Noncontact ultrasound imaging applied to cortical bone phantoms

View through CrossRef
Purpose:The purpose of this paper was to take the first steps toward applying noncontact ultrasound (NCU) to the tasks of monitoring osteoporosis and quantitative ultrasound imaging (QUS) of cortical bone. The authors also focused on the advantages of NCU, such as its lack of reliance on a technologist to apply transducers and a layer of acoustical coupling gel, the ability of the transducers to operate autonomously as specified by preprogrammed software, and the likely reduction in statistical and systematic errors associated with the variability in the pressure applied by the clinician to the transmitting transducer that NCU might provide. The authors also undertook this study in order to find additional applications of NCU beyond its past limited usage in assessing the severity of third degree burns.Methods:A noncontact ultrasound imaging system using a pair of specially designed broadband, 1.5 MHz noncontact piezoelectric transducers and cortical bone phantoms, were used to determine bone mineral density (BMD), speed of sound (SOS), integrated response (IR), and ultrasonic transmittance. Air gaps of greater than 3 cm, two transmission and two reflection paths, and a digital signal processor were also used in the collection of data from phantoms of nominal mass densities that varied from 1.17 to 2.25 g/cm3 and in bone mineral density from 0 to 1.7 g/cm3.Results:Good correlations between known BMD and measured SOS, IR, and transmittance were obtained for all 17 phantoms, and methods for quantifying and minimizing sources of systematic errors were outlined. The BMD of the phantom sets extended through most of thein vivo range found in cortical bone. A total of 16–20 repeated measurements of the SOS, thickness, and IR for the phantom set that were conducted over a period of several months showed a small variation in the range of measurements of ±1%–2%. These NCU data were shown to be in agreement with similar results using contact ultrasound to be within 1%–2%. Transmittance images of cortical bone phantoms showed differences in the nominal overall BMD values of the phantoms that were large enough to be distinguished by a visual examination. A list of possible sources of errors in quantitative NCU was also included in this study.Conclusions:The results of this paper suggest that NCU might find additional applications in medical imaging, beyond its original and only previous usage in assessing third degree burns. The fact that the authors' phantom measurements using conventional, gel coupled ultrasound are in agreement with those obtained with NCU demonstrates that in spite of large additional levels of attenuation of up to 150 dB and new error sources, NCU could have comparable levels of accuracy to those of conventional quantitative ultrasound, while providing the medical and patient comfort‐related advantages of not involving direct contact.
Title: Noncontact ultrasound imaging applied to cortical bone phantoms
Description:
Purpose:The purpose of this paper was to take the first steps toward applying noncontact ultrasound (NCU) to the tasks of monitoring osteoporosis and quantitative ultrasound imaging (QUS) of cortical bone.
The authors also focused on the advantages of NCU, such as its lack of reliance on a technologist to apply transducers and a layer of acoustical coupling gel, the ability of the transducers to operate autonomously as specified by preprogrammed software, and the likely reduction in statistical and systematic errors associated with the variability in the pressure applied by the clinician to the transmitting transducer that NCU might provide.
The authors also undertook this study in order to find additional applications of NCU beyond its past limited usage in assessing the severity of third degree burns.
Methods:A noncontact ultrasound imaging system using a pair of specially designed broadband, 1.
5 MHz noncontact piezoelectric transducers and cortical bone phantoms, were used to determine bone mineral density (BMD), speed of sound (SOS), integrated response (IR), and ultrasonic transmittance.
Air gaps of greater than 3 cm, two transmission and two reflection paths, and a digital signal processor were also used in the collection of data from phantoms of nominal mass densities that varied from 1.
17 to 2.
25 g/cm3 and in bone mineral density from 0 to 1.
7 g/cm3.
Results:Good correlations between known BMD and measured SOS, IR, and transmittance were obtained for all 17 phantoms, and methods for quantifying and minimizing sources of systematic errors were outlined.
The BMD of the phantom sets extended through most of thein vivo range found in cortical bone.
A total of 16–20 repeated measurements of the SOS, thickness, and IR for the phantom set that were conducted over a period of several months showed a small variation in the range of measurements of ±1%–2%.
These NCU data were shown to be in agreement with similar results using contact ultrasound to be within 1%–2%.
Transmittance images of cortical bone phantoms showed differences in the nominal overall BMD values of the phantoms that were large enough to be distinguished by a visual examination.
A list of possible sources of errors in quantitative NCU was also included in this study.
Conclusions:The results of this paper suggest that NCU might find additional applications in medical imaging, beyond its original and only previous usage in assessing third degree burns.
The fact that the authors' phantom measurements using conventional, gel coupled ultrasound are in agreement with those obtained with NCU demonstrates that in spite of large additional levels of attenuation of up to 150 dB and new error sources, NCU could have comparable levels of accuracy to those of conventional quantitative ultrasound, while providing the medical and patient comfort‐related advantages of not involving direct contact.

Related Results

Frequency of Common Chromosomal Abnormalities in Patients with Idiopathic Acquired Aplastic Anemia
Frequency of Common Chromosomal Abnormalities in Patients with Idiopathic Acquired Aplastic Anemia
Objective: To determine the frequency of common chromosomal aberrations in local population idiopathic determine the frequency of common chromosomal aberrations in local population...
Poster 107: The Use of Coacervate Sustained Release System to Identify the Most Potent BMP for Bone Regeneration
Poster 107: The Use of Coacervate Sustained Release System to Identify the Most Potent BMP for Bone Regeneration
Objectives: Bone morphogenetic proteins (BMPs) belong to the transforming growth factor superfamily that were first discovered by Marshall Urist. There are 14 B...
SU‐FF‐I‐26: Tissue Equivalent Phantoms for the Evaluation of Tube Current Modulated CT Dose and Image Quality
SU‐FF‐I‐26: Tissue Equivalent Phantoms for the Evaluation of Tube Current Modulated CT Dose and Image Quality
Purpose: To develop and test new, flexible, tissue‐equivalent phantoms for the evaluation of tube current modulation dose reduction and image quality in CT. The developed phantom m...
Photothermal Response of Tissue Phantoms Containing Multi-Walled Carbon Nanotubes
Photothermal Response of Tissue Phantoms Containing Multi-Walled Carbon Nanotubes
Inclusion of multi-walled carbon nanotubes (MWNTs) into tissue prior to laser therapy has the potential to enhance the selectivity and effectiveness of cancer therapy by providing ...
SU‐D‐220‐06: Non‐Contact (Air‐Coupled) Ultrasound Applied to Cortical Bone Phantoms
SU‐D‐220‐06: Non‐Contact (Air‐Coupled) Ultrasound Applied to Cortical Bone Phantoms
Purpose: The purpose was to take the first steps towards applying Non‐Contact Ultrasound (NCU) to the in‐vivo monitoring of osteoporosis and to skeletal quantitative ultrasound ima...
The sonographic identification of cortical bone interruptions in rheumatoid arthritis: a morphological approach
The sonographic identification of cortical bone interruptions in rheumatoid arthritis: a morphological approach
Bone erosions are the hallmark of structural damage in rheumatoid arthritis (RA). Among imaging techniques, ultrasonography (US) has emerged as an accurate, reliable, repeatable, l...

Back to Top