Javascript must be enabled to continue!
CLASP RETENTION USING VARIABLE UNDERCUT DEPTHS
View through CrossRef
Retentive force may be increased in deeper undercuts. Three clasps were examined for this hypothesis in order to analyze the retentive force change properties for each clasp design with increasing undercut depth only. A total of 36 cobalt-chromium clasps, using half-round pattern and standard casting technique were fabricated. Three groups of clasps; Rest-Plate-Akers system, half-half, and Akers were engaged in 3 increasing undercut depths (0.25, 0.35, and 0.5 mm) on natural premolars. The test model was stone duplicate of plastic replica. Clasp retentive force was measured using universal testing machine. The results showed that the retentive forces for the tested undercuts (0.25, 0.35 and 0.5mm) were 8.59±1.89, 14.74±2.70 and 15.21±1.17 N for Akers; 3.06±0.88, 4.26±0.29, and 5.9±0.53 for half-half; and 0.9±0.15, 2.06±0.60, 2.3±0.50 N for Rest-Plat-Akers system respectively. Besides, the retentive force for each clasp design increased in a different way with each incremental augmentation of undercut depth. As a conclusion, changing the undercut depth altered the retentive force of the used clasp. Therefore, a clasp chosen for a definite undercut depth also can be used for deeper undercut on the same abutment when higher retentive force is required with respect to the other indication criteria.
Title: CLASP RETENTION USING VARIABLE UNDERCUT DEPTHS
Description:
Retentive force may be increased in deeper undercuts.
Three clasps were examined for this hypothesis in order to analyze the retentive force change properties for each clasp design with increasing undercut depth only.
A total of 36 cobalt-chromium clasps, using half-round pattern and standard casting technique were fabricated.
Three groups of clasps; Rest-Plate-Akers system, half-half, and Akers were engaged in 3 increasing undercut depths (0.
25, 0.
35, and 0.
5 mm) on natural premolars.
The test model was stone duplicate of plastic replica.
Clasp retentive force was measured using universal testing machine.
The results showed that the retentive forces for the tested undercuts (0.
25, 0.
35 and 0.
5mm) were 8.
59±1.
89, 14.
74±2.
70 and 15.
21±1.
17 N for Akers; 3.
06±0.
88, 4.
26±0.
29, and 5.
9±0.
53 for half-half; and 0.
9±0.
15, 2.
06±0.
60, 2.
3±0.
50 N for Rest-Plat-Akers system respectively.
Besides, the retentive force for each clasp design increased in a different way with each incremental augmentation of undercut depth.
As a conclusion, changing the undercut depth altered the retentive force of the used clasp.
Therefore, a clasp chosen for a definite undercut depth also can be used for deeper undercut on the same abutment when higher retentive force is required with respect to the other indication criteria.
Related Results
Maximum Dislodging Forces of Mandibular Implant‐Assisted Removable Partial Dentures: In Vitro Assessment
Maximum Dislodging Forces of Mandibular Implant‐Assisted Removable Partial Dentures: In Vitro Assessment
AbstractPurposeThe initial retention of implant‐assisted removable partial dentures (IARPDs) is unknown. The purpose of this in vitro study was to compare maximum dislodging forces...
EFFECT OF DESIGN CHANGING OF RING CLASP ON ITS RETENTIVE FORCE
EFFECT OF DESIGN CHANGING OF RING CLASP ON ITS RETENTIVE FORCE
Different designs of ring clasp were indicated in short or long span bounded saddle. However, few researches have been done to calculate their retentive absolute forces. The purpos...
Increased life expectancy of heart failure patients in a rural center by a multidisciplinary program
Increased life expectancy of heart failure patients in a rural center by a multidisciplinary program
Abstract
Funding Acknowledgements
Type of funding sources: None.
INTRODUCTION Patients with heart failure (HF)...
Pengaruh Kepemimpinan Kepala Sekolah, Lingkungan Kerja, dan Sarana Pembelajaran terhadap Kinerja Guru Melalui Motivasi Kerja
Pengaruh Kepemimpinan Kepala Sekolah, Lingkungan Kerja, dan Sarana Pembelajaran terhadap Kinerja Guru Melalui Motivasi Kerja
Penelitian ini mengkaji pengaruh kepemimpinan kepala sekolah, lingkungan sekolah, dan sarana pembelajaran terhadap kinerja guru SMAS Reformasi Plus, dengan motivasi guru sebagai va...
Stability of aligned maxillary anterior teeth after orthodontic treatment: amount of changes with different retention methods and without retention
Stability of aligned maxillary anterior teeth after orthodontic treatment: amount of changes with different retention methods and without retention
Well-aligned anterior teeth are the major reason for the patients seeking orthodontic treatment, and keeping teeth aligned and stable afterwards is a goal for the orthodontist and ...
Retention Evaluation of Implant-Supported Palateless Maxillary Overdentures Retained by PEEK Telescopic Attachment
Retention Evaluation of Implant-Supported Palateless Maxillary Overdentures Retained by PEEK Telescopic Attachment
Background: Retention and stabilization of implant-supported overdenture is associated with more patient satisfaction, chewing capability, and oral health-related quality of life. ...
Pengaruh ESG dan Ukuran Perusahaan terhadap Retention Ratio Industri Logam di BEI 2021-2022
Pengaruh ESG dan Ukuran Perusahaan terhadap Retention Ratio Industri Logam di BEI 2021-2022
Penelitian ini merupakan penelitian kuantitatif dengan metode deskriptif kuantitatif yang bertujuan untuk memberikan bukti secara empiris pengaruh Environmental, Social And Govern...
What influences communication about retention in randomised trials: a multi-trial, theory-based analysis exploring trial staff perspectives
What influences communication about retention in randomised trials: a multi-trial, theory-based analysis exploring trial staff perspectives
Abstract
Background
Retention (participants completing a trial) is a persistent, and often under-studied, challenge within clinical trials. Research...

