Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Scaling Analysis of Passive Heat Exchanger Under Station Blackout Accident

View through CrossRef
Station blackout accidents increasingly become the focus of research in the field of nuclear safety after Japan’s Fukushima nuclear plant accident in March 2011. Core decay heat under station blackout condition will be transferred by natural circulation occurring between core and passive heat exchanger for the nuclear plants incorporated passive safety design concept such as AP1000 or CAP1400. As a result, response of safety systems will differ in accident sequence and kind between passive safety plant and traditional plant. What is more, cooling capacity of passive heat exchanger (PHX) which takes on heat sink has significant effect on performance of natural circulation in passive safety system. The safety need that characteristics of passive safety plant should be verified through integral experiment facility makes scaling analysis important in design or modification of experiment facility. Furthermore, scaling analysis of natural circulation phenomena under station blackout accident plays an important role in design verification, safety review verification or thermo-hydraulic program development. It not only determines the similar similarity criteria between the nuclear power plant prototype and test facility, but also provides technical basis for selecting different experiment schemes. As a part of scaling analysis on natural circulation phenomena for station blackout, the cooling capacity of PHX in test facility should be scaled properly and reasonably with conservatism. Therefore, scaling of passive residual heat removal (PRHR) heat exchanger under station blackout accident is investigated analytically in this paper. The analytical model for natural circulation in passive heat exchanger is established based on the performance characteristics of PRHR system in passive plant. By proper hypothesis and simplification, the governing equations for PHX are normalized using steady-state solutions, initial or boundary conditions. The similarity criteria that should be preserved between PHXs in test facility and prototype are finally obtained from non-dimensionalized equations. Furthermore, the distortion analysis for PHE design is also investigated based on the similarity criteria for selected scaling factors and parameters. The safety analysis based on models of nuclear power plant prototype and test facility is conducted on transient performance of designed PHX with PHX of prototype. The results show that: heat source number is the dominant similarity criteria for PHXs design under SBO condition. Requirements of Richardson number and friction number could be satisfied by resistance adjusting on test loop. The performance of PHX designed following heat source number requirement can better represent the transient response characteristics of prototype under SBO condition.
Title: Scaling Analysis of Passive Heat Exchanger Under Station Blackout Accident
Description:
Station blackout accidents increasingly become the focus of research in the field of nuclear safety after Japan’s Fukushima nuclear plant accident in March 2011.
Core decay heat under station blackout condition will be transferred by natural circulation occurring between core and passive heat exchanger for the nuclear plants incorporated passive safety design concept such as AP1000 or CAP1400.
As a result, response of safety systems will differ in accident sequence and kind between passive safety plant and traditional plant.
What is more, cooling capacity of passive heat exchanger (PHX) which takes on heat sink has significant effect on performance of natural circulation in passive safety system.
The safety need that characteristics of passive safety plant should be verified through integral experiment facility makes scaling analysis important in design or modification of experiment facility.
Furthermore, scaling analysis of natural circulation phenomena under station blackout accident plays an important role in design verification, safety review verification or thermo-hydraulic program development.
It not only determines the similar similarity criteria between the nuclear power plant prototype and test facility, but also provides technical basis for selecting different experiment schemes.
As a part of scaling analysis on natural circulation phenomena for station blackout, the cooling capacity of PHX in test facility should be scaled properly and reasonably with conservatism.
Therefore, scaling of passive residual heat removal (PRHR) heat exchanger under station blackout accident is investigated analytically in this paper.
The analytical model for natural circulation in passive heat exchanger is established based on the performance characteristics of PRHR system in passive plant.
By proper hypothesis and simplification, the governing equations for PHX are normalized using steady-state solutions, initial or boundary conditions.
The similarity criteria that should be preserved between PHXs in test facility and prototype are finally obtained from non-dimensionalized equations.
Furthermore, the distortion analysis for PHE design is also investigated based on the similarity criteria for selected scaling factors and parameters.
The safety analysis based on models of nuclear power plant prototype and test facility is conducted on transient performance of designed PHX with PHX of prototype.
The results show that: heat source number is the dominant similarity criteria for PHXs design under SBO condition.
Requirements of Richardson number and friction number could be satisfied by resistance adjusting on test loop.
The performance of PHX designed following heat source number requirement can better represent the transient response characteristics of prototype under SBO condition.

Related Results

ANALISIS EFEKTIVITAS LIQUID SECTION HEAT EXCHANGER DENGAN TUBE IN TUBE HEAT EXCHANGER DARI SISI APLIKATIF
ANALISIS EFEKTIVITAS LIQUID SECTION HEAT EXCHANGER DENGAN TUBE IN TUBE HEAT EXCHANGER DARI SISI APLIKATIF
Penelitian ini menjelaskan tentang aplikasidari LSHX yang lebih baik daripada jenis heat exchanger lainnyaagar penggunaan penukar kalor tipe ini lebih efektif dan dapat diaplikasik...
Design of Cross Flow Heat Exchanger Using Performance Charts
Design of Cross Flow Heat Exchanger Using Performance Charts
The manuscript reviews the various steps involved in the design of a cross flow heat exchanger. Performance charts describing the thermal performance of the heat exchanger in terms...
Plate heat exchanger – inertia flywheel performance in loss of flow transient
Plate heat exchanger – inertia flywheel performance in loss of flow transient
Abstract One of the most versatile types of heat exchangers used is the plate heat exchanger. It has principal advantages over other heat exchangers in that plates c...
Heat Exchanger Design and Optimization
Heat Exchanger Design and Optimization
Heat exchangers are devices that transfer heat energy between fluids by utilizing heat transfer modes of conduction and convection. The shell and tube heat exchanger configuration ...
Parametric Modeling and Economic Analysis of a 2MWth 3-Stream sCO2 Heat Exchanger
Parametric Modeling and Economic Analysis of a 2MWth 3-Stream sCO2 Heat Exchanger
Abstract This paper presents the design and cost optimization of a novel 2MWth 3-stream sCO2 plate-fin heat exchanger. This heat exchanger design is unique in that i...
Kaji efisiensi temperatur penukar panas dengan variasi aliran untuk aplikasi pengering
Kaji efisiensi temperatur penukar panas dengan variasi aliran untuk aplikasi pengering
Abstrak Heat exchanger atau alat penukar panas adalah alat-alat yang digunakan untuk mengubah temperatur fluida atau mengubah fasa fluida dengan cara mempertukarkan panasnya dengan...
Intelligent Monitoring and Diagnosis of CCWS Heat Exchanger For Nuclear Power Plant
Intelligent Monitoring and Diagnosis of CCWS Heat Exchanger For Nuclear Power Plant
Abstract Component Cooling Water System (CCWS) heat exchanger in nuclear power plant plays an important role in normal operation and accident condition. Because of t...
Analisis Kinerja Exhaust Gas Heat Exchanger Dengan Menggunakan Diagram Pareto
Analisis Kinerja Exhaust Gas Heat Exchanger Dengan Menggunakan Diagram Pareto
Heat Exchanger sebagai alat penukar kalor yang berfungsi untuk mengubah temperatur dan fasa suatu jenis fluida. Dalam penerapan heat exchanger terdapat permasalahan yang masih munc...

Back to Top