Javascript must be enabled to continue!
A phantom for 2D dose measurements in the vicinity of metal implants for photon and proton beams
View through CrossRef
This work aimed to characterize a dedicated phantom for assessing the dose near metal implants for radiotherapy with photons and protons. A dosimetry audit phantom was redesigned to position a Gafchromic EBT-3 film within a bisected titanium pedicle screw (6.5 mm diameter). The mass density and the water equivalent thickness (WET) of the phantom material were determined. The phantom was irradiated using a photon arc and a horizontal proton beam in combination with a couch rotation of 20°, with three repeated measurements each. Treatment plans utilizing a single field covering the screw and the EBT-3 film were optimized to deliver a physical dose of 2 Gy using a collapsed cone and Monte Carlo dose engine for photons and protons, respectively. The mass density and the WET of the phantom were determined as (1.033 ± 0.010) gcm−3 and (1.022 ± 0.013), respectively. Ionisation chamber measurements agreed within 1% (photons) and 0.5% (protons) with the calculated dose values. Relative photon dosimetry measurements using EBT-3 films revealed an agreement between measured and calculated horizontal profiles within the confidence interval for areas beyond 5 mm from the center. For photon plans, significant deviations of more than 10% were found at the interfaces between phantom material and screw. The proton measurements showed a gradual decrease of 3% across both profiles. In contrast to photon plans, no dose increase was measured within the screw, but significant dose fluctuations (>5%) in the beam’s exit region. This study showed that the behavior of dose engine is affected by metal implants and thus dosimetric measurements are highly recommended. The presented phantom can serve as foundation for dedicated end-2-end phantoms.
Frontiers Media SA
Title: A phantom for 2D dose measurements in the vicinity of metal implants for photon and proton beams
Description:
This work aimed to characterize a dedicated phantom for assessing the dose near metal implants for radiotherapy with photons and protons.
A dosimetry audit phantom was redesigned to position a Gafchromic EBT-3 film within a bisected titanium pedicle screw (6.
5 mm diameter).
The mass density and the water equivalent thickness (WET) of the phantom material were determined.
The phantom was irradiated using a photon arc and a horizontal proton beam in combination with a couch rotation of 20°, with three repeated measurements each.
Treatment plans utilizing a single field covering the screw and the EBT-3 film were optimized to deliver a physical dose of 2 Gy using a collapsed cone and Monte Carlo dose engine for photons and protons, respectively.
The mass density and the WET of the phantom were determined as (1.
033 ± 0.
010) gcm−3 and (1.
022 ± 0.
013), respectively.
Ionisation chamber measurements agreed within 1% (photons) and 0.
5% (protons) with the calculated dose values.
Relative photon dosimetry measurements using EBT-3 films revealed an agreement between measured and calculated horizontal profiles within the confidence interval for areas beyond 5 mm from the center.
For photon plans, significant deviations of more than 10% were found at the interfaces between phantom material and screw.
The proton measurements showed a gradual decrease of 3% across both profiles.
In contrast to photon plans, no dose increase was measured within the screw, but significant dose fluctuations (>5%) in the beam’s exit region.
This study showed that the behavior of dose engine is affected by metal implants and thus dosimetric measurements are highly recommended.
The presented phantom can serve as foundation for dedicated end-2-end phantoms.
Related Results
Body image and perception among adults with and without phantom limb pain
Body image and perception among adults with and without phantom limb pain
AbstractBackgroundFollowing lower‐limb amputation, phantom limb pain (i.e., pain perceived as coming from the amputated portion of the limb) is common. Phantom limb pain may be ass...
Simulation of proton and photon depth dose distributions using FLUKA and PHIT
Simulation of proton and photon depth dose distributions using FLUKA and PHIT
The most popular radiation therapy currently used for cancer treatment is photon radiation. Nevertheless, there is damage to normal tissue resulting from photon energy deposition. ...
Accelerating and improving radiochromic film calibration by utilizing the dose ratio in photon and proton beams
Accelerating and improving radiochromic film calibration by utilizing the dose ratio in photon and proton beams
AbstractPurposeRadiochromic films are versatile 2D dosimeters with high‐resolution and near tissue equivalence. To assure high precision and accuracy, a time‐consuming calibration ...
SU‐FF‐T‐448: Validation of a New Photon Dose Calculation Model—Analytical Anisotropic Algorithm
SU‐FF‐T‐448: Validation of a New Photon Dose Calculation Model—Analytical Anisotropic Algorithm
Purpose: To validate a new photon dose calculation model Analytical Anisotropic Algorithm (AAA) on Eclipse™ treatment planning system (TPS). Comparison of AAA dose calculation was ...
Characterization of EBT3 radiochromic films for dosimetry of proton beams in the presence of magnetic fields
Characterization of EBT3 radiochromic films for dosimetry of proton beams in the presence of magnetic fields
PurposeRadiochromic film dosimetry is extensively used for quality assurance in photon and proton beam therapy. So far, GafchromicTM EBT3 film appears as a strong candidate to be u...
Odd version Mathieu-Gaussian beam based on Green function
Odd version Mathieu-Gaussian beam based on Green function
Like the theoretical pattern of non-diffracting Bessel beams, ideal non-diffracting Mathieu beams also carry infinite energy, but cannot be generated as a physically realizable ent...
Characteristic of EBT-XD and EBT3 radiochromic film dosimetry for photon and proton beams
Characteristic of EBT-XD and EBT3 radiochromic film dosimetry for photon and proton beams
Abstract
Recently, a new type of radiochromic film, the EBT-XD film, has been introduced for high dose radiotherapy. The EBT-XD film contains the same structure a...
Shear Stresses of Hollow Lightweight Concrete Beams Made with Wood Waste
Shear Stresses of Hollow Lightweight Concrete Beams Made with Wood Waste
Hollow Lightweight Concrete (HLC) beams are gaining popularity due to low cost and low weight as compared with the Solid Lightweight Concrete (SLC) beams. HLC and SLC beams decreas...

