Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Tensile Bond Strength between Different Denture Base Materials and Soft Denture Liners

View through CrossRef
(1) Background: Various materials are available for CAD-CAM denture base fabrication, for both additive and subtractive manufacturing. However, little has been reported on bond strength to soft denture liners. Therefore, the aim of this study was to investigate tensile bond strength, comparing between different denture base materials and soft denture liners. (2) Methods: Seven different materials were used for denture base fabrication: one heat-polymerized polymethyl methacrylate, three materials for subtractive manufacturing, two materials for additive manufacturing and one polyamide. Two materials were used for soft denture lining: one silicone-based and one acrylate-based. The study was conducted according to the specification ISO No. 10139-2:2016, and the type of failure was determined. The Kruskal–Wallis test with Dunn’s post hoc test was used to analyse the values of tensile bond strength, and Fisher’s exact test was used to analyse the type of failure. p Values < 0.05 were considered statistically significant. (3) Results: The tensile bond strength values were not statistically significantly different combining all the materials used for denture base fabrication with the acrylate-based soft denture liner (p > 0.05), and the average values ranged between 0.19 and 0.25 Mpa. The tensile bond strength values of the different denture base materials and silicone-based denture liner were statistically significantly different (p < 0.05), and the average values ranged between 1.49 and 3.07 Mpa. The type of failure was predominantly adhesive between polyamide and both additive-manufactured denture base materials in combination with the acrylate-based soft liner (p < 0.05). (4) Conclusions: The use of digital technologies in denture base fabrication can have an influence on different tensile bond strength values for soft denture liners, with different types of failure when compared with heat-cured PMMA. Similar tensile bond strength values were found between the acrylate-based soft denture liner and denture base materials. Significant differences in tensile bond strength values were found between the silicone-based soft denture liner and denture base materials, where the additive-manufactured and polyamide denture base materials showed lower values than heat-cured PMMA and subtractive-manufactured denture base materials.
Title: Tensile Bond Strength between Different Denture Base Materials and Soft Denture Liners
Description:
(1) Background: Various materials are available for CAD-CAM denture base fabrication, for both additive and subtractive manufacturing.
However, little has been reported on bond strength to soft denture liners.
Therefore, the aim of this study was to investigate tensile bond strength, comparing between different denture base materials and soft denture liners.
(2) Methods: Seven different materials were used for denture base fabrication: one heat-polymerized polymethyl methacrylate, three materials for subtractive manufacturing, two materials for additive manufacturing and one polyamide.
Two materials were used for soft denture lining: one silicone-based and one acrylate-based.
The study was conducted according to the specification ISO No.
10139-2:2016, and the type of failure was determined.
The Kruskal–Wallis test with Dunn’s post hoc test was used to analyse the values of tensile bond strength, and Fisher’s exact test was used to analyse the type of failure.
p Values < 0.
05 were considered statistically significant.
(3) Results: The tensile bond strength values were not statistically significantly different combining all the materials used for denture base fabrication with the acrylate-based soft denture liner (p > 0.
05), and the average values ranged between 0.
19 and 0.
25 Mpa.
The tensile bond strength values of the different denture base materials and silicone-based denture liner were statistically significantly different (p < 0.
05), and the average values ranged between 1.
49 and 3.
07 Mpa.
The type of failure was predominantly adhesive between polyamide and both additive-manufactured denture base materials in combination with the acrylate-based soft liner (p < 0.
05).
(4) Conclusions: The use of digital technologies in denture base fabrication can have an influence on different tensile bond strength values for soft denture liners, with different types of failure when compared with heat-cured PMMA.
Similar tensile bond strength values were found between the acrylate-based soft denture liner and denture base materials.
Significant differences in tensile bond strength values were found between the silicone-based soft denture liner and denture base materials, where the additive-manufactured and polyamide denture base materials showed lower values than heat-cured PMMA and subtractive-manufactured denture base materials.

Related Results

An In vitro Evaluation of Tensile Bond Strength of Soft Liners Bonded to Different Denture Base Resins
An In vitro Evaluation of Tensile Bond Strength of Soft Liners Bonded to Different Denture Base Resins
Background: Clinically, adhesion failure is the most critical problem because of the failure of the optimal bond between denture base and the soft liner. ...
Effect of different surface treatments on tensile bond strength of acrylic denture teeth to CAD/CAM denture base
Effect of different surface treatments on tensile bond strength of acrylic denture teeth to CAD/CAM denture base
Purpose This study evaluated the effect of different surface treatments on tensile bond strength of acrylic denture teeth to prepolymerized computer-aided design/comput...
Peel Bond Strength of Soft Liner Using Dental CAD/CAM and Conventional Acrylic Denture Base Materials Treated by Sandblast Technique
Peel Bond Strength of Soft Liner Using Dental CAD/CAM and Conventional Acrylic Denture Base Materials Treated by Sandblast Technique
Background: One of the most serious problems with silicone soft liners is that they cannot cling to the acrylic denture foundation. The peel test is an appropriate method for asses...
Contemporary methods and mobile denture cleansers and theirs significance for older population
Contemporary methods and mobile denture cleansers and theirs significance for older population
Introduction. A dramatic increase in the number of people living in their seventies, eighties and nineties is associated with a loss of teeth and the use of mobile dentures. ...
Effect of Ozone and Two Common Denture Cleaners on Tensile Bond Strength and Surface Hardness of a Silicone Soft Liner
Effect of Ozone and Two Common Denture Cleaners on Tensile Bond Strength and Surface Hardness of a Silicone Soft Liner
Objectives: To evaluate the effect of ozone and two common denture cleansers on the surface hardness and bond strength of a silicone-based soft liner to acrylic denture base materi...
Antifungal effects of eugenol on Candida albicans adherence to denture polymers
Antifungal effects of eugenol on Candida albicans adherence to denture polymers
Background The study’s objective is to assess the adherence of C. albicans in different types of denture polymers and the effectiveness of eugenol and commercialized...
Microflora in denture stomatitis - A review
Microflora in denture stomatitis - A review
Denture stomatitis is an inflammation that typically occurs in individuals that have a complete or partial denture. Denture stomatitis is commonly defined as persistent inflammator...
In Vitro Evaluation of the Fracture Strength among Three Different Denture Base Materials
In Vitro Evaluation of the Fracture Strength among Three Different Denture Base Materials
Failure in the form of denture fracture is commonly encountered by both removable prosthodontics wearers and dentists, it is mainly attributed to material properties, technical fea...

Back to Top