Javascript must be enabled to continue!
Maximum Dislodging Forces of Mandibular Implant‐Assisted Removable Partial Dentures: In Vitro Assessment
View through CrossRef
AbstractPurposeThe initial retention of implant‐assisted removable partial dentures (IARPDs) is unknown. The purpose of this in vitro study was to compare maximum dislodging forces of distal extension mandibular IARPD with two different attachments and three clasp designs.Materials and MethodsA simulated class I partially edentulous mandible was prepared with two screw‐type 3.75×12 mm implants in the first molar regions and 2 metal‐ceramic crowns on distal abutments. Fifteen bilateral distal extension frameworks were conventionally fabricated in three clasp designs (suprabulge, infrabulge, no clasp). Locator attachments were connected to the 15 denture bases with autopolymerized resin. Each specimen was subject to four types of retention pulls (main, anterior, posterior, unilateral pull) five times with a universal testing machine. Locator attachments were replaced with O‐ring attachments, and the same procedure was performed. Therefore, the study groups included: IRPD with Locator attachment and suprabulge clasp (group 1), IRPD with Locator attachment and infrabulge clasp (group 2), IRPD with Locator attachment and no clasp (group 3), IRPD with O‐ring attachment and suprabulge clasp (group 4), IRPD with O‐ring attachment and infrabulge clasp (group 5), IRPD with O‐ring attachment and no clasp (group 6). Data were analyzed using one‐way ANOVA, two‐way ANOVA, and Tukey tests.ResultsThe highest mean value was 22.99 lb for prostheses with a Locator attachment and suprabulge clasp. The lowest retentive values were recorded for IARPDs with O‐ring attachments.ConclusionThe results of this in vitro study suggest that the precise selection of attachments with or without clasp assemblies may affect the clinical success of mandibular IARPDs.
Title: Maximum Dislodging Forces of Mandibular Implant‐Assisted Removable Partial Dentures: In Vitro Assessment
Description:
AbstractPurposeThe initial retention of implant‐assisted removable partial dentures (IARPDs) is unknown.
The purpose of this in vitro study was to compare maximum dislodging forces of distal extension mandibular IARPD with two different attachments and three clasp designs.
Materials and MethodsA simulated class I partially edentulous mandible was prepared with two screw‐type 3.
75×12 mm implants in the first molar regions and 2 metal‐ceramic crowns on distal abutments.
Fifteen bilateral distal extension frameworks were conventionally fabricated in three clasp designs (suprabulge, infrabulge, no clasp).
Locator attachments were connected to the 15 denture bases with autopolymerized resin.
Each specimen was subject to four types of retention pulls (main, anterior, posterior, unilateral pull) five times with a universal testing machine.
Locator attachments were replaced with O‐ring attachments, and the same procedure was performed.
Therefore, the study groups included: IRPD with Locator attachment and suprabulge clasp (group 1), IRPD with Locator attachment and infrabulge clasp (group 2), IRPD with Locator attachment and no clasp (group 3), IRPD with O‐ring attachment and suprabulge clasp (group 4), IRPD with O‐ring attachment and infrabulge clasp (group 5), IRPD with O‐ring attachment and no clasp (group 6).
Data were analyzed using one‐way ANOVA, two‐way ANOVA, and Tukey tests.
ResultsThe highest mean value was 22.
99 lb for prostheses with a Locator attachment and suprabulge clasp.
The lowest retentive values were recorded for IARPDs with O‐ring attachments.
ConclusionThe results of this in vitro study suggest that the precise selection of attachments with or without clasp assemblies may affect the clinical success of mandibular IARPDs.
Related Results
Morphologic alterations in the mucosa of the denture site in patients with full removable dentures from acrylic plastics
Morphologic alterations in the mucosa of the denture site in patients with full removable dentures from acrylic plastics
Relevance. Currently, many new agents have appeared on the market for users of removable dentures to improve adhesion, i.e. fixation and stabilization of dentures. It is important ...
SURVEY OF A FUNCTIONAL STATE OF MASSETER MUSCLES IN EDENTELOUS PATIENTS BASED ON THE DATA OF SURFACE ELECTROMYOGYOPHY STUDIES
SURVEY OF A FUNCTIONAL STATE OF MASSETER MUSCLES IN EDENTELOUS PATIENTS BASED ON THE DATA OF SURFACE ELECTROMYOGYOPHY STUDIES
The difficulty of prosthetics and rehabilitation of patients with complete loss of teeth is associated with a burdened psychological and anatomical status. The main reasons for tee...
Restorative dentistry 3: replacing teeth
Restorative dentistry 3: replacing teeth
Contents. Treatment planning for patients with missing teeth. Bridges. Bridges—design. Bridges—practical stages. Bridge failures. Resin-bonded bridges. Removable partial dentures—p...
Behaviors, hygiene habits, and sources of care among removable complete and partial dentures wearers: A multicenter cross‐sectional study
Behaviors, hygiene habits, and sources of care among removable complete and partial dentures wearers: A multicenter cross‐sectional study
AbstractObjectivesThere is a lack of data regarding the hygiene practices and sources of care among individuals in Yemen who wear removable complete and partial dentures. The purpo...
XEROSTOMIA AND ITS EFFECTS ON THE REMOVABLE DENTURES PROPERTIES AND ORAL FUNCTIONS IN ELDERLY PATIENTS: A CROSS-SECTIONAL STUDY
XEROSTOMIA AND ITS EFFECTS ON THE REMOVABLE DENTURES PROPERTIES AND ORAL FUNCTIONS IN ELDERLY PATIENTS: A CROSS-SECTIONAL STUDY
Objective:
To determine the frequency of xerostomia in elderly patients and its effects on removable dentures retention, stability, support and its effects on the functions o...
Mandibular implant‐supported removable partial denture with distal extension: a systematic review
Mandibular implant‐supported removable partial denture with distal extension: a systematic review
Summary The aim of this article is to investigate patient satisfaction, survival rate of implants, and prosthetic complications or maintenance for rehabilitation with removable pa...
Clinical Evaluation of Patient Satisfaction with Aesthetics, Retention, Function, and Comfort of Removable Complete and Partial Acrylic Dentures
Clinical Evaluation of Patient Satisfaction with Aesthetics, Retention, Function, and Comfort of Removable Complete and Partial Acrylic Dentures
Objectives: The quality of removable dentures (acrylic partial and complete) significantly affects patients’ quality of life, encompassing aspects such as aesthetics, function and ...
Flexible Denture: A Hope for Partial Edentulous Patient- A Case Report
Flexible Denture: A Hope for Partial Edentulous Patient- A Case Report
The various treatment options for the aesthetic and functional rehabilitation of partially edentulous patients are conventional fixed partial dentures, implant supported fixed part...

