Fit, Precision, and Trueness of 3D-Printed Zirconia Crowns Compared to Milled Counterparts

View through CrossRef
Precise fit of a crown and accurate reproduction of the digital design are paramount for successful treatment outcomes and preservation of clinician and technician time. The study aimed to compare the internal fit, marginal adaptation, precision, and trueness of 3D-printed zirconia crowns compared to their milled counterpart. A total of 20 monolithic 3 mol% yttria stabilized-zirconia crowns (n = 10) were made using computer-assisted design (CAD) followed by additive (3D-printed) and subtractive (milled) manufacturing. Digital scanning of the master die with and without a fit checker followed by image superimposition, and analysis was performed to evaluate internal and marginal adaptation in four areas (occlusal, axial, marginal, and overall). ISO 12836:2015 standard was followed for precision and trueness evaluation. Statistical analysis was achieved using a t-test at α = 0.05. Internal fit and marginal adaptation revealed no significant difference between the two test groups (p > 0.05). The significant difference in trueness (p < 0.05) was found between the two groups in three areas (occlusal, axial, and internal). The best and worst trueness values were seen with 3D-printed crowns at occlusal (8.77 ± 0.89 µm) and Intaglio (23.90 ± 1.60 µm), respectively. The overall precision was statistically better (p < 0.05) in the 3D-printed crowns (9.59 ± 0.75 µm) than the milled (17.31 ± 3.39 µm). 3D-printed and milled zirconia crowns were comparable to each other in terms of internal fit and marginal adaptation. The trueness of the occlusal and axial surfaces of 3D-printed crowns was better, whereas the trueness of fitting surface of milled crowns was better. 3D-printed crowns provided a higher level of precision than milled crowns. Although the internal and marginal fit of both production techniques were comparable, 3D printing of zirconia produced more precise crowns.
Title: Fit, Precision, and Trueness of 3D-Printed Zirconia Crowns Compared to Milled Counterparts
Description:
Precise fit of a crown and accurate reproduction of the digital design are paramount for successful treatment outcomes and preservation of clinician and technician time.
The study aimed to compare the internal fit, marginal adaptation, precision, and trueness of 3D-printed zirconia crowns compared to their milled counterpart.
A total of 20 monolithic 3 mol% yttria stabilized-zirconia crowns (n = 10) were made using computer-assisted design (CAD) followed by additive (3D-printed) and subtractive (milled) manufacturing.
Digital scanning of the master die with and without a fit checker followed by image superimposition, and analysis was performed to evaluate internal and marginal adaptation in four areas (occlusal, axial, marginal, and overall).
ISO 12836:2015 standard was followed for precision and trueness evaluation.
Statistical analysis was achieved using a t-test at α = 0.
05.
Internal fit and marginal adaptation revealed no significant difference between the two test groups (p > 0.
05).
The significant difference in trueness (p < 0.
05) was found between the two groups in three areas (occlusal, axial, and internal).
The best and worst trueness values were seen with 3D-printed crowns at occlusal (8.
77 ± 0.
89 µm) and Intaglio (23.
90 ± 1.
60 µm), respectively.
The overall precision was statistically better (p < 0.
05) in the 3D-printed crowns (9.
59 ± 0.
75 µm) than the milled (17.
31 ± 3.
39 µm).
3D-printed and milled zirconia crowns were comparable to each other in terms of internal fit and marginal adaptation.
The trueness of the occlusal and axial surfaces of 3D-printed crowns was better, whereas the trueness of fitting surface of milled crowns was better.
3D-printed crowns provided a higher level of precision than milled crowns.
Although the internal and marginal fit of both production techniques were comparable, 3D printing of zirconia produced more precise crowns.

Related Results

Effect of Milling Protocols on Trueness and Precision of Ceramic Crowns
Effect of Milling Protocols on Trueness and Precision of Ceramic Crowns
AbstractPurposeTo investigate the effect of different milling protocols for different ceramic materials on the trueness and precision of milled ceramic crowns.Materials and Methods...
Comparative evaluation of stress generation in primary teeth restored with zirconia and BioFlx crowns: A finite element analysis
Comparative evaluation of stress generation in primary teeth restored with zirconia and BioFlx crowns: A finite element analysis
Background: Maintaining the functional integrity of primary teeth is important, as these teeth are integral in vital functions such as mastication, speech development, and space ma...
The Performance of PEKK vs Zirconia Abutments for Screw-Retained Crowns in Two-Piece Zirconia Implants: An in vitro Study
The Performance of PEKK vs Zirconia Abutments for Screw-Retained Crowns in Two-Piece Zirconia Implants: An in vitro Study
This study aimed to compare the in vitro performance of anterior and posterior crowns with screw-retained polyetherketoneketone (PEKK) or zirconia abutments on two-piece zirconia i...
Masking Ability of Monolithic and Layered Zirconia Crowns on Discolored Substrates
Masking Ability of Monolithic and Layered Zirconia Crowns on Discolored Substrates
There is scarce information on the colorimetric behavior of monolithic and layered zirconia crowns in combination with various abutment colors. This study evaluated the masking abi...
Assessing the Longevity of Zirconia-Based Crowns in Bruxism Patients
Assessing the Longevity of Zirconia-Based Crowns in Bruxism Patients
ABSTRACT Background: Bruxism is a parafunctional habit that often leads to excessive wear and tear of dental restoration...
Comparing the Repair of Veneered Zirconia Crowns with Ceramic or Composite Resin: An in Vitro Study
Comparing the Repair of Veneered Zirconia Crowns with Ceramic or Composite Resin: An in Vitro Study
Statement of problem: Current techniques for repairing porcelain-chipped restorations have several limitations. With advances in CAD/CAM technology, the combination of resin cement...

Back to Top