Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

SU‐F‐T‐131: No Increase in Biological Effectiveness Through Collimator Scattered Low Energy Protons

View through CrossRef
Purpose:To reduce the lateral penumbra of low‐energy proton beams, brass collimators are often used in spot‐scanning proton therapy (SSPT). This study investigates the increase in biological effectiveness through collimator scattered protons in SSPT.Methods:The SSPT system of the Hokkaido University Hospital Proton Beam Therapy Center, which consists of a scanning nozzle, a 2‐cm thick brass collimator, and a 4‐cm thick energy absorber, was simulated with our validated Geant4 Monte Carlo code (ver. 9.3). A water phantom was irradiated with proton pencil beams of 76, 110, and 143 MeV. The tested collimator opening areas (COA) were 5×5, 10×10, and 15×15 cm2. Comparisons were made among the dose‐averaged LET values of protons that hit the collimators (LETDColl), protons that did not hit the collimators (LETDNoColl), and all protons (LETDTotal). X‐ray equivalent doses (Deq) were calculated using the linear‐quadratic model with LETDNoColl and LETDTotal, and their maximum difference was determined over regions where the physical dose was greater than 10% of the peak dose of 2 Gy.Results:The ratio of the dose contribution of collimator scattered protons to that of all protons, defined as λ, was large at high proton energies and large COAs. The maximum λ value ranged from 3% (76 MeV, 5×5 cm2) to 29% (143 MeV, 15×15 cm2). Moreover, a large difference between LETDColl and LETDNoColl was only found in regions where λ was below 20% (ΔLETD > 2 keV/µm) and 8% (ΔLETD > 5 keV/µm). Consequently, the maximum difference between LETDNoColl and LETDTotal was as small as 0.8 keV/µm in all simulated voxels, and the difference of Deq reached a maximum of 1.5% that of the peak dose obtained at the water surface with a 76 MeV beam.Conclusion:Although collimator scattered protons have high LET, they only increase the physical dose, not the biological effectiveness.
Title: SU‐F‐T‐131: No Increase in Biological Effectiveness Through Collimator Scattered Low Energy Protons
Description:
Purpose:To reduce the lateral penumbra of low‐energy proton beams, brass collimators are often used in spot‐scanning proton therapy (SSPT).
This study investigates the increase in biological effectiveness through collimator scattered protons in SSPT.
Methods:The SSPT system of the Hokkaido University Hospital Proton Beam Therapy Center, which consists of a scanning nozzle, a 2‐cm thick brass collimator, and a 4‐cm thick energy absorber, was simulated with our validated Geant4 Monte Carlo code (ver.
9.
3).
A water phantom was irradiated with proton pencil beams of 76, 110, and 143 MeV.
The tested collimator opening areas (COA) were 5×5, 10×10, and 15×15 cm2.
Comparisons were made among the dose‐averaged LET values of protons that hit the collimators (LETDColl), protons that did not hit the collimators (LETDNoColl), and all protons (LETDTotal).
X‐ray equivalent doses (Deq) were calculated using the linear‐quadratic model with LETDNoColl and LETDTotal, and their maximum difference was determined over regions where the physical dose was greater than 10% of the peak dose of 2 Gy.
Results:The ratio of the dose contribution of collimator scattered protons to that of all protons, defined as λ, was large at high proton energies and large COAs.
The maximum λ value ranged from 3% (76 MeV, 5×5 cm2) to 29% (143 MeV, 15×15 cm2).
Moreover, a large difference between LETDColl and LETDNoColl was only found in regions where λ was below 20% (ΔLETD > 2 keV/µm) and 8% (ΔLETD > 5 keV/µm).
Consequently, the maximum difference between LETDNoColl and LETDTotal was as small as 0.
8 keV/µm in all simulated voxels, and the difference of Deq reached a maximum of 1.
5% that of the peak dose obtained at the water surface with a 76 MeV beam.
Conclusion:Although collimator scattered protons have high LET, they only increase the physical dose, not the biological effectiveness.

Related Results

Dynamic collimator trajectory algorithm for multiple metastases dynamic conformal arc treatment planning
Dynamic collimator trajectory algorithm for multiple metastases dynamic conformal arc treatment planning
PurposeTo develop an algorithm for dynamic collimator positioning to optimize beam's eye view (BEV) fitting of targets in dynamic conformal arc (DCA)‐based radiotherapy procedures,...
Physical and biological impacts of collimator‐scattered protons in spot‐scanning proton therapy
Physical and biological impacts of collimator‐scattered protons in spot‐scanning proton therapy
AbstractTo improve the penumbra of low‐energy beams used in spot‐scanning proton therapy, various collimation systems have been proposed and used in clinics. In this paper, focused...
Levels and behaviour of radionuclides in water treatment plants : the case of the Barcelona metropolitan area urban water cycle
Levels and behaviour of radionuclides in water treatment plants : the case of the Barcelona metropolitan area urban water cycle
The Barcelona metropolitan area (BMA; 3.2 M inhabitants) has an integrated urban water cycle management. Different type of treatment plants are located along the drinking, sewerage...
Practical collimator optimization in the management of prostate IMRT planning: A feasibility study
Practical collimator optimization in the management of prostate IMRT planning: A feasibility study
AbstractThe objective of this study was to evaluate the delivery efficiency of intensity modulated radiation therapy (IMRT) with a non-zero collimator rotation approach compared to...
WE‐AB‐209‐06: Dynamic Collimator Trajectory Algorithm for Use in VMAT Treatment Deliveries
WE‐AB‐209‐06: Dynamic Collimator Trajectory Algorithm for Use in VMAT Treatment Deliveries
Purpose:To develop advanced dynamic collimator positioning algorithms for optimal beam's‐eye‐view (BEV) fitting of targets in VMAT procedures, including multiple metastases stereot...
Radial dependence of ionization losses of protons of the Earth's radiation belts
Radial dependence of ionization losses of protons of the Earth's radiation belts
Abstract. Coulomb losses and charge exchange of protons are considered in detail. On the basis of modern models of the plasmasphere and the exosphere, the radial dependences of the...
Isolation, characterization and semi-synthesis of natural products dimeric amide alkaloids
Isolation, characterization and semi-synthesis of natural products dimeric amide alkaloids
 Isolation, characterization of natural products dimeric amide alkaloids from roots of the Piper chaba Hunter. The synthesis of these products using intermolecular [4+2] cycloaddit...
Ion velocity distribution functions at a low activity comet
Ion velocity distribution functions at a low activity comet
We study the transition period of induced comet magnetospheres between the simple deflection of the solar wind due to mass loading and a fully developed bow shock. We present exper...

Back to Top