Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Evaluation of a Direct Ion Storage dosimeter efficiency to measure dose during interventional cardiology procedures

View through CrossRef
Intracardiac electrophysiological invasive procedures guided by fluoroscopy aim to study the cardiac depolarization process. Depending on the complexity of the clinical case, both patients and professionals are subjected to radiation for a prolonged period. This work evaluated if a direct ions storage (DIS) dosimeter could measure occupational doses in different regions of the physician's body during these procedures. Doses were monitored close to the left eye (LE), right eye (RE), extremity (left ankle), and thorax, as well as the environmental dose, positioning the dosimeter in the center of the equipment gantry. These doses were evaluated in 31 procedures using 01 DIS dosimeter in each region. The Mann-Whitney U test demonstrated that the values obtained in the different regions represent different samples, while the Spearman test demonstrated that there is no evidence that there is a correlation between the data recorded in the different regions. DIS was effective in recording the doses in the LE region and the doses of dispersed radiation (Arc), with the values obtained: (30 quartile / maximum): LE (0.07 / 0.20 mSv); Arc (0.38 / 1.53 mSv). It was not possible to compare occupational doses between different regions of the physician's body, limiting its use as a complementary monitor in the control of occupational doses.
Title: Evaluation of a Direct Ion Storage dosimeter efficiency to measure dose during interventional cardiology procedures
Description:
Intracardiac electrophysiological invasive procedures guided by fluoroscopy aim to study the cardiac depolarization process.
Depending on the complexity of the clinical case, both patients and professionals are subjected to radiation for a prolonged period.
This work evaluated if a direct ions storage (DIS) dosimeter could measure occupational doses in different regions of the physician's body during these procedures.
Doses were monitored close to the left eye (LE), right eye (RE), extremity (left ankle), and thorax, as well as the environmental dose, positioning the dosimeter in the center of the equipment gantry.
These doses were evaluated in 31 procedures using 01 DIS dosimeter in each region.
The Mann-Whitney U test demonstrated that the values obtained in the different regions represent different samples, while the Spearman test demonstrated that there is no evidence that there is a correlation between the data recorded in the different regions.
DIS was effective in recording the doses in the LE region and the doses of dispersed radiation (Arc), with the values obtained: (30 quartile / maximum): LE (0.
07 / 0.
20 mSv); Arc (0.
38 / 1.
53 mSv).
It was not possible to compare occupational doses between different regions of the physician's body, limiting its use as a complementary monitor in the control of occupational doses.

Related Results

Development of end-to-end test phantom for stereotactic radiosurgery using alanine dosimeter
Development of end-to-end test phantom for stereotactic radiosurgery using alanine dosimeter
Alanine dosimeters are generally used in high-dose dosimetry, while accurate and precise dose delivery verification procedures are important in stereotactic radiosurgery (SRS). Hen...
Investigation of alanine dosimeter for output measurement in radiotherapy: Results from multicenter in Thailand
Investigation of alanine dosimeter for output measurement in radiotherapy: Results from multicenter in Thailand
Background: Alanine dosimeters are generally used in high-dose industrial applications (kGy). Later, research into employing alanine as a dosimeter in radiotherapy (1-20 Gy) has in...
Computed Dosimeter Dose Index on a 16-Slice Computed Tomography Scanner
Computed Dosimeter Dose Index on a 16-Slice Computed Tomography Scanner
A computed tomography dose index can be used to quantify the radiation dose received during a CT scan and it is an indicator of the radiation dose to the polymetaylenmetaAcrylate (...
Surface and build-up region dose measurement in head and neck region using radio - photoluminescent glass dosimeter
Surface and build-up region dose measurement in head and neck region using radio - photoluminescent glass dosimeter
The use of commercially available radio-photoluminescent glass dosimeter (RPLGD) for radiation measurement has increased in recent years. It has been shown to have superior dosimet...
Social media in interventional radiology
Social media in interventional radiology
AbstractIntroductionSocial media provides opportunities for Interventional Radiologists to share research, communicate with colleagues, provide health information and advertise the...
Oxford Textbook of Interventional Cardiology
Oxford Textbook of Interventional Cardiology
The Oxford Textbook of Interventional Cardiology is the definitive text, spanning the whole spectrum of interventional cardiology procedures, including management of patients with ...