaruh Penggantian Heat Exchanger terhadap Suhu di dalam Kabin Pesawat Terbang Tipe Boeing B737-800/900ER
Pengaruh Penggantian Heat Exchanger terhadap Suhu di dalam Kabin Pesawat Terbang Tipe Boeing B737-800/900ER
Pesawat Boeing B737-800/900ER dilengkapi dengan sistem pendingin udara atau Airconditioning System yang merupakan bagian dari Environmental Control System (ECS). Air conditioning s...
Intelligent Monitoring and Diagnosis of CCWS Heat Exchanger For Nuclear Power Plant
Intelligent Monitoring and Diagnosis of CCWS Heat Exchanger For Nuclear Power Plant
Abstract Component Cooling Water System (CCWS) heat exchanger in nuclear power plant plays an important role in normal operation and accident condition. Because of t...
Analisis Kinerja Exhaust Gas Heat Exchanger Dengan Menggunakan Diagram Pareto
Analisis Kinerja Exhaust Gas Heat Exchanger Dengan Menggunakan Diagram Pareto
Heat Exchanger sebagai alat penukar kalor yang berfungsi untuk mengubah temperatur dan fasa suatu jenis fluida. Dalam penerapan heat exchanger terdapat permasalahan yang masih munc...
Engine Mounted Oil Cooler 3D CFD CHT Analysis for Predicting Thermal Performance
Engine Mounted Oil Cooler 3D CFD CHT Analysis for Predicting Thermal Performance
<div class="section abstract"><div class="htmlview paragraph">This paper describes steady state, computationally rigorous, three-dimensional conjugate heat transfer 3D ...