Intelligent Monitoring and Diagnosis of CCWS Heat Exchanger For Nuclear Power Plant
View through CrossRef
Abstract
Component Cooling Water System (CCWS) heat exchanger in nuclear power plant plays an important role in normal operation and accident condition. Because of the different requirements of heat conduction performance under normal operation and accident conditions, it is necessary to monitor the heat conduction performance under normal conditions to valuation the performance under accident condition. At present, the heat transfer coefficient is calculated by collecting the temperature and flow parameters of the cold and hot sides of CCWS heat exchanger. This way of valuation does not consider the influence of the change of plant operating conditions on the heat transfer coefficient of the heat exchanger, and it is also impossible to predict the failure time.The intelligent monitoring and diagnosis system using big data intelligent algorithm and failure mechanism model can automatically calculate the evaluation parameters that can characterize the trend changes of thermal and hydraulic performance of heat exchanger in real time, and realize the purpose of predicting the faults of heat exchanger in advance, thus guiding on-site maintenance personnel to accurately arrange maintenance activities.Based on the research of intelligent monitoring and diagnosis system of CCWS heat exchanger, this paper introduces the development direction and suggested realization method of CCWS heat exchanger in the intelligent process of nuclear power plant, and puts forward the conception of developing intelligent monitoring and diagnosis system of CCWS heat exchanger.
American Society of Mechanical Engineers
Title: Intelligent Monitoring and Diagnosis of CCWS Heat Exchanger For Nuclear Power Plant
Description:
Abstract
Component Cooling Water System (CCWS) heat exchanger in nuclear power plant plays an important role in normal operation and accident condition.
Because of the different requirements of heat conduction performance under normal operation and accident conditions, it is necessary to monitor the heat conduction performance under normal conditions to valuation the performance under accident condition.
At present, the heat transfer coefficient is calculated by collecting the temperature and flow parameters of the cold and hot sides of CCWS heat exchanger.
This way of valuation does not consider the influence of the change of plant operating conditions on the heat transfer coefficient of the heat exchanger, and it is also impossible to predict the failure time.
The intelligent monitoring and diagnosis system using big data intelligent algorithm and failure mechanism model can automatically calculate the evaluation parameters that can characterize the trend changes of thermal and hydraulic performance of heat exchanger in real time, and realize the purpose of predicting the faults of heat exchanger in advance, thus guiding on-site maintenance personnel to accurately arrange maintenance activities.
Based on the research of intelligent monitoring and diagnosis system of CCWS heat exchanger, this paper introduces the development direction and suggested realization method of CCWS heat exchanger in the intelligent process of nuclear power plant, and puts forward the conception of developing intelligent monitoring and diagnosis system of CCWS heat exchanger.
Related Results
Plate heat exchanger – inertia flywheel performance in loss of flow transient
Plate heat exchanger – inertia flywheel performance in loss of flow transient
Abstract
One of the most versatile types of heat exchangers used is the plate heat exchanger. It has principal advantages over other heat exchangers in that plates c...
Heat Exchanger Design and Optimization
Heat Exchanger Design and Optimization
Heat exchangers are devices that transfer heat energy between fluids by utilizing heat transfer modes of conduction and convection. The shell and tube heat exchanger configuration ...
Parametric Modeling and Economic Analysis of a 2MWth 3-Stream sCO2 Heat Exchanger
Parametric Modeling and Economic Analysis of a 2MWth 3-Stream sCO2 Heat Exchanger
Abstract
This paper presents the design and cost optimization of a novel 2MWth 3-stream sCO2 plate-fin heat exchanger. This heat exchanger design is unique in that i...
Kaji efisiensi temperatur penukar panas dengan variasi aliran untuk aplikasi pengering
Kaji efisiensi temperatur penukar panas dengan variasi aliran untuk aplikasi pengering
Abstrak Heat exchanger atau alat penukar panas adalah alat-alat yang digunakan untuk mengubah temperatur fluida atau mengubah fasa fluida dengan cara mempertukarkan panasnya dengan...
Analisis Kinerja Exhaust Gas Heat Exchanger Dengan Menggunakan Diagram Pareto
Analisis Kinerja Exhaust Gas Heat Exchanger Dengan Menggunakan Diagram Pareto
Heat Exchanger sebagai alat penukar kalor yang berfungsi untuk mengubah temperatur dan fasa suatu jenis fluida. Dalam penerapan heat exchanger terdapat permasalahan yang masih munc...
STUDY KELAYAKAN HEAT EXCHANGER 03 KILANG PPSDM MIGAS
STUDY KELAYAKAN HEAT EXCHANGER 03 KILANG PPSDM MIGAS
Pusat Pengembangan Sumber Daya Manusia Minyak dan Gas Bumi terdapat kilang minyak kapasitas pengolahan 320 m3 per hari, hasil produk pengolahan kilang ini yaitu pertasol CA, pertas...
Numerical Investigation of Power Generation Enhancement for Exhaust Heat Exchanger with Cylindrical Grooves in Thermoelectric Generator Systems
Numerical Investigation of Power Generation Enhancement for Exhaust Heat Exchanger with Cylindrical Grooves in Thermoelectric Generator Systems
<div class="section abstract"><div class="htmlview paragraph">For vehicle thermoelectric generator, heat would be directly transferred into electricity by thermoelectri...
Scaling Analysis of Passive Heat Exchanger Under Station Blackout Accident
Scaling Analysis of Passive Heat Exchanger Under Station Blackout Accident