SU‐E‐T‐47: A Monte Carlo Model of a Spot Scanning Proton Beam Based On a Synchrotron Proton Therapy Accelerator
View through CrossRef
Purpose:To build the model of a spot scanning proton beam for the dose calculation of a synchrotron proton therapy accelerator, which is capable of accelerating protons from 50 up to 221 MeV.Methods:The spot scanning beam nozzle is modeled using TOPAS code, a simulation tool based on Geant4.9.6. The model contained a beam pipe vacuum window, a beam profile monitor, a drift chamber, two plane‐parallel ionization chambers, and a spot‐position monitor consisted of a multiwire ionization chamber. A water phantom is located with its upstream surface at the isocenter plane. The initial proton beam energy and anglar deflection are modeled using a Gaussian distribution with FWHM (Full Widths at Half Maximum) deponding on its beam energy. The phase space file (PSF) on a virtual surface located at the center between the two magnets is recorded. PSF is used to analyze the pencil beam features and offset the pencil beam position. The source model parameters are verificated by fitting the simulated Result to the measurement.Results:The simulated percentage depth dose (PDD) and lateral profiles of scanning pencil beams of various incident proton energies are verificated to the measurement. Generally the distance to agreement (DTA) of Bragg peaks is less than 0.2cm. The FWHM of Gaussian anglar distribution was adjusted to fit the lateral profile difference between the simulation and the measurement to less than 2∼3cm.Conclusion:A Monte Carlo model of a spot scanning proton beam was bullt based on a synchrotron proton therapy accelerator. This scanning pencil beam model will be as a block to build the broad proton beam as a proton TPS dose verification tool.
Title: SU‐E‐T‐47: A Monte Carlo Model of a Spot Scanning Proton Beam Based On a Synchrotron Proton Therapy Accelerator
Description:
Purpose:To build the model of a spot scanning proton beam for the dose calculation of a synchrotron proton therapy accelerator, which is capable of accelerating protons from 50 up to 221 MeV.
Methods:The spot scanning beam nozzle is modeled using TOPAS code, a simulation tool based on Geant4.
9.
6.
The model contained a beam pipe vacuum window, a beam profile monitor, a drift chamber, two plane‐parallel ionization chambers, and a spot‐position monitor consisted of a multiwire ionization chamber.
A water phantom is located with its upstream surface at the isocenter plane.
The initial proton beam energy and anglar deflection are modeled using a Gaussian distribution with FWHM (Full Widths at Half Maximum) deponding on its beam energy.
The phase space file (PSF) on a virtual surface located at the center between the two magnets is recorded.
PSF is used to analyze the pencil beam features and offset the pencil beam position.
The source model parameters are verificated by fitting the simulated Result to the measurement.
Results:The simulated percentage depth dose (PDD) and lateral profiles of scanning pencil beams of various incident proton energies are verificated to the measurement.
Generally the distance to agreement (DTA) of Bragg peaks is less than 0.
2cm.
The FWHM of Gaussian anglar distribution was adjusted to fit the lateral profile difference between the simulation and the measurement to less than 2∼3cm.
Conclusion:A Monte Carlo model of a spot scanning proton beam was bullt based on a synchrotron proton therapy accelerator.
This scanning pencil beam model will be as a block to build the broad proton beam as a proton TPS dose verification tool.
Related Results
MO‐SAM‐BRB‐02: Proton Physics and Technology
MO‐SAM‐BRB‐02: Proton Physics and Technology
The dose localization advantages of proton beams derive primarily from the Bragg peak in the proton stopping distribution. Therefore, the potential clinical gains expected form pro...
Monte-Carlo Simulation mit Risk Kit (Monte-Carlo Simulation with Risk Kit)
Monte-Carlo Simulation mit Risk Kit (Monte-Carlo Simulation with Risk Kit)
<b>German Abstract:</b> Monte-Carlo Simulationen spielen eine immer bedeutender werdende Rolle der Finanzwirtschaft, den Sozialwissenschaften und im Risk Management. Mo...
Benchmarking a GATE/Geant4 Monte Carlo model for proton beams in magnetic fields
Benchmarking a GATE/Geant4 Monte Carlo model for proton beams in magnetic fields
PurposeMagnetic resonance guidance in proton therapy (MRPT) is expected to improve its current performance. The combination of magnetic fields with clinical proton beam lines poses...
Monte Carlo methods: barrier option pricing with stable Greeks and multilevel Monte Carlo learning
Monte Carlo methods: barrier option pricing with stable Greeks and multilevel Monte Carlo learning
For discretely observed barrier options, there exists no closed solution under the Black-Scholes model. Thus, it is often helpful to use Monte Carlo simulations, which are easily a...
TH‐E‐ValA‐02: Simultaneous Multi‐Pencil Fan‐Beam‐Based Intensity‐Modulated Proton Therapy.
TH‐E‐ValA‐02: Simultaneous Multi‐Pencil Fan‐Beam‐Based Intensity‐Modulated Proton Therapy.
Purpose: Intensity‐modulated proton therapy (IMPT) will improve the conformality of proton radiotherapy while preserving target homogeneity and low integral dose characteristics. I...
Analisis Harga Opsi Beli Tipe Eropa dengan Metode Antithetic Variate dari Monte Carlo
Analisis Harga Opsi Beli Tipe Eropa dengan Metode Antithetic Variate dari Monte Carlo
Stock options is one of the derivative products of stocks. The purpose of this study is to analyze the price of European type call options using the antithetic variate method from ...
TURN-BY-TURN BEAM EXTRACTION DURING ACCELERATION IN A SYNCHROTRON
TURN-BY-TURN BEAM EXTRACTION DURING ACCELERATION IN A SYNCHROTRON
A synchrotron to accelerate protons or carbon ions for medical applications is being designed at Brookhaven National Laboratory (BNL). Single beam bunches with maximum beam energy ...
A Comparative Study of Pyrenophora Teres Drechs. F. Teres and Pyrenophora Teres Drechs. F. Maculata Smedeg. Cause of "Net" and "Spot" Type Net Blotch Respectively on New Zealand Barley
A Comparative Study of Pyrenophora Teres Drechs. F. Teres and Pyrenophora Teres Drechs. F. Maculata Smedeg. Cause of "Net" and "Spot" Type Net Blotch Respectively on New Zealand Barley
<p>Net blotch is caused by Pyrenophora teres Drechs. (stat. conid. Drechslera teres (Sacc.) Shoem., syn. Helminthosporium teres Sacc). P. teres produces symptoms which appear...