Javascript must be enabled to continue!
Optical properties of monolithic zirconia crowns: In vitro and In vivo evaluation
View through CrossRef
Background/Aim: The aim of this study was to compare the monolithic and layered zirconia crowns by their optical property of translucency, using in vitro and in vivo evaluation methods. Material and Methods: One upper incisor and one canine were prepared to receive 6 monolithic Lava Plus HT and 6 layered Lava crowns using the CAD/CAM technology. The translucency in the vitro evaluation, was determined using a digital photoradiometer to measure the light reflected by the crowns in two different conditions, natural and metal plated abutment tooth. A provisional complete prosthesis of an edentulous patient, with the abutment teeth mounted in their anatomical position, was used for the in vivo evaluation. The crowns were randomly placed and evaluated by two independent operators in the oral cavity conditions. Results: In vitro results showed that monolithic crowns were not significantly less translucent than layered ones in both incisor (p=0.098) and canine (p=0.340): contrast ratio 0.978 vs. 0.956 and 0.941 vs. 0.929, respectively (Student -t test; a=0.05). In vivo evaluation results showed that the difference in the luminance was not statistically significant between Lava Plus HT and layered Lava crowns according to Mann Whitney Test, p=0.089 (a=0.01). Conclusions: The difference in translucency between monolithic and layered zirconia crowns was not statistically significant both in vitro and in vivo evaluation. Monolithic zirconia had a good masking ability of the abutment tooth.
Centre for Evaluation in Education and Science (CEON/CEES)
Title: Optical properties of monolithic zirconia crowns: In vitro and In vivo evaluation
Description:
Background/Aim: The aim of this study was to compare the monolithic and layered zirconia crowns by their optical property of translucency, using in vitro and in vivo evaluation methods.
Material and Methods: One upper incisor and one canine were prepared to receive 6 monolithic Lava Plus HT and 6 layered Lava crowns using the CAD/CAM technology.
The translucency in the vitro evaluation, was determined using a digital photoradiometer to measure the light reflected by the crowns in two different conditions, natural and metal plated abutment tooth.
A provisional complete prosthesis of an edentulous patient, with the abutment teeth mounted in their anatomical position, was used for the in vivo evaluation.
The crowns were randomly placed and evaluated by two independent operators in the oral cavity conditions.
Results: In vitro results showed that monolithic crowns were not significantly less translucent than layered ones in both incisor (p=0.
098) and canine (p=0.
340): contrast ratio 0.
978 vs.
0.
956 and 0.
941 vs.
0.
929, respectively (Student -t test; a=0.
05).
In vivo evaluation results showed that the difference in the luminance was not statistically significant between Lava Plus HT and layered Lava crowns according to Mann Whitney Test, p=0.
089 (a=0.
01).
Conclusions: The difference in translucency between monolithic and layered zirconia crowns was not statistically significant both in vitro and in vivo evaluation.
Monolithic zirconia had a good masking ability of the abutment tooth.
Related Results
Effect of Milling Protocols on Trueness and Precision of Ceramic Crowns
Effect of Milling Protocols on Trueness and Precision of Ceramic Crowns
AbstractPurposeTo investigate the effect of different milling protocols for different ceramic materials on the trueness and precision of milled ceramic crowns.Materials and Methods...
Masking Ability of Monolithic and Layered Zirconia Crowns on Discolored Substrates
Masking Ability of Monolithic and Layered Zirconia Crowns on Discolored Substrates
There is scarce information on the colorimetric behavior of monolithic and layered zirconia crowns in combination with various abutment colors. This study evaluated the masking abi...
The Performance of PEKK vs Zirconia Abutments for Screw-Retained Crowns in Two-Piece Zirconia Implants: An in vitro Study
The Performance of PEKK vs Zirconia Abutments for Screw-Retained Crowns in Two-Piece Zirconia Implants: An in vitro Study
This study aimed to compare the in vitro performance of anterior and posterior crowns with screw-retained polyetherketoneketone (PEKK) or zirconia abutments on two-piece zirconia i...
Comparative evaluation of stress generation in primary teeth restored with zirconia and BioFlx crowns: A finite element analysis
Comparative evaluation of stress generation in primary teeth restored with zirconia and BioFlx crowns: A finite element analysis
Background: Maintaining the functional integrity of primary teeth is important, as these teeth are integral in vital functions such as mastication, speech development, and space ma...
Assessing the Longevity of Zirconia-Based Crowns in Bruxism Patients
Assessing the Longevity of Zirconia-Based Crowns in Bruxism Patients
ABSTRACT
Background:
Bruxism is a parafunctional habit that often leads to excessive wear and tear of dental restoration...
Fit, Precision, and Trueness of 3D-Printed Zirconia Crowns Compared to Milled Counterparts
Fit, Precision, and Trueness of 3D-Printed Zirconia Crowns Compared to Milled Counterparts
Precise fit of a crown and accurate reproduction of the digital design are paramount for successful treatment outcomes and preservation of clinician and technician time. The study ...
Effect of coping materials zirconia or polyetheretherketone with different techniques of fabrication on vertical marginal gap and fracture resistance of posterior crowns with composite veneering
Effect of coping materials zirconia or polyetheretherketone with different techniques of fabrication on vertical marginal gap and fracture resistance of posterior crowns with composite veneering
Abstract
Background
Insufficient research has been conducted in the literature assessing the performance of zirconia and polyetheretherketone (PEEK)...
Surface roughness and optical characteristics evaluations after chairside adjustment of different zirconia types
Surface roughness and optical characteristics evaluations after chairside adjustment of different zirconia types
AbstractStatement of ProblemLimited evidence is available for the effect of chairside adjustment using rotary cutting instruments on the surface roughness and optical properties of...