Javascript must be enabled to continue!
Surface and build-up region dose measurement in head and neck region using radio - photoluminescent glass dosimeter
View through CrossRef
The use of commercially available radio-photoluminescent glass dosimeter (RPLGD) for radiation measurement has increased in recent years. It has been shown to have superior dosimetric characteristics as compared to other dosimeters. The purpose of this research is to evaluate the suitability of the GD-302M glass dosimeter for surface and build-up region dose measurement in head and neck region. The glass dosimeter was analyzed for its dosimetric properties in photon beam. Then, the study was performed for surface and build-up region dose comparison between EBT3 film and RPLGD in solid water phantom at 0, 2, 3, 5, 10 and 15mm depths of 6 MV beams. In addition, 3D-CRT and VMAT plans for nasopharyngeal carcinoma were transferred to a Rando phantom for verification of build-up region dose at 5 and 10mm depths. The results found that uniformity obtained in this study was within 1.1%. The dose-response was linear with R2 of 0.999. Dose rate, reproducibility, angular and energy dependence were found to be within 3.0%. Moreover, fading effect was less than 3% over 4 weeks. The dose in homogeneous solid water phantom showed good agreement between RPLGD and EBT3 film in build-up region. However, RPLGD showed over response of signal at the surface due to the thickness of its holder. The verification in Rando phantom illustrated that build-up region doses were higher in TPS calculation compared to RPLGD measurements both in 3DCRT and VMAT. The average dose differences between measurements and calculations were -0.18±1.21% and 2.40±1.49% at 5 mm and 10 mm depth for 3D-CRT, and 4.74±1.12% and 3.44±4.41% at 5 mm and 10 mm depth for VMAT, respectively. In conclusion, RPLGD is less suitable for surface dose measurement but has good potential to be used as an in-vivo dosimeter in build-up dose measurements.
Title: Surface and build-up region dose measurement in head and neck region using radio - photoluminescent glass dosimeter
Description:
The use of commercially available radio-photoluminescent glass dosimeter (RPLGD) for radiation measurement has increased in recent years.
It has been shown to have superior dosimetric characteristics as compared to other dosimeters.
The purpose of this research is to evaluate the suitability of the GD-302M glass dosimeter for surface and build-up region dose measurement in head and neck region.
The glass dosimeter was analyzed for its dosimetric properties in photon beam.
Then, the study was performed for surface and build-up region dose comparison between EBT3 film and RPLGD in solid water phantom at 0, 2, 3, 5, 10 and 15mm depths of 6 MV beams.
In addition, 3D-CRT and VMAT plans for nasopharyngeal carcinoma were transferred to a Rando phantom for verification of build-up region dose at 5 and 10mm depths.
The results found that uniformity obtained in this study was within 1.
1%.
The dose-response was linear with R2 of 0.
999.
Dose rate, reproducibility, angular and energy dependence were found to be within 3.
0%.
Moreover, fading effect was less than 3% over 4 weeks.
The dose in homogeneous solid water phantom showed good agreement between RPLGD and EBT3 film in build-up region.
However, RPLGD showed over response of signal at the surface due to the thickness of its holder.
The verification in Rando phantom illustrated that build-up region doses were higher in TPS calculation compared to RPLGD measurements both in 3DCRT and VMAT.
The average dose differences between measurements and calculations were -0.
18±1.
21% and 2.
40±1.
49% at 5 mm and 10 mm depth for 3D-CRT, and 4.
74±1.
12% and 3.
44±4.
41% at 5 mm and 10 mm depth for VMAT, respectively.
In conclusion, RPLGD is less suitable for surface dose measurement but has good potential to be used as an in-vivo dosimeter in build-up dose measurements.
Related Results
Unveiling the third dimension of glass
Unveiling the third dimension of glass
Glass as a material has always fascinated architects. Its inherent transparency has given us the ability to create diaphanous barriers between the interior and the exterior that al...
Development of end-to-end test phantom for stereotactic radiosurgery using alanine dosimeter
Development of end-to-end test phantom for stereotactic radiosurgery using alanine dosimeter
Alanine dosimeters are generally used in high-dose dosimetry, while accurate and precise dose delivery verification procedures are important in stereotactic radiosurgery (SRS). Hen...
Investigation of alanine dosimeter for output measurement in radiotherapy: Results from multicenter in Thailand
Investigation of alanine dosimeter for output measurement in radiotherapy: Results from multicenter in Thailand
Background: Alanine dosimeters are generally used in high-dose industrial applications (kGy). Later, research into employing alanine as a dosimeter in radiotherapy (1-20 Gy) has in...
Magnetohydrodynamics enhanced radio blackout mitigation system for spacecraft during planetary entries
Magnetohydrodynamics enhanced radio blackout mitigation system for spacecraft during planetary entries
(English) Spacecraft entering planetary atmospheres are enveloped by a plasma layer with high levels of ionization, caused by the extreme temperatures in the shock layer. The charg...
Pengelolaan Platform Digital Penyiaran pada Urban Radio 106.3 FM
Pengelolaan Platform Digital Penyiaran pada Urban Radio 106.3 FM
Abstract. Urban Radio 106.3 FM is one of the modern radio stations broadcasting on the frequency 106.3 FM in the city of Bandung. This research is focused on the "Management of Dig...
Computed Dosimeter Dose Index on a 16-Slice Computed Tomography Scanner
Computed Dosimeter Dose Index on a 16-Slice Computed Tomography Scanner
A computed tomography dose index can be used to quantify the radiation dose received during a CT scan and it is an indicator of the radiation dose to the polymetaylenmetaAcrylate (...
Strategi Dakwah Program Radio SAS FM Surabaya
Strategi Dakwah Program Radio SAS FM Surabaya
Abstrak: Ada tiga persoalan yang dikaji dalam penelitian ini, yakni : (1) Bagaimana konsep awal terbentuknya radio SAS FM Surabaya, (2) Bagaimana strategi dakwah pada program “...
Radio Emission of Nearby Early-type Galaxies in the Low and Very Low Radio Luminosity Range
Radio Emission of Nearby Early-type Galaxies in the Low and Very Low Radio Luminosity Range
Abstract
We analyze radio continuum emission of early-type galaxies with dynamical measurements of central supermassive black hole (SMBH) masses and well-characteriz...