CLASP RETENTION USING VARIABLE UNDERCUT DEPTHS

View through CrossRef
Retentive force may be increased in deeper undercuts. Three clasps were examined for this hypothesis in order to analyze the retentive force change properties for each clasp design with increasing undercut depth only. A total of 36 cobalt-chromium clasps, using half-round pattern and standard casting technique were fabricated. Three groups of clasps; Rest-Plate-Akers system, half-half, and Akers were engaged in 3 increasing undercut depths (0.25, 0.35, and 0.5 mm) on natural premolars. The test model was stone duplicate of plastic replica. Clasp retentive force was measured using universal testing machine. The results showed that the retentive forces for the tested undercuts (0.25, 0.35 and 0.5mm) were 8.59±1.89, 14.74±2.70 and 15.21±1.17 N for Akers; 3.06±0.88, 4.26±0.29, and 5.9±0.53 for half-half; and 0.9±0.15, 2.06±0.60, 2.3±0.50 N for Rest-Plat-Akers system respectively. Besides, the retentive force for each clasp design increased in a different way with each incremental augmentation of undercut depth. As a conclusion, changing the undercut depth altered the retentive force of the used clasp. Therefore, a clasp chosen for a definite undercut depth also can be used for deeper undercut on the same abutment when higher retentive force is required with respect to the other indication criteria.
Title: CLASP RETENTION USING VARIABLE UNDERCUT DEPTHS
Description:
Retentive force may be increased in deeper undercuts.
Three clasps were examined for this hypothesis in order to analyze the retentive force change properties for each clasp design with increasing undercut depth only.
A total of 36 cobalt-chromium clasps, using half-round pattern and standard casting technique were fabricated.
Three groups of clasps; Rest-Plate-Akers system, half-half, and Akers were engaged in 3 increasing undercut depths (0.
25, 0.
35, and 0.
5 mm) on natural premolars.
The test model was stone duplicate of plastic replica.
Clasp retentive force was measured using universal testing machine.
The results showed that the retentive forces for the tested undercuts (0.
25, 0.
35 and 0.
5mm) were 8.
59±1.
89, 14.
74±2.
70 and 15.
21±1.
17 N for Akers; 3.
06±0.
88, 4.
26±0.
29, and 5.
9±0.
53 for half-half; and 0.
9±0.
15, 2.
06±0.
60, 2.
3±0.
50 N for Rest-Plat-Akers system respectively.
Besides, the retentive force for each clasp design increased in a different way with each incremental augmentation of undercut depth.
As a conclusion, changing the undercut depth altered the retentive force of the used clasp.
Therefore, a clasp chosen for a definite undercut depth also can be used for deeper undercut on the same abutment when higher retentive force is required with respect to the other indication criteria.

Related Results

EFFECT OF DESIGN CHANGING OF RING CLASP ON ITS RETENTIVE FORCE
EFFECT OF DESIGN CHANGING OF RING CLASP ON ITS RETENTIVE FORCE
Different designs of ring clasp were indicated in short or long span bounded saddle. However, few researches have been done to calculate their retentive absolute forces. The purpos...
Pengaruh Kepemimpinan Kepala Sekolah, Lingkungan Kerja, dan Sarana Pembelajaran terhadap Kinerja Guru Melalui Motivasi Kerja
Pengaruh Kepemimpinan Kepala Sekolah, Lingkungan Kerja, dan Sarana Pembelajaran terhadap Kinerja Guru Melalui Motivasi Kerja
Penelitian ini mengkaji pengaruh kepemimpinan kepala sekolah, lingkungan sekolah, dan sarana pembelajaran terhadap kinerja guru SMAS Reformasi Plus, dengan motivasi guru sebagai va...
Retention Evaluation of Implant-Supported Palateless Maxillary Overdentures Retained by PEEK Telescopic Attachment
Retention Evaluation of Implant-Supported Palateless Maxillary Overdentures Retained by PEEK Telescopic Attachment
Background: Retention and stabilization of implant-supported overdenture is associated with more patient satisfaction, chewing capability, and oral health-related quality of life. ...
Pengaruh ESG dan Ukuran Perusahaan terhadap Retention Ratio Industri Logam di BEI 2021-2022
Pengaruh ESG dan Ukuran Perusahaan terhadap Retention Ratio Industri Logam di BEI 2021-2022
Penelitian ini merupakan penelitian kuantitatif dengan metode deskriptif kuantitatif yang bertujuan untuk memberikan bukti  secara empiris pengaruh Environmental, Social And Govern...
Collaborative Design and Manufacturing of Prosthodontics Wire Clasp
Collaborative Design and Manufacturing of Prosthodontics Wire Clasp
The core idea behind the concurrent engineering is an integration of upstream and downstream activities of design/manufacturing in order to produce better products in a timely mann...
Multi-Modal Protein Representation Learning with CLASP
Multi-Modal Protein Representation Learning with CLASP
ABSTRACT Effectively integrating data modalities pertaining to proteins’ amino acid sequences, three-dimensional structures, and curated text-based descriptions of ...

Back to Top