A Comparative Study of Blood Glucose Level Measurement Between Glucometer and Semi Autoanalyser

View through CrossRef
Background; Glucometers are the excellent tools for self-monitoring of blood glucose (SMBG). Glucometer is widely used at hospitals and homes as a first line tool to get an idea about the current blood glucose levels. They are important especially in the circumstances where continuous monitoring is mandatory and at decision making levels. Materials and Methods; The Study was Conducted in Department of Biochemistry, Civil Hospital Tarn Taran. Proper informed consent was taken from all the participation, a total of 60 sample were taken. Result; We found that that at very high glucose readings (i.e. in group 3 patients having plasma glucose levels ≥ 251 mg/dl), glucometer overestimates glucose results. So, these values do not accurately reflect actual plasma glucose levels. Conclusion; Blood glucose testing with glucometer is a simple, rapid & cost effective method for glucose monitoring. On the other hand centralized laboratory glucose testing despite higher operational time and cost burden is still more reliable method for diagnosis and management of the patient. Finding in our study suggest that very high glucose values with glucometer do not accurately reflect actual plasma glucose levels; but it overestimates glucose results. So, the routine practice of performing only single testing with glucometers can lead to misdiagnosis. So, readings obtained using glucometers especially at the critical hyperglycemic levels, should be cautiously interpreted and verified with centralized laboratory. Medical professionals should depict diabetic patients the importance of periodic centralized laboratory glucose testing. A further detailed study for comparison of plasma glucose levels using glucometer and GOD-POD method in hypoglycemic patients with a larger sample size is needed.
Title: A Comparative Study of Blood Glucose Level Measurement Between Glucometer and Semi Autoanalyser
Description:
Background; Glucometers are the excellent tools for self-monitoring of blood glucose (SMBG).
Glucometer is widely used at hospitals and homes as a first line tool to get an idea about the current blood glucose levels.
They are important especially in the circumstances where continuous monitoring is mandatory and at decision making levels.
Materials and Methods; The Study was Conducted in Department of Biochemistry, Civil Hospital Tarn Taran.
Proper informed consent was taken from all the participation, a total of 60 sample were taken.
Result; We found that that at very high glucose readings (i.
e.
in group 3 patients having plasma glucose levels ≥ 251 mg/dl), glucometer overestimates glucose results.
So, these values do not accurately reflect actual plasma glucose levels.
Conclusion; Blood glucose testing with glucometer is a simple, rapid & cost effective method for glucose monitoring.
On the other hand centralized laboratory glucose testing despite higher operational time and cost burden is still more reliable method for diagnosis and management of the patient.
Finding in our study suggest that very high glucose values with glucometer do not accurately reflect actual plasma glucose levels; but it overestimates glucose results.
So, the routine practice of performing only single testing with glucometers can lead to misdiagnosis.
So, readings obtained using glucometers especially at the critical hyperglycemic levels, should be cautiously interpreted and verified with centralized laboratory.
Medical professionals should depict diabetic patients the importance of periodic centralized laboratory glucose testing.
A further detailed study for comparison of plasma glucose levels using glucometer and GOD-POD method in hypoglycemic patients with a larger sample size is needed.

Related Results

Comparison of CSF Glucose Values Obtained by Glucometer and Autoanalyzer
Comparison of CSF Glucose Values Obtained by Glucometer and Autoanalyzer
Bacterial meningitis is a disease with a high fatality rate and the chance of developing severe complications are more, which include hearing loss, seizures, limb weakness, and dif...
[RETRACTED] Guardian Blood Balance –Feel the difference Guardian Blood Balance makes! v1
[RETRACTED] Guardian Blood Balance –Feel the difference Guardian Blood Balance makes! v1
[RETRACTED]Guardian Blood Balance Reviews (Works Or Hoax) Does Guardian Botanicals Blood Balance AU Really Works? Read Updated Report! Diabetes and Hypertension is such a health p...
Primerjalna književnost na prelomu tisočletja
Primerjalna književnost na prelomu tisočletja
In a comprehensive and at times critical manner, this volume seeks to shed light on the development of events in Western (i.e., European and North American) comparative literature ...
Rapid detection of bacterial meningitis using a point-of-care glucometer
Rapid detection of bacterial meningitis using a point-of-care glucometer
Background In case of acute bacterial meningitis, a decision on the need for intensive care admission should be made within the first hour. The aim of this study was to...
Blood Glucose Measurement in Rabbits - Performance Evaluation of Portable Glucometers
Blood Glucose Measurement in Rabbits - Performance Evaluation of Portable Glucometers
Background: Blood glucose level measurement plays an important role in the diagnosis and prognosis of different clinical conditions in rabbits. Portable glucometers offer a quick a...
Evaluation of the colorimetric cyanmethemoglobin method and the automatical analyser for hemoglobin estimation
Evaluation of the colorimetric cyanmethemoglobin method and the automatical analyser for hemoglobin estimation
ABSTRACT   Hemoglobin estimation by cyanmethemoglobin method was carried out in the present study. The intensity of the color was measured by colorimeter and autoanalyser. The ...
Glucose intolerance is associated with resting heart rate among individuals without diabetes
Glucose intolerance is associated with resting heart rate among individuals without diabetes
Elevated resting heart rate is associated with cardiovascular diseases and all-cause mortality. Unmanaged diabetes is associated with high blood pressure and high resting heart rat...

Back to Top