Javascript must be enabled to continue!
Comparison between Acetal Resin and Cobalt-Chromium Removable Partial Denture Clasp Retention: An in vitro Study
View through CrossRef
ABSTRACT
Statement of problem
The retention qualities of acetal resin clasps are questionable.
Purpose
To asses the initial retention and after cycling for 1,200 cycles of acetal resin clasps as compared to cobalt-chromium clasps.
Materials and methods
Extracted maxillary first premolars and molars were collected. Each tooth was embedded in acrylic block up to the cementoenamel junction. On each block, partial denture model consisted of Akers clasp, minor connector, cobalt-chromium horizontal plate representing the denture base, and a vertical arm on the horizontal plate was constructed. Models were divided into four groups (five each). Group I had acetal resin clasps on premolars. Group II had cobalt-chromium clasps on premolars. Group III had acetal resin clasps on molars. Group IV had cobalt-chromium clasps on molars. Akers clasps were designed to utilize 0.01 inch undercut. Each model was connected to the universal testing machine through the vertical arm. The model was placed in artificial saliva and a tensile load was applied to measure the initial retention. Then retention was measured after cycling for 200, 400, 600, 800, 1,000 and 1,200 cycles. One-way analysis of variance followed by Duncan's multiple range test was used to test the effect of groups and cycling on tensile load required for clasp dislodgment.
Results
Groups I and III showed no change in retention on cycling up to 1,200 cycles. Group I showed significantly higher retention than group III. Groups II and IV showed significant reduction in retention upon cycling more than 800 cycles. In spite of this reduction in retention, it is still higher than that in groups I and III.
Conclusion
Cobalt-chromium clasps showed higher retention than acetal resin clasps despite the deformation encountered in the former. Acetal resin clasps showed more retention qualities on premolar teeth than that on molar teeth.
Clinical implications
Acetal resin clasps can be used to retain Kennedy's class III partial denture. However, when used on molar teeth, it is recommended to increase the thickness of the retentive clasp arm or to use a deeper undercut.
How to cite this article
Mohamed T, Baraka OA, Badawy MM. Comparison between Acetal Resin and Cobalt-Chromium Removable Partial Denture Clasp Retention: An in vitro Study. Int J Prosthodont Restor Dent 2013;3(2):50-56.
Jaypee Brothers Medical Publishing
Title: Comparison between Acetal Resin and Cobalt-Chromium Removable Partial Denture Clasp Retention: An in vitro Study
Description:
ABSTRACT
Statement of problem
The retention qualities of acetal resin clasps are questionable.
Purpose
To asses the initial retention and after cycling for 1,200 cycles of acetal resin clasps as compared to cobalt-chromium clasps.
Materials and methods
Extracted maxillary first premolars and molars were collected.
Each tooth was embedded in acrylic block up to the cementoenamel junction.
On each block, partial denture model consisted of Akers clasp, minor connector, cobalt-chromium horizontal plate representing the denture base, and a vertical arm on the horizontal plate was constructed.
Models were divided into four groups (five each).
Group I had acetal resin clasps on premolars.
Group II had cobalt-chromium clasps on premolars.
Group III had acetal resin clasps on molars.
Group IV had cobalt-chromium clasps on molars.
Akers clasps were designed to utilize 0.
01 inch undercut.
Each model was connected to the universal testing machine through the vertical arm.
The model was placed in artificial saliva and a tensile load was applied to measure the initial retention.
Then retention was measured after cycling for 200, 400, 600, 800, 1,000 and 1,200 cycles.
One-way analysis of variance followed by Duncan's multiple range test was used to test the effect of groups and cycling on tensile load required for clasp dislodgment.
Results
Groups I and III showed no change in retention on cycling up to 1,200 cycles.
Group I showed significantly higher retention than group III.
Groups II and IV showed significant reduction in retention upon cycling more than 800 cycles.
In spite of this reduction in retention, it is still higher than that in groups I and III.
Conclusion
Cobalt-chromium clasps showed higher retention than acetal resin clasps despite the deformation encountered in the former.
Acetal resin clasps showed more retention qualities on premolar teeth than that on molar teeth.
Clinical implications
Acetal resin clasps can be used to retain Kennedy's class III partial denture.
However, when used on molar teeth, it is recommended to increase the thickness of the retentive clasp arm or to use a deeper undercut.
How to cite this article
Mohamed T, Baraka OA, Badawy MM.
Comparison between Acetal Resin and Cobalt-Chromium Removable Partial Denture Clasp Retention: An in vitro Study.
Int J Prosthodont Restor Dent 2013;3(2):50-56.
Related Results
The effect of immersion cleansers on gloss, colour and sorption of acetal denture base material
The effect of immersion cleansers on gloss, colour and sorption of acetal denture base material
doi: 10.1111/j.1741‐2358.2012.00657.x
The effect of immersion cleansers on gloss, colour and sorption of acetal denture base material
Objective: To study the effect of peroxide a...
Denture Stomatitis and Its Associations Among Older Adults in the United Arab Emirates
Denture Stomatitis and Its Associations Among Older Adults in the United Arab Emirates
ABSTRACT
Background
Denture stomatitis is a common oral mucosal lesion among older adults wearing removable prostheses. I...
Tensile Bond Strength between Different Denture Base Materials and Soft Denture Liners
Tensile Bond Strength between Different Denture Base Materials and Soft Denture Liners
(1) Background: Various materials are available for CAD-CAM denture base fabrication, for both additive and subtractive manufacturing. However, little has been reported on bond str...
Maximum Dislodging Forces of Mandibular Implant‐Assisted Removable Partial Dentures: In Vitro Assessment
Maximum Dislodging Forces of Mandibular Implant‐Assisted Removable Partial Dentures: In Vitro Assessment
AbstractPurposeThe initial retention of implant‐assisted removable partial dentures (IARPDs) is unknown. The purpose of this in vitro study was to compare maximum dislodging forces...
Denture microbiome shift and changes of salivary inflammatory markers following insertion of 3D printed removable partial PMMA denture: a pilot study
Denture microbiome shift and changes of salivary inflammatory markers following insertion of 3D printed removable partial PMMA denture: a pilot study
Abstract
Background
The aim of this study was to investigate the microbiome shift of denture biofilm formation, the incidence of Candida and changes...
Contemporary methods and mobile denture cleansers and theirs significance for older population
Contemporary methods and mobile denture cleansers and theirs significance for older population
Introduction. A dramatic increase in the number of people living in their
seventies, eighties and nineties is associated with a loss of teeth and the
use of mobile dentures. ...
Clinical Evaluation of Patient Satisfaction with Aesthetics, Retention, Function, and Comfort of Removable Complete and Partial Acrylic Dentures
Clinical Evaluation of Patient Satisfaction with Aesthetics, Retention, Function, and Comfort of Removable Complete and Partial Acrylic Dentures
Objectives: The quality of removable dentures (acrylic partial and complete) significantly affects patients’ quality of life, encompassing aspects such as aesthetics, function and ...
THE STUDY OF BIOCHEMICAL INDIXES OF ORAL FLUID IN ORTHODONTIC TREATMENT
THE STUDY OF BIOCHEMICAL INDIXES OF ORAL FLUID IN ORTHODONTIC TREATMENT
The work is devoted to the study of the reactivity of the biochemical composition of saliva in children with SCI, which was used for the treatment of non-removable and removable OA...