Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Masking Ability of Monolithic and Layered Zirconia Crowns on Discolored Substrates

View through CrossRef
There is scarce information on the colorimetric behavior of monolithic and layered zirconia crowns in combination with various abutment colors. This study evaluated the masking ability on discolored substrates of monolithic and layered zirconia crowns. Anterior crowns were fabricated using 3Y-TZP zirconia and layering ceramic and divided into three groups: monolithic (ML), bi-layer (BL), and tri-layer (TL). The crowns were placed over eleven substrates (ND1-ND9, zirconia, metal), and CIE L*, a*, b*, C*, and h° color coordinates were measured in the cervical, middle, and incisal areas with a spectrophotometer. Masking ability was calculated using the color difference formula, and values were interpreted according to the perceptibility and acceptability thresholds. Data were analyzed statistically (α = 0.001). The L* coordinate was not significantly different between BL and TL crowns, regardless of the measurement area or substrate (p ≥ 0.001). In the middle area, the L* coordinate of the ML group was statistically different from the BL and TL groups only for zirconia and metal substrates, while in the incisal area, only for ND7 and metal substrates. The a* coordinate was significantly different between the ML and layered crowns for all measurement areas and substrates (except zirconia). The b* and C* coordinates differed significantly between the groups only in the cervical area (p < 0.001). The ML crown had better masking ability than the BL and TL crowns. However, the color differences for ML crowns were below the acceptability threshold for ND2, ND3, and ND7 substrates in the cervical and middle areas and below perceptibility threshold only for the incisal area. The lowest masking ability of the crowns was found for ND9 and metal substrates in all measurement areas.
Title: Masking Ability of Monolithic and Layered Zirconia Crowns on Discolored Substrates
Description:
There is scarce information on the colorimetric behavior of monolithic and layered zirconia crowns in combination with various abutment colors.
This study evaluated the masking ability on discolored substrates of monolithic and layered zirconia crowns.
Anterior crowns were fabricated using 3Y-TZP zirconia and layering ceramic and divided into three groups: monolithic (ML), bi-layer (BL), and tri-layer (TL).
The crowns were placed over eleven substrates (ND1-ND9, zirconia, metal), and CIE L*, a*, b*, C*, and h° color coordinates were measured in the cervical, middle, and incisal areas with a spectrophotometer.
Masking ability was calculated using the color difference formula, and values were interpreted according to the perceptibility and acceptability thresholds.
Data were analyzed statistically (α = 0.
001).
The L* coordinate was not significantly different between BL and TL crowns, regardless of the measurement area or substrate (p ≥ 0.
001).
In the middle area, the L* coordinate of the ML group was statistically different from the BL and TL groups only for zirconia and metal substrates, while in the incisal area, only for ND7 and metal substrates.
The a* coordinate was significantly different between the ML and layered crowns for all measurement areas and substrates (except zirconia).
The b* and C* coordinates differed significantly between the groups only in the cervical area (p < 0.
001).
The ML crown had better masking ability than the BL and TL crowns.
However, the color differences for ML crowns were below the acceptability threshold for ND2, ND3, and ND7 substrates in the cervical and middle areas and below perceptibility threshold only for the incisal area.
The lowest masking ability of the crowns was found for ND9 and metal substrates in all measurement areas.

Related Results

Optical properties of monolithic zirconia crowns: In vitro and In vivo evaluation
Optical properties of monolithic zirconia crowns: In vitro and In vivo evaluation
Background/Aim: The aim of this study was to compare the monolithic and layered zirconia crowns by their optical property of translucency, using in vitro and in vivo evaluation met...
Effect of Milling Protocols on Trueness and Precision of Ceramic Crowns
Effect of Milling Protocols on Trueness and Precision of Ceramic Crowns
AbstractPurposeTo investigate the effect of different milling protocols for different ceramic materials on the trueness and precision of milled ceramic crowns.Materials and Methods...
The Performance of PEKK vs Zirconia Abutments for Screw-Retained Crowns in Two-Piece Zirconia Implants: An in vitro Study
The Performance of PEKK vs Zirconia Abutments for Screw-Retained Crowns in Two-Piece Zirconia Implants: An in vitro Study
This study aimed to compare the in vitro performance of anterior and posterior crowns with screw-retained polyetherketoneketone (PEKK) or zirconia abutments on two-piece zirconia i...
Comparative evaluation of stress generation in primary teeth restored with zirconia and BioFlx crowns: A finite element analysis
Comparative evaluation of stress generation in primary teeth restored with zirconia and BioFlx crowns: A finite element analysis
Background: Maintaining the functional integrity of primary teeth is important, as these teeth are integral in vital functions such as mastication, speech development, and space ma...
Assessing the Longevity of Zirconia-Based Crowns in Bruxism Patients
Assessing the Longevity of Zirconia-Based Crowns in Bruxism Patients
ABSTRACT Background: Bruxism is a parafunctional habit that often leads to excessive wear and tear of dental restoration...
Fit, Precision, and Trueness of 3D-Printed Zirconia Crowns Compared to Milled Counterparts
Fit, Precision, and Trueness of 3D-Printed Zirconia Crowns Compared to Milled Counterparts
Precise fit of a crown and accurate reproduction of the digital design are paramount for successful treatment outcomes and preservation of clinician and technician time. The study ...
Influence of Margin Designs on Crack Initiation of High Translucency Monolithic Zirconia Crowns
Influence of Margin Designs on Crack Initiation of High Translucency Monolithic Zirconia Crowns
AbstractPurposeZirconia crowns often crack at the margin. This study determined the loads and the times at which cracks are initiated in high‐translucency monolithic zirconia crown...

Back to Top