WE‐AB‐209‐06: Dynamic Collimator Trajectory Algorithm for Use in VMAT Treatment Deliveries
View through CrossRef
Purpose:To develop advanced dynamic collimator positioning algorithms for optimal beam's‐eye‐view (BEV) fitting of targets in VMAT procedures, including multiple metastases stereotactic radiosurgery procedures.Methods:A trajectory algorithm was developed, which can dynamically modify the angle of the collimator as a function of VMAT control point to provide optimized collimation of target volume(s). Central to this algorithm is a concept denoted “whitespace”, defined as area within the jaw‐defined BEV field, outside of the PTV, and not shielded by the MLC when fit to the PTV. Calculating whitespace at all collimator angles and every control point, a two‐dimensional topographical map depicting the tightness‐of‐fit of the MLC was generated. A variety of novel searching algorithms identified a number of candidate trajectories of continuous collimator motion. Ranking these candidate trajectories according to their accrued whitespace value produced an optimal solution for navigation of this map.Results:All trajectories were normalized to minimum possible (i.e. calculated without consideration of collimator motion constraints) accrued whitespace. On an acoustic neuroma case, a random walk algorithm generated a trajectory with 151% whitespace; random walk including a mandatory anchor point improved this to 148%; gradient search produced a trajectory with 137%; and bi‐directional gradient search generated a trajectory with 130% whitespace. For comparison, a fixed collimator angle of 30° and 330° accumulated 272% and 228% of whitespace, respectively. The algorithm was tested on a clinical case with two metastases (single isocentre) and identified collimator angles that allow for simultaneous irradiation of the PTVs while minimizing normal tissue irradiation.Conclusion:Dynamic collimator trajectories have the potential to improve VMAT deliveries through increased efficiency and reduced normal tissue dose, especially in treatment of multiple cranial metastases, without significant safety concerns that hinder immediate clinical implementation.
Title: WE‐AB‐209‐06: Dynamic Collimator Trajectory Algorithm for Use in VMAT Treatment Deliveries
Description:
Purpose:To develop advanced dynamic collimator positioning algorithms for optimal beam's‐eye‐view (BEV) fitting of targets in VMAT procedures, including multiple metastases stereotactic radiosurgery procedures.
Methods:A trajectory algorithm was developed, which can dynamically modify the angle of the collimator as a function of VMAT control point to provide optimized collimation of target volume(s).
Central to this algorithm is a concept denoted “whitespace”, defined as area within the jaw‐defined BEV field, outside of the PTV, and not shielded by the MLC when fit to the PTV.
Calculating whitespace at all collimator angles and every control point, a two‐dimensional topographical map depicting the tightness‐of‐fit of the MLC was generated.
A variety of novel searching algorithms identified a number of candidate trajectories of continuous collimator motion.
Ranking these candidate trajectories according to their accrued whitespace value produced an optimal solution for navigation of this map.
Results:All trajectories were normalized to minimum possible (i.
e.
calculated without consideration of collimator motion constraints) accrued whitespace.
On an acoustic neuroma case, a random walk algorithm generated a trajectory with 151% whitespace; random walk including a mandatory anchor point improved this to 148%; gradient search produced a trajectory with 137%; and bi‐directional gradient search generated a trajectory with 130% whitespace.
For comparison, a fixed collimator angle of 30° and 330° accumulated 272% and 228% of whitespace, respectively.
The algorithm was tested on a clinical case with two metastases (single isocentre) and identified collimator angles that allow for simultaneous irradiation of the PTVs while minimizing normal tissue irradiation.
Conclusion:Dynamic collimator trajectories have the potential to improve VMAT deliveries through increased efficiency and reduced normal tissue dose, especially in treatment of multiple cranial metastases, without significant safety concerns that hinder immediate clinical implementation.
Related Results
Modified VMAT Plans for Locally Advanced Centrally Located Non-Small Cell Lung Cancer (NSCLC)
Modified VMAT Plans for Locally Advanced Centrally Located Non-Small Cell Lung Cancer (NSCLC)
Objectives: This study aimed to find the optimal radiotherapy VMAT plans, that achieved high conformity and homogeneity to the planned target volume (PTV), and minimize the dose to...
Dynamic collimator trajectory algorithm for multiple metastases dynamic conformal arc treatment planning
Dynamic collimator trajectory algorithm for multiple metastases dynamic conformal arc treatment planning
PurposeTo develop an algorithm for dynamic collimator positioning to optimize beam's eye view (BEV) fitting of targets in dynamic conformal arc (DCA)‐based radiotherapy procedures,...
Strategies for reducing ovarian dose in volumetric modulated arc therapy (VMAT) for postoperative uterine cervical cancer
Strategies for reducing ovarian dose in volumetric modulated arc therapy (VMAT) for postoperative uterine cervical cancer
Objective:
To reduce the ovarian dose with volumetric modulated arc therapy (VMAT), an original VMAT was designed with two types of arcs to restrict angles and fi...
COMPARISON OF COPLANAR AND NON- COPLANARVMAT FOR BRAIN CANCER BY USING THE DOSIMETRICAL AND RADIOBIOLOGICAL INDICES
COMPARISON OF COPLANAR AND NON- COPLANARVMAT FOR BRAIN CANCER BY USING THE DOSIMETRICAL AND RADIOBIOLOGICAL INDICES
Background: Recent techniques of radiotherapy such as volumetric modulated arc therapy (VMAT) that delivered in Coplanar technique or non-coplanar technique allows to deliver high ...
Feasibility of 4D VMAT-CT
Feasibility of 4D VMAT-CT
Abstract
Objective. Feasibility of three-dimensional (3D) tracking of volumetric modulated arc therapy (VMAT) based on VMAT–computed tomography (V...
Dosimetric comparative study of Volumetric Modulated Arc Therapy (VMAT), Intensity Modulated Radiotherapy (IMRT), and ThreeDimensional Conformal Radiation therapy (3DCRT) for post-mastectomy radiotherapy (PMRT) in Left breast cancer patients
Dosimetric comparative study of Volumetric Modulated Arc Therapy (VMAT), Intensity Modulated Radiotherapy (IMRT), and ThreeDimensional Conformal Radiation therapy (3DCRT) for post-mastectomy radiotherapy (PMRT) in Left breast cancer patients
Purpose: To evaluate the difference in planning target volume (PTV) coverage and dose to the organs at risk
(OAR) by using three different planning methods for the same patient-Vol...
On Optimization of Mixed Photon Energies in Volumetric Modulated Arc Therapy
On Optimization of Mixed Photon Energies in Volumetric Modulated Arc Therapy
<p>This dissertation investigates the dosimetric influence of mixed photon beams in volumetric modulated arc therapy (VMAT) for prostate cancer and presents new algorithmic f...
On Optimization of Mixed Photon Energies in Volumetric Modulated Arc Therapy
On Optimization of Mixed Photon Energies in Volumetric Modulated Arc Therapy
<p>This dissertation investigates the dosimetric influence of mixed photon beams in volumetric modulated arc therapy (VMAT) for prostate cancer and presents new algorithmic f...