Javascript must be enabled to continue!
Scaling Analysis of Passive Heat Exchanger Under Station Blackout Accident
View through CrossRef
Station blackout accidents increasingly become the focus of research in the field of nuclear safety after Japan’s Fukushima nuclear plant accident in March 2011. Core decay heat under station blackout condition will be transferred by natural circulation occurring between core and passive heat exchanger for the nuclear plants incorporated passive safety design concept such as AP1000 or CAP1400. As a result, response of safety systems will differ in accident sequence and kind between passive safety plant and traditional plant. What is more, cooling capacity of passive heat exchanger (PHX) which takes on heat sink has significant effect on performance of natural circulation in passive safety system.
The safety need that characteristics of passive safety plant should be verified through integral experiment facility makes scaling analysis important in design or modification of experiment facility. Furthermore, scaling analysis of natural circulation phenomena under station blackout accident plays an important role in design verification, safety review verification or thermo-hydraulic program development. It not only determines the similar similarity criteria between the nuclear power plant prototype and test facility, but also provides technical basis for selecting different experiment schemes.
As a part of scaling analysis on natural circulation phenomena for station blackout, the cooling capacity of PHX in test facility should be scaled properly and reasonably with conservatism. Therefore, scaling of passive residual heat removal (PRHR) heat exchanger under station blackout accident is investigated analytically in this paper. The analytical model for natural circulation in passive heat exchanger is established based on the performance characteristics of PRHR system in passive plant. By proper hypothesis and simplification, the governing equations for PHX are normalized using steady-state solutions, initial or boundary conditions. The similarity criteria that should be preserved between PHXs in test facility and prototype are finally obtained from non-dimensionalized equations. Furthermore, the distortion analysis for PHE design is also investigated based on the similarity criteria for selected scaling factors and parameters. The safety analysis based on models of nuclear power plant prototype and test facility is conducted on transient performance of designed PHX with PHX of prototype. The results show that: heat source number is the dominant similarity criteria for PHXs design under SBO condition. Requirements of Richardson number and friction number could be satisfied by resistance adjusting on test loop. The performance of PHX designed following heat source number requirement can better represent the transient response characteristics of prototype under SBO condition.
American Society of Mechanical Engineers
Title: Scaling Analysis of Passive Heat Exchanger Under Station Blackout Accident
Description:
Station blackout accidents increasingly become the focus of research in the field of nuclear safety after Japan’s Fukushima nuclear plant accident in March 2011.
Core decay heat under station blackout condition will be transferred by natural circulation occurring between core and passive heat exchanger for the nuclear plants incorporated passive safety design concept such as AP1000 or CAP1400.
As a result, response of safety systems will differ in accident sequence and kind between passive safety plant and traditional plant.
What is more, cooling capacity of passive heat exchanger (PHX) which takes on heat sink has significant effect on performance of natural circulation in passive safety system.
The safety need that characteristics of passive safety plant should be verified through integral experiment facility makes scaling analysis important in design or modification of experiment facility.
Furthermore, scaling analysis of natural circulation phenomena under station blackout accident plays an important role in design verification, safety review verification or thermo-hydraulic program development.
It not only determines the similar similarity criteria between the nuclear power plant prototype and test facility, but also provides technical basis for selecting different experiment schemes.
As a part of scaling analysis on natural circulation phenomena for station blackout, the cooling capacity of PHX in test facility should be scaled properly and reasonably with conservatism.
Therefore, scaling of passive residual heat removal (PRHR) heat exchanger under station blackout accident is investigated analytically in this paper.
The analytical model for natural circulation in passive heat exchanger is established based on the performance characteristics of PRHR system in passive plant.
By proper hypothesis and simplification, the governing equations for PHX are normalized using steady-state solutions, initial or boundary conditions.
The similarity criteria that should be preserved between PHXs in test facility and prototype are finally obtained from non-dimensionalized equations.
Furthermore, the distortion analysis for PHE design is also investigated based on the similarity criteria for selected scaling factors and parameters.
The safety analysis based on models of nuclear power plant prototype and test facility is conducted on transient performance of designed PHX with PHX of prototype.
The results show that: heat source number is the dominant similarity criteria for PHXs design under SBO condition.
Requirements of Richardson number and friction number could be satisfied by resistance adjusting on test loop.
The performance of PHX designed following heat source number requirement can better represent the transient response characteristics of prototype under SBO condition.
Related Results
Parametric Modeling and Economic Analysis of a 2MWth 3-Stream sCO2 Heat Exchanger
Parametric Modeling and Economic Analysis of a 2MWth 3-Stream sCO2 Heat Exchanger
Abstract
This paper presents the design and cost optimization of a novel 2MWth 3-stream sCO2 plate-fin heat exchanger. This heat exchanger design is unique in that i...
Kaji efisiensi temperatur penukar panas dengan variasi aliran untuk aplikasi pengering
Kaji efisiensi temperatur penukar panas dengan variasi aliran untuk aplikasi pengering
Abstrak Heat exchanger atau alat penukar panas adalah alat-alat yang digunakan untuk mengubah temperatur fluida atau mengubah fasa fluida dengan cara mempertukarkan panasnya dengan...
Intelligent Monitoring and Diagnosis of CCWS Heat Exchanger For Nuclear Power Plant
Intelligent Monitoring and Diagnosis of CCWS Heat Exchanger For Nuclear Power Plant
Abstract
Component Cooling Water System (CCWS) heat exchanger in nuclear power plant plays an important role in normal operation and accident condition. Because of t...
Analisis Kinerja Exhaust Gas Heat Exchanger Dengan Menggunakan Diagram Pareto
Analisis Kinerja Exhaust Gas Heat Exchanger Dengan Menggunakan Diagram Pareto
Heat Exchanger sebagai alat penukar kalor yang berfungsi untuk mengubah temperatur dan fasa suatu jenis fluida. Dalam penerapan heat exchanger terdapat permasalahan yang masih munc...
Investigation of Latent Heat Thermal Energy Storage System for AirConditioning Applications
Investigation of Latent Heat Thermal Energy Storage System for AirConditioning Applications
In this study an experimental setup was constructed to investigate the solidification process of PCM using two different types of heat exchangers: pipe heat exchanger and horizonta...
Transient Analysis of the Loss of Heat Sink Accident in a New Type of Megawatt Heat Pipe Reactor
Transient Analysis of the Loss of Heat Sink Accident in a New Type of Megawatt Heat Pipe Reactor
Abstract
Heat pipe reactors are one of the ideal reactor types for Unmanned Underwater Vehicles (UUVs) due to high energy density, long lifecycle, modularity, and co...
Numerical Investigation of Power Generation Enhancement for Exhaust Heat Exchanger with Cylindrical Grooves in Thermoelectric Generator Systems
Numerical Investigation of Power Generation Enhancement for Exhaust Heat Exchanger with Cylindrical Grooves in Thermoelectric Generator Systems
<div class="section abstract"><div class="htmlview paragraph">For vehicle thermoelectric generator, heat would be directly transferred into electricity by thermoelectri...
Spiral Heat Exchanger Utilizing Dimpled Primary Surface
Spiral Heat Exchanger Utilizing Dimpled Primary Surface
Paper presents a small demonstrator of the heat exchanger technology based on spiral counter-flow arrangement of dimpled primary surfaces. The heat exchanger has been developed as ...