Practical collimator optimization in the management of prostate IMRT planning: A feasibility study
View through CrossRef
AbstractThe objective of this study was to evaluate the delivery efficiency of intensity modulated radiation therapy (IMRT) with a non-zero collimator rotation approach compared to conventional planning IMRT in the management of prostate carcinoma. Inverse plans, created using conventional collimator angle 0° (CA0) for eight prostate patients, were compared to plans using collimator angle 70° (CA70) for all fields and also with plans utilizing an automatic collimator angle optimization tool (CAopt) for each field. Results demonstrate that IMRT plans created with rotational collimator techniques can produce comparable dose distributions to standard CA0 plans. The rotational collimator approach significantly reduced the total number of monitor units (MU) by 6% (p value = 0.027) and 9% (p value = 0.003) for CA70 and CAopt, respectively. The mean monitor units for CA0, CA70 and CAopt were 635 ± 107 MU, 597 ± 96 MU and 587 ± 104 MU, respectively. The mean peripheral dose was significantly increased with CA70 against CA0 (p value < 0.001) despite reduced monitor units. Collimator optimization resulted in reduction in monitor units and peripheral dose. The number of monitor units are reduced with the rotational collimator approach, which results in reduced delivery time. However, we conclude that peripheral dose should be analyzed when assessing monitor unit differences in IMRT plans.
Cambridge University Press (CUP)
Title: Practical collimator optimization in the management of prostate IMRT planning: A feasibility study
Description:
AbstractThe objective of this study was to evaluate the delivery efficiency of intensity modulated radiation therapy (IMRT) with a non-zero collimator rotation approach compared to conventional planning IMRT in the management of prostate carcinoma.
Inverse plans, created using conventional collimator angle 0° (CA0) for eight prostate patients, were compared to plans using collimator angle 70° (CA70) for all fields and also with plans utilizing an automatic collimator angle optimization tool (CAopt) for each field.
Results demonstrate that IMRT plans created with rotational collimator techniques can produce comparable dose distributions to standard CA0 plans.
The rotational collimator approach significantly reduced the total number of monitor units (MU) by 6% (p value = 0.
027) and 9% (p value = 0.
003) for CA70 and CAopt, respectively.
The mean monitor units for CA0, CA70 and CAopt were 635 ± 107 MU, 597 ± 96 MU and 587 ± 104 MU, respectively.
The mean peripheral dose was significantly increased with CA70 against CA0 (p value < 0.
001) despite reduced monitor units.
Collimator optimization resulted in reduction in monitor units and peripheral dose.
The number of monitor units are reduced with the rotational collimator approach, which results in reduced delivery time.
However, we conclude that peripheral dose should be analyzed when assessing monitor unit differences in IMRT plans.
Related Results
Metaheuristic-Based IMRT Optimization for Lung Cancer Treatment under Respiratory Motion
Metaheuristic-Based IMRT Optimization for Lung Cancer Treatment under Respiratory Motion
Introduction: Intensity-Modulated Radiation Therapy (IMRT) is a widely adopted cancer treatment technique due to its precision in delivering radiation doses to tumors while minimiz...
Dosimetric comparison of 3DCRT and IMRT in radical chemoradiotherapy of squamous cell carcinoma esophagus
Dosimetric comparison of 3DCRT and IMRT in radical chemoradiotherapy of squamous cell carcinoma esophagus
ABSTRACT
Background:
Radical chemoradiation is the standard of treatment for locally advanced squamous cell carcinoma of esophagus and for patien...
Dynamic collimator trajectory algorithm for multiple metastases dynamic conformal arc treatment planning
Dynamic collimator trajectory algorithm for multiple metastases dynamic conformal arc treatment planning
PurposeTo develop an algorithm for dynamic collimator positioning to optimize beam's eye view (BEV) fitting of targets in dynamic conformal arc (DCA)‐based radiotherapy procedures,...
Dosimetric comparative study of Volumetric Modulated Arc Therapy (VMAT), Intensity Modulated Radiotherapy (IMRT), and ThreeDimensional Conformal Radiation therapy (3DCRT) for post-mastectomy radiotherapy (PMRT) in Left breast cancer patients
Dosimetric comparative study of Volumetric Modulated Arc Therapy (VMAT), Intensity Modulated Radiotherapy (IMRT), and ThreeDimensional Conformal Radiation therapy (3DCRT) for post-mastectomy radiotherapy (PMRT) in Left breast cancer patients
Purpose: To evaluate the difference in planning target volume (PTV) coverage and dose to the organs at risk
(OAR) by using three different planning methods for the same patient-Vol...
SU‐GG‐T‐211: An Independent MU Calculation Program for Dynamic IMRT
SU‐GG‐T‐211: An Independent MU Calculation Program for Dynamic IMRT
Purpose: The performance of an independent monitor unit calculation program is evaluated to verify the monitor unit (MU) for dynamic IMRT fields. The MU calculation program runs on...
Holmium laser enucleation of the prostate versus bipolar transurethral enucleation of the prostate in management of benign prostatic hyperplasia: A randomized controlled trial
Holmium laser enucleation of the prostate versus bipolar transurethral enucleation of the prostate in management of benign prostatic hyperplasia: A randomized controlled trial
Objective
To evaluate the safety, efficacy and cost‐effectiveness of holmium enucleation of the prostate and bipolar transurethral enucleation of the prostate.
...
SU‐E‐T‐02: Radiobiological Comparison of Two Treatment Schemas in IMRT Prostate Radiotherapy
SU‐E‐T‐02: Radiobiological Comparison of Two Treatment Schemas in IMRT Prostate Radiotherapy
Purpose: Different fractionation schemas are used for the treatment of prostate with IMRT. Due to the low α/β of prostate hypofractionated schemas are achieving more importance. Th...
Abstract 5758: Deletions of olfactomedin 4 gene is associated with progression of prostate cancer
Abstract 5758: Deletions of olfactomedin 4 gene is associated with progression of prostate cancer
Abstract
The human olfactomedin 4 gene (OLFM4) encodes an olfactomedin-related glycoprotein, which our group first cloned and characterized in myeloid cells and mapp...