Physical and biological impacts of collimator‐scattered protons in spot‐scanning proton therapy

View through CrossRef
AbstractTo improve the penumbra of low‐energy beams used in spot‐scanning proton therapy, various collimation systems have been proposed and used in clinics. In this paper, focused on patient‐specific brass collimators, the collimator‐scattered protons' physical and biological effects were investigated. The Geant4 Monte Carlo code was used to model the collimators mounted on the scanning nozzle of the Hokkaido University Hospital. A systematic survey was performed in water phantom with various‐sized rectangular targets; range (5–20 cm), spread‐out Bragg peak (SOBP) (5–10 cm), and field size (2 × 2–16 × 16 cm2). It revealed that both the range and SOBP dependences of the physical dose increase had similar trends to passive scattering methods, that is, it increased largely with the range and slightly with the SOBP. The physical impact was maximized at the surface (3%–22% for the tested geometries) and decreased with depth. In contrast, the field size (FS) dependence differed from that observed in passive scattering: the increase was high for both small and large FSs. This may be attributed to the different phase‐space shapes at the target boundary between the two dose delivery methods. Next, the biological impact was estimated based on the increase in dose‐averaged linear energy transfer (LETd) and relative biological effectiveness (RBE). The LETd of the collimator‐scattered protons were several keV/μm higher than that of unscattered ones; however, since this large increase was observed only at the positions receiving a small scattered dose, the overall LETd increase was negligible. As a consequence, the RBE increase did not exceed 0.05. Finally, the effects on patient geometries were estimated by testing two patient plans, and a negligible RBE increase (0.9% at most in the critical organs at surface) was observed in both cases. Therefore, the impact of collimator‐scattered protons is almost entirely attributed to the physical dose increase, while the RBE increase is negligible.
Title: Physical and biological impacts of collimator‐scattered protons in spot‐scanning proton therapy
Description:
AbstractTo improve the penumbra of low‐energy beams used in spot‐scanning proton therapy, various collimation systems have been proposed and used in clinics.
In this paper, focused on patient‐specific brass collimators, the collimator‐scattered protons' physical and biological effects were investigated.
The Geant4 Monte Carlo code was used to model the collimators mounted on the scanning nozzle of the Hokkaido University Hospital.
A systematic survey was performed in water phantom with various‐sized rectangular targets; range (5–20 cm), spread‐out Bragg peak (SOBP) (5–10 cm), and field size (2 × 2–16 × 16 cm2).
It revealed that both the range and SOBP dependences of the physical dose increase had similar trends to passive scattering methods, that is, it increased largely with the range and slightly with the SOBP.
The physical impact was maximized at the surface (3%–22% for the tested geometries) and decreased with depth.
In contrast, the field size (FS) dependence differed from that observed in passive scattering: the increase was high for both small and large FSs.
This may be attributed to the different phase‐space shapes at the target boundary between the two dose delivery methods.
Next, the biological impact was estimated based on the increase in dose‐averaged linear energy transfer (LETd) and relative biological effectiveness (RBE).
The LETd of the collimator‐scattered protons were several keV/μm higher than that of unscattered ones; however, since this large increase was observed only at the positions receiving a small scattered dose, the overall LETd increase was negligible.
As a consequence, the RBE increase did not exceed 0.
05.
Finally, the effects on patient geometries were estimated by testing two patient plans, and a negligible RBE increase (0.
9% at most in the critical organs at surface) was observed in both cases.
Therefore, the impact of collimator‐scattered protons is almost entirely attributed to the physical dose increase, while the RBE increase is negligible.

Related Results

SU‐F‐T‐131: No Increase in Biological Effectiveness Through Collimator Scattered Low Energy Protons
SU‐F‐T‐131: No Increase in Biological Effectiveness Through Collimator Scattered Low Energy Protons
Purpose:To reduce the lateral penumbra of low‐energy proton beams, brass collimators are often used in spot‐scanning proton therapy (SSPT). This study investigates the increase in ...
MO‐SAM‐BRB‐02: Proton Physics and Technology
MO‐SAM‐BRB‐02: Proton Physics and Technology
The dose localization advantages of proton beams derive primarily from the Bragg peak in the proton stopping distribution. Therefore, the potential clinical gains expected form pro...
Dynamic collimator trajectory algorithm for multiple metastases dynamic conformal arc treatment planning
Dynamic collimator trajectory algorithm for multiple metastases dynamic conformal arc treatment planning
PurposeTo develop an algorithm for dynamic collimator positioning to optimize beam's eye view (BEV) fitting of targets in dynamic conformal arc (DCA)‐based radiotherapy procedures,...
SU‐E‐T‐47: A Monte Carlo Model of a Spot Scanning Proton Beam Based On a Synchrotron Proton Therapy Accelerator
SU‐E‐T‐47: A Monte Carlo Model of a Spot Scanning Proton Beam Based On a Synchrotron Proton Therapy Accelerator
Purpose:To build the model of a spot scanning proton beam for the dose calculation of a synchrotron proton therapy accelerator, which is capable of accelerating protons from 50 up ...
Practical collimator optimization in the management of prostate IMRT planning: A feasibility study
Practical collimator optimization in the management of prostate IMRT planning: A feasibility study
AbstractThe objective of this study was to evaluate the delivery efficiency of intensity modulated radiation therapy (IMRT) with a non-zero collimator rotation approach compared to...
Evaluating the Science to Inform the Physical Activity Guidelines for Americans Midcourse Report
Evaluating the Science to Inform the Physical Activity Guidelines for Americans Midcourse Report
Abstract The Physical Activity Guidelines for Americans (Guidelines) advises older adults to be as active as possible. Yet, despite the well documented benefits of physical activi...
WE‐AB‐209‐06: Dynamic Collimator Trajectory Algorithm for Use in VMAT Treatment Deliveries
WE‐AB‐209‐06: Dynamic Collimator Trajectory Algorithm for Use in VMAT Treatment Deliveries
Purpose:To develop advanced dynamic collimator positioning algorithms for optimal beam's‐eye‐view (BEV) fitting of targets in VMAT procedures, including multiple metastases stereot...
Computer simulation of an excess proton in aqueous systems
Computer simulation of an excess proton in aqueous systems
This thesis aims at studying the microscopic physical-chemical properties of an excess proton in aqueous systems. From bulk water environments to narrow hydrophobic channels constr...