REACTOR OPERATIONAL EXPERIENCE REVIEW AND ANALYSIS BASED ON UN-INTENDED REACTOR TRIP DATA

View through CrossRef
To enhance the safety and reliability of a new reactor, human factors should be integrated into its design process. The experimental power reactor (RDE) currently being developed in Indonesia needs to include human factors in the design process. One approach to incorporate human factors into design is by considering reactor operational experience data. This paper reviews and analyses the operational experience data of RSG-GAS reactor. The operational experience data of RSG-GAS reactor with 40,435 hours of total operation time spanning from 2003 to 2013 was used as a base in the study. In depth analysis on human factors was applied to the primary cooling system using Human Factors Analysis and Classification System-HFACS method. An amount of 289 un-intended trips were found in the observation data period. Most of un-intended trip were caused by external factors (38%). A review on the primary and secondary cooling system operational data showed that 3.11% of un-intended reactor trip occurrence causes were associated with human failure. Most suspected human failure/human error corresponds to the pump maintenance task which is classified as A action category. Analysis on the cooling system based on HFACS showed that the challenges to the human factors are related to unsafe acts, preconditions of unsafe acts, and unsafe supervision. The result reaffirm that human factors should be treated appropriately in the design of reactor equipment and operation procedure as well.Keywords: reactor operation experience, research reactor, human factors, reactor trip
Title: REACTOR OPERATIONAL EXPERIENCE REVIEW AND ANALYSIS BASED ON UN-INTENDED REACTOR TRIP DATA
Description:
To enhance the safety and reliability of a new reactor, human factors should be integrated into its design process.
The experimental power reactor (RDE) currently being developed in Indonesia needs to include human factors in the design process.
One approach to incorporate human factors into design is by considering reactor operational experience data.
This paper reviews and analyses the operational experience data of RSG-GAS reactor.
The operational experience data of RSG-GAS reactor with 40,435 hours of total operation time spanning from 2003 to 2013 was used as a base in the study.
In depth analysis on human factors was applied to the primary cooling system using Human Factors Analysis and Classification System-HFACS method.
An amount of 289 un-intended trips were found in the observation data period.
Most of un-intended trip were caused by external factors (38%).
A review on the primary and secondary cooling system operational data showed that 3.
11% of un-intended reactor trip occurrence causes were associated with human failure.
Most suspected human failure/human error corresponds to the pump maintenance task which is classified as A action category.
Analysis on the cooling system based on HFACS showed that the challenges to the human factors are related to unsafe acts, preconditions of unsafe acts, and unsafe supervision.
The result reaffirm that human factors should be treated appropriately in the design of reactor equipment and operation procedure as well.
Keywords: reactor operation experience, research reactor, human factors, reactor trip.

Related Results

Evaluating the Science to Inform the Physical Activity Guidelines for Americans Midcourse Report
Evaluating the Science to Inform the Physical Activity Guidelines for Americans Midcourse Report
Abstract The Physical Activity Guidelines for Americans (Guidelines) advises older adults to be as active as possible. Yet, despite the well documented benefits of physical activi...
FAKTOR PEMILIHAN MODA PENGUNJUNG CAR-FREE DAY KOTA BANDUNG
FAKTOR PEMILIHAN MODA PENGUNJUNG CAR-FREE DAY KOTA BANDUNG
This paper aims to reveal the dimension underlying variables that affect the trip makers; mode choice to reach Car-Free Day location, taking Bandung as a case study. Twelve variabl...
ANALISIS PENGATURAN POSISI CONTROL RODS PADA KONSEP REAKTOR DAYA EKSPERIMENTAL INDONESIA PASCA REACTOR SCRAM
ANALISIS PENGATURAN POSISI CONTROL RODS PADA KONSEP REAKTOR DAYA EKSPERIMENTAL INDONESIA PASCA REACTOR SCRAM
ANALISISPENGATURAN POSISI CONTROL RODS PADA KONSEP REAKTOR DAYA EKSPERIMENTAL INDONESIA PASCA REACTOR SCRAM POST REACTOR SCRAM CONTROL RODS POSITION ADJUSTMENT ANALYSIS FOR THE IN...
Eliminación biológica de nutrientes en un ARU de baja carga orgánica mediante el proceso VIP
Eliminación biológica de nutrientes en un ARU de baja carga orgánica mediante el proceso VIP
El objetivo principal de esta tesis doctoral es profundizar en el conocimiento de los procesos biológicos responsables de la eliminación simultánea de nitrógeno y fósforo en un ARU...
Properties and application of TRIP‐steel in sheet metal forming
Properties and application of TRIP‐steel in sheet metal forming
A further development of dual‐phase‐steels are represented by TRIP (transformation induced plasticity) ‐steels. TRIP‐steels contain austenite, which is metastable at room temperatu...
Trip Generation at Fast–Food Restaurants in Johor Bahru, Malaysia
Trip Generation at Fast–Food Restaurants in Johor Bahru, Malaysia
Trip Generation rates are important for transportation engineers and planners in the Travel Demand Forecasting process as well as for Traffic Impact Studies. Trip generation by a g...
RELAP5 SIMULATION FOR SEVERE ACCIDENT ANALYSIS OF RSG-GAS REACTOR
RELAP5 SIMULATION FOR SEVERE ACCIDENT ANALYSIS OF RSG-GAS REACTOR
The research reactor in the world is to be known safer than power reactor due to its simpler design related to the core and operational chararacteristics. Nevertheless, potential h...
INFORMATION PROCESSING IN THE REACTOR PROTECTION SYSTEMS OF HIGH TEMPERATURE GAS-COOLED REACTORS
INFORMATION PROCESSING IN THE REACTOR PROTECTION SYSTEMS OF HIGH TEMPERATURE GAS-COOLED REACTORS
Reactor protection systems (RPS) transform process variable signals from the sensors into initiation and actuation signals to trip the reactor if the signal's value exceeds the pre...