Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Research and Evaluation for Passive Safety System in Low Pressure Reactor

View through CrossRef
Low pressure reactor is a small size advanced reactor with power of 180 MWt, which is under development at Nuclear Power Institute of China. In order to assess the ability and feasibility of passive safety system, several tests have been implemented on the passive safety system (PSS) test facility. During the LOCA and SBO accident, the adequate core cooling is provided by the performance of passive safety system. In addition the best-estimate thermal hydraulic code, CATHARE V2.1, has been assessed against cold leg LOCA test. The calculation results show that CATHARE is in a satisfactory agreement with the test for the steady state and transient test.
Title: Research and Evaluation for Passive Safety System in Low Pressure Reactor
Description:
Low pressure reactor is a small size advanced reactor with power of 180 MWt, which is under development at Nuclear Power Institute of China.
In order to assess the ability and feasibility of passive safety system, several tests have been implemented on the passive safety system (PSS) test facility.
During the LOCA and SBO accident, the adequate core cooling is provided by the performance of passive safety system.
In addition the best-estimate thermal hydraulic code, CATHARE V2.
1, has been assessed against cold leg LOCA test.
The calculation results show that CATHARE is in a satisfactory agreement with the test for the steady state and transient test.

Related Results

Evaluating Effects of Culture and Language on Safety
Evaluating Effects of Culture and Language on Safety
This paper (SPE 54448) was revised for publication from paper SPE 48891, prepared for the 1998 SPE International Conference and Exhibition held in Beijing, 2–6 November. Original m...
Factors Influencing Patient Safety Management Behaviors in Nursing Students
Factors Influencing Patient Safety Management Behaviors in Nursing Students
The objective of this study is to identify the critical thinking Disposition, problem-solving processes, safety motivation, patient safety management knowledge, attitudes towards p...
REACTOR OPERATIONAL EXPERIENCE REVIEW AND ANALYSIS BASED ON UN-INTENDED REACTOR TRIP DATA
REACTOR OPERATIONAL EXPERIENCE REVIEW AND ANALYSIS BASED ON UN-INTENDED REACTOR TRIP DATA
To enhance the safety and reliability of a new reactor, human factors should be integrated into its design process. The experimental power reactor (RDE) currently being developed i...
Analyzing Well Performance VII
Analyzing Well Performance VII
Introduction Analyzing well performance is an important step toward increasing profits by improving production techniques. The analysis is made by field tests and...
Transient Analysis of the Loss of Heat Sink Accident in a New Type of Megawatt Heat Pipe Reactor
Transient Analysis of the Loss of Heat Sink Accident in a New Type of Megawatt Heat Pipe Reactor
Abstract Heat pipe reactors are one of the ideal reactor types for Unmanned Underwater Vehicles (UUVs) due to high energy density, long lifecycle, modularity, and co...
Simulation and Analysis for Hualong Reactor Advanced Integrated Test Facility Based on RELAP5
Simulation and Analysis for Hualong Reactor Advanced Integrated Test Facility Based on RELAP5
Abstract Hualong One and its subsequent rectors are the third-generation pressurized water reactor (PWR) and constructed by the China National Nuclear Corporation (C...
Scaling Analysis of Passive Heat Exchanger Under Station Blackout Accident
Scaling Analysis of Passive Heat Exchanger Under Station Blackout Accident
Station blackout accidents increasingly become the focus of research in the field of nuclear safety after Japan’s Fukushima nuclear plant accident in March 2011. Core decay heat un...
EPD Electronic Pathogen Detection v1
EPD Electronic Pathogen Detection v1
Electronic pathogen detection (EPD) is a non - invasive, rapid, affordable, point- of- care test, for Covid 19 resulting from infection with SARS-CoV-2 virus. EPD scanning techno...

Back to Top