SU‐FF‐I‐167: Non‐Contact Ultrasound Imaging Applied to Cortical Bone Phantoms for Determination of Bone Mineral Density, Speed of Sound, and Ultrasound Attenuation

View through CrossRef
A non‐contact ultrasound imaging (NCU) system including transmitting and receiving transducers coupled to the air was applied to custom designed cortical bone phantoms to determine bone mineral density, speed of sound, integrated acoustical response and attenuation for possible medical applications in quantitative ultrasound imaging. Air gaps of greater than a centimeter for two non‐contact transducers specially designed for thin cortical bones such as those in the distal radius, two transmission as well as two reflection paths, and a digital signal processor were used to collect data on cortical bone phantoms of nominal density that varied from 1.17 g/cm3 to 2.25 g/ cm3, with nominal bone mineral density (BMD) from 0 g/ cm3 to 1.7 g/cm3. Good correlation between nominal density and measured speed of sound, integrated acoustical response, and attenuation was obtained for all of our phantoms and techniques for limiting various sources of systematic errors were studied. In particular, reproducibility, agreement with contact ultrasound, and stability for speed of sound and other parameters versus phantom BMD was found to be at a level of a few (about 1–3) percent over a period of several months when the NCU system was carefully and routinely optimized and calibrated. The results of these investigations suggest that non‐contact ultrasound might find applications in quantitative bone assessment and in medical imaging in the near future.
Title: SU‐FF‐I‐167: Non‐Contact Ultrasound Imaging Applied to Cortical Bone Phantoms for Determination of Bone Mineral Density, Speed of Sound, and Ultrasound Attenuation
Description:
A non‐contact ultrasound imaging (NCU) system including transmitting and receiving transducers coupled to the air was applied to custom designed cortical bone phantoms to determine bone mineral density, speed of sound, integrated acoustical response and attenuation for possible medical applications in quantitative ultrasound imaging.
Air gaps of greater than a centimeter for two non‐contact transducers specially designed for thin cortical bones such as those in the distal radius, two transmission as well as two reflection paths, and a digital signal processor were used to collect data on cortical bone phantoms of nominal density that varied from 1.
17 g/cm3 to 2.
25 g/ cm3, with nominal bone mineral density (BMD) from 0 g/ cm3 to 1.
7 g/cm3.
Good correlation between nominal density and measured speed of sound, integrated acoustical response, and attenuation was obtained for all of our phantoms and techniques for limiting various sources of systematic errors were studied.
In particular, reproducibility, agreement with contact ultrasound, and stability for speed of sound and other parameters versus phantom BMD was found to be at a level of a few (about 1–3) percent over a period of several months when the NCU system was carefully and routinely optimized and calibrated.
The results of these investigations suggest that non‐contact ultrasound might find applications in quantitative bone assessment and in medical imaging in the near future.

Related Results

Frequency of Common Chromosomal Abnormalities in Patients with Idiopathic Acquired Aplastic Anemia
Frequency of Common Chromosomal Abnormalities in Patients with Idiopathic Acquired Aplastic Anemia
Objective: To determine the frequency of common chromosomal aberrations in local population idiopathic determine the frequency of common chromosomal aberrations in local population...
Noncontact ultrasound imaging applied to cortical bone phantoms
Noncontact ultrasound imaging applied to cortical bone phantoms
Purpose:The purpose of this paper was to take the first steps toward applying noncontact ultrasound (NCU) to the tasks of monitoring osteoporosis and quantitative ultrasound imagin...
SU‐D‐220‐06: Non‐Contact (Air‐Coupled) Ultrasound Applied to Cortical Bone Phantoms
SU‐D‐220‐06: Non‐Contact (Air‐Coupled) Ultrasound Applied to Cortical Bone Phantoms
Purpose: The purpose was to take the first steps towards applying Non‐Contact Ultrasound (NCU) to the in‐vivo monitoring of osteoporosis and to skeletal quantitative ultrasound ima...
SU‐FF‐I‐26: Tissue Equivalent Phantoms for the Evaluation of Tube Current Modulated CT Dose and Image Quality
SU‐FF‐I‐26: Tissue Equivalent Phantoms for the Evaluation of Tube Current Modulated CT Dose and Image Quality
Purpose: To develop and test new, flexible, tissue‐equivalent phantoms for the evaluation of tube current modulation dose reduction and image quality in CT. The developed phantom m...
Photothermal Response of Tissue Phantoms Containing Multi-Walled Carbon Nanotubes
Photothermal Response of Tissue Phantoms Containing Multi-Walled Carbon Nanotubes
Inclusion of multi-walled carbon nanotubes (MWNTs) into tissue prior to laser therapy has the potential to enhance the selectivity and effectiveness of cancer therapy by providing ...
Abnormalities in Bone Mineral Density and Bone Histology in Thalassemia
Abnormalities in Bone Mineral Density and Bone Histology in Thalassemia
Abstract This study demonstrated that there was extensive iron staining on trabecular surface and marked reduction in trabecular bone volume without significant alte...
Modeling methods for dispersive sound speed profiles of the Martian atmosphere and their effects on sound propagation paths
Modeling methods for dispersive sound speed profiles of the Martian atmosphere and their effects on sound propagation paths
At present, Mars acoustic detection is gradually becoming an important new tool for the knowledge and exploration of Mars. To explore the sources of Mars sound, it is necessary to ...

Back to Top