Practical collimator optimization in the management of prostate IMRT planning: A feasibility study
View through CrossRef
AbstractThe objective of this study was to evaluate the delivery efficiency of intensity modulated radiation therapy (IMRT) with a non-zero collimator rotation approach compared to conventional planning IMRT in the management of prostate carcinoma. Inverse plans, created using conventional collimator angle 0° (CA0) for eight prostate patients, were compared to plans using collimator angle 70° (CA70) for all fields and also with plans utilizing an automatic collimator angle optimization tool (CAopt) for each field. Results demonstrate that IMRT plans created with rotational collimator techniques can produce comparable dose distributions to standard CA0 plans. The rotational collimator approach significantly reduced the total number of monitor units (MU) by 6% (p value = 0.027) and 9% (p value = 0.003) for CA70 and CAopt, respectively. The mean monitor units for CA0, CA70 and CAopt were 635 ± 107 MU, 597 ± 96 MU and 587 ± 104 MU, respectively. The mean peripheral dose was significantly increased with CA70 against CA0 (p value < 0.001) despite reduced monitor units. Collimator optimization resulted in reduction in monitor units and peripheral dose. The number of monitor units are reduced with the rotational collimator approach, which results in reduced delivery time. However, we conclude that peripheral dose should be analyzed when assessing monitor unit differences in IMRT plans.
Cambridge University Press (CUP)
Title: Practical collimator optimization in the management of prostate IMRT planning: A feasibility study
Description:
AbstractThe objective of this study was to evaluate the delivery efficiency of intensity modulated radiation therapy (IMRT) with a non-zero collimator rotation approach compared to conventional planning IMRT in the management of prostate carcinoma.
Inverse plans, created using conventional collimator angle 0° (CA0) for eight prostate patients, were compared to plans using collimator angle 70° (CA70) for all fields and also with plans utilizing an automatic collimator angle optimization tool (CAopt) for each field.
Results demonstrate that IMRT plans created with rotational collimator techniques can produce comparable dose distributions to standard CA0 plans.
The rotational collimator approach significantly reduced the total number of monitor units (MU) by 6% (p value = 0.
027) and 9% (p value = 0.
003) for CA70 and CAopt, respectively.
The mean monitor units for CA0, CA70 and CAopt were 635 ± 107 MU, 597 ± 96 MU and 587 ± 104 MU, respectively.
The mean peripheral dose was significantly increased with CA70 against CA0 (p value < 0.
001) despite reduced monitor units.
Collimator optimization resulted in reduction in monitor units and peripheral dose.
The number of monitor units are reduced with the rotational collimator approach, which results in reduced delivery time.
However, we conclude that peripheral dose should be analyzed when assessing monitor unit differences in IMRT plans.
Related Results
Dosimetric comparison of 3DCRT and IMRT in radical chemoradiotherapy of squamous cell carcinoma esophagus
Dosimetric comparison of 3DCRT and IMRT in radical chemoradiotherapy of squamous cell carcinoma esophagus
ABSTRACT
Background:
Radical chemoradiation is the standard of treatment for locally advanced squamous cell carcinoma of esophagus and for patien...
Dynamic collimator trajectory algorithm for multiple metastases dynamic conformal arc treatment planning
Dynamic collimator trajectory algorithm for multiple metastases dynamic conformal arc treatment planning
PurposeTo develop an algorithm for dynamic collimator positioning to optimize beam's eye view (BEV) fitting of targets in dynamic conformal arc (DCA)‐based radiotherapy procedures,...
Dosimetric comparative study of Volumetric Modulated Arc Therapy (VMAT), Intensity Modulated Radiotherapy (IMRT), and ThreeDimensional Conformal Radiation therapy (3DCRT) for post-mastectomy radiotherapy (PMRT) in Left breast cancer patients
Dosimetric comparative study of Volumetric Modulated Arc Therapy (VMAT), Intensity Modulated Radiotherapy (IMRT), and ThreeDimensional Conformal Radiation therapy (3DCRT) for post-mastectomy radiotherapy (PMRT) in Left breast cancer patients
Purpose: To evaluate the difference in planning target volume (PTV) coverage and dose to the organs at risk
(OAR) by using three different planning methods for the same patient-Vol...
Abstract 5758: Deletions of olfactomedin 4 gene is associated with progression of prostate cancer
Abstract 5758: Deletions of olfactomedin 4 gene is associated with progression of prostate cancer
Abstract
The human olfactomedin 4 gene (OLFM4) encodes an olfactomedin-related glycoprotein, which our group first cloned and characterized in myeloid cells and mapp...
SU‐GG‐T‐572: Are Constant Dose Rate VMAT Plans Clinically Acceptable? — A Site‐By‐Site Plan Comparison Study
SU‐GG‐T‐572: Are Constant Dose Rate VMAT Plans Clinically Acceptable? — A Site‐By‐Site Plan Comparison Study
Purpose: To evaluate the adequacy of constant dose rate (CDR) VMAT plans for clinical use of commonly treated sites. The clinical acceptability of CDR VMAT plans was evaluated base...
Abstract 4602: Clinicopathological and genetic features of prostate cancer in Algerian patients: First report
Abstract 4602: Clinicopathological and genetic features of prostate cancer in Algerian patients: First report
Abstract
Background: Prostate cancer is the second most frequent malignancy (after lung cancer) in men worldwide. It is the third most common cancer in men in Algeri...
Ten-Year Outcomes of IMRT With Chemotherapy Versus IMRT Alone for Stage Ⅱ-Ⅳa Nasopharyngeal Carcinoma: A Retrospective Study
Ten-Year Outcomes of IMRT With Chemotherapy Versus IMRT Alone for Stage Ⅱ-Ⅳa Nasopharyngeal Carcinoma: A Retrospective Study
Abstract
Background
Concurrent chemoradiotherapy (CCRT) is the cornerstone of treatment for patients with locoregionally advanced nasopharyngeal carcinoma (NPC). However, ...
Dose escalation with high-dose-3D-conformal/IMRT (HD-3D-CRT/IMRT) compared with low-dose 3D-conformal/IMRT plus HDR brachytherapy (LD-3D-CRT/IMRT+HDR-B) for intermediate- or high-risk prostate cancer: Disease control, survival, and toxicity.
Dose escalation with high-dose-3D-conformal/IMRT (HD-3D-CRT/IMRT) compared with low-dose 3D-conformal/IMRT plus HDR brachytherapy (LD-3D-CRT/IMRT+HDR-B) for intermediate- or high-risk prostate cancer: Disease control, survival, and toxicity.
169 Background: To report early and late toxicity and biochemical outcome in a prospective series of 1,465 patients with intermediate- or high-risk clinically localized prostate c...