Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

SU‐FF‐I‐26: Tissue Equivalent Phantoms for the Evaluation of Tube Current Modulated CT Dose and Image Quality

View through CrossRef
Purpose: To develop and test new, flexible, tissue‐equivalent phantoms for the evaluation of tube current modulation dose reduction and image quality in CT. The developed phantom material also has applications for mammographic and 4‐D time varying phantoms. Method and Materials: A compressible, flexible, urethane‐based tissue equivalent phantom material was developed and utilized in the production of ellipsoid shaped phantoms for CT imaging. Multiple phantoms were created, each with different major (26–40 cm) and minor (18–28 cm) axes, in order to model patients of varying dimensions and thicknesses. All phantoms were made to be integrated with a Catphan CT image quality phantom as well as CTDI dose assessment phantoms. Image evaluation software was utilized in order to evaluate several image quality parameters in CT images taken using the phantoms in order to quantify the effects of tube current modulation in CT scanners for varying techniques. Ion chamber and gated fiber optically coupled dosimeters were also used with the phantoms in order to evaluate the effects of tube current modulation on dose to patients of varying dimensions. Results: It was found that the use of ellipsoid shaped phantoms allowed for more accurate observation of dose and image quality effects of tube current modulation in CT scanners over traditional circular acrylic phantoms. Patient doses were found the be less for studies in which tube current modulation was in use as compared to standard CT techniques, however the degree of dose reduction was found to be largely influenced by the major and minor axes of the ellipse. Conclusion: This work shows potential of ellipsoid phantoms to aid in dose reduction in CT scanning through tube current modulation by allowing more accurate modeling of actual patient dimensions.
Title: SU‐FF‐I‐26: Tissue Equivalent Phantoms for the Evaluation of Tube Current Modulated CT Dose and Image Quality
Description:
Purpose: To develop and test new, flexible, tissue‐equivalent phantoms for the evaluation of tube current modulation dose reduction and image quality in CT.
The developed phantom material also has applications for mammographic and 4‐D time varying phantoms.
Method and Materials: A compressible, flexible, urethane‐based tissue equivalent phantom material was developed and utilized in the production of ellipsoid shaped phantoms for CT imaging.
Multiple phantoms were created, each with different major (26–40 cm) and minor (18–28 cm) axes, in order to model patients of varying dimensions and thicknesses.
All phantoms were made to be integrated with a Catphan CT image quality phantom as well as CTDI dose assessment phantoms.
Image evaluation software was utilized in order to evaluate several image quality parameters in CT images taken using the phantoms in order to quantify the effects of tube current modulation in CT scanners for varying techniques.
Ion chamber and gated fiber optically coupled dosimeters were also used with the phantoms in order to evaluate the effects of tube current modulation on dose to patients of varying dimensions.
Results: It was found that the use of ellipsoid shaped phantoms allowed for more accurate observation of dose and image quality effects of tube current modulation in CT scanners over traditional circular acrylic phantoms.
Patient doses were found the be less for studies in which tube current modulation was in use as compared to standard CT techniques, however the degree of dose reduction was found to be largely influenced by the major and minor axes of the ellipse.
Conclusion: This work shows potential of ellipsoid phantoms to aid in dose reduction in CT scanning through tube current modulation by allowing more accurate modeling of actual patient dimensions.

Related Results

Blunt Chest Trauma and Chylothorax: A Systematic Review
Blunt Chest Trauma and Chylothorax: A Systematic Review
Abstract Introduction: Although traumatic chylothorax is predominantly associated with penetrating injuries, instances following blunt trauma, as a rare and challenging condition, ...
Photothermal Response of Tissue Phantoms Containing Multi-Walled Carbon Nanotubes
Photothermal Response of Tissue Phantoms Containing Multi-Walled Carbon Nanotubes
Inclusion of multi-walled carbon nanotubes (MWNTs) into tissue prior to laser therapy has the potential to enhance the selectivity and effectiveness of cancer therapy by providing ...
SUMMARY
SUMMARY
SUMMARYThe purpose of the present monograph is to give an account of the distribution of fibrinolytic components in the organism, with special reference to the tissue activator of ...
Non-Recommended Publishing Lists: Strategies for Detecting Deceitful Journals
Non-Recommended Publishing Lists: Strategies for Detecting Deceitful Journals
Abstract The rapid growth of open access publishing (OAP) has significantly improved the accessibility and dissemination of scientific knowledge. However, this expansion has also c...
Tube Shunt Related Complications in Pediatrics
Tube Shunt Related Complications in Pediatrics
Although medical therapy is usually an excellent therapeutic option in the adult population, in children it is often ineffective or associated with an undesirable risk:benefit rati...
Accelerating and improving radiochromic film calibration by utilizing the dose ratio in photon and proton beams
Accelerating and improving radiochromic film calibration by utilizing the dose ratio in photon and proton beams
AbstractPurposeRadiochromic films are versatile 2D dosimeters with high‐resolution and near tissue equivalence. To assure high precision and accuracy, a time‐consuming calibration ...

Back to Top