Javascript must be enabled to continue!
Effect of Milling Protocols on Trueness and Precision of Ceramic Crowns
View through CrossRef
AbstractPurposeTo investigate the effect of different milling protocols for different ceramic materials on the trueness and precision of milled ceramic crowns.Materials and MethodsA definitive impression from a patient requiring a ceramic crown was used to fabricate forty glass ceramic crowns (VITABLOCS mark II, Vita Zahnfabrik) milled with wet, hard milling protocol, and 40 zirconia crowns (inCoris TZI, Dentsply, Sirona) milled with dry, soft milling protocol, using a 5‐axis milling machine (inLab MC X5; Dentsply Sirona). Trueness and precision for different crown areas were evaluated with a 3D evaluation software (Geomagic Control X, 3D systems). Statistical analysis was performed between the 2 crown types with independent t‐test, and analysis of variances followed by Bonferroni tests among crown areas for each crown.ResultsAll areas of the glass ceramic crowns had higher trueness than the zirconia crown areas (p < 0.05). Crown areas of each crown type had significantly different trueness values (p < 0.001, F = 175.17 for glass crowns, p < 0.001, F = 35.04 for zirconia crowns). Glass crowns had 3.78 µm precision, while zirconia crowns had 4.12 µm precision, with a precision difference range between the 2 types of crowns from 0.32 µm for the inner surface to 6.5 µm for the marginal surface.ConclusionsType of ceramic material and milling protocol affected trueness of the milled crown, with higher trueness for the hardmilled glass crowns than the soft milled zirconia crowns. Soft milled zirconia crowns were generally overmilled in comparison with the reference design and glass crowns. However, glass crowns exhibited more undermilling in thin and deep areas. The crown area affected trueness, with external areas having better trueness than internal areas. The 5‐axis milling machine had high precision, which was minimally affected by the ceramic type, milling protocol, or crown area.
Title: Effect of Milling Protocols on Trueness and Precision of Ceramic Crowns
Description:
AbstractPurposeTo investigate the effect of different milling protocols for different ceramic materials on the trueness and precision of milled ceramic crowns.
Materials and MethodsA definitive impression from a patient requiring a ceramic crown was used to fabricate forty glass ceramic crowns (VITABLOCS mark II, Vita Zahnfabrik) milled with wet, hard milling protocol, and 40 zirconia crowns (inCoris TZI, Dentsply, Sirona) milled with dry, soft milling protocol, using a 5‐axis milling machine (inLab MC X5; Dentsply Sirona).
Trueness and precision for different crown areas were evaluated with a 3D evaluation software (Geomagic Control X, 3D systems).
Statistical analysis was performed between the 2 crown types with independent t‐test, and analysis of variances followed by Bonferroni tests among crown areas for each crown.
ResultsAll areas of the glass ceramic crowns had higher trueness than the zirconia crown areas (p < 0.
05).
Crown areas of each crown type had significantly different trueness values (p < 0.
001, F = 175.
17 for glass crowns, p < 0.
001, F = 35.
04 for zirconia crowns).
Glass crowns had 3.
78 µm precision, while zirconia crowns had 4.
12 µm precision, with a precision difference range between the 2 types of crowns from 0.
32 µm for the inner surface to 6.
5 µm for the marginal surface.
ConclusionsType of ceramic material and milling protocol affected trueness of the milled crown, with higher trueness for the hardmilled glass crowns than the soft milled zirconia crowns.
Soft milled zirconia crowns were generally overmilled in comparison with the reference design and glass crowns.
However, glass crowns exhibited more undermilling in thin and deep areas.
The crown area affected trueness, with external areas having better trueness than internal areas.
The 5‐axis milling machine had high precision, which was minimally affected by the ceramic type, milling protocol, or crown area.
Related Results
Fit, Precision, and Trueness of 3D-Printed Zirconia Crowns Compared to Milled Counterparts
Fit, Precision, and Trueness of 3D-Printed Zirconia Crowns Compared to Milled Counterparts
Precise fit of a crown and accurate reproduction of the digital design are paramount for successful treatment outcomes and preservation of clinician and technician time. The study ...
Comparative In vitro Analysis of Characteristics Between CAD-CAM Fabricated Ceramic Crowns and 3D-Printed Resin-Based Dental Crowns
Comparative In vitro Analysis of Characteristics Between CAD-CAM Fabricated Ceramic Crowns and 3D-Printed Resin-Based Dental Crowns
Objectives: Dental crown clinical longevity mainly depends on how materials resist wear and maintain their surface quality. Three-Dimensionally (3D) printed resin-based crowns and ...
ecision Farming and Predictive Analytics in Precision Farming and Predictive Analytics in Precision Farming and Predictive Analytics in Precision Farming and Predictive Analytics in Precision Farming and Predictive Analytics in Precision Farming and Predi
ecision Farming and Predictive Analytics in Precision Farming and Predictive Analytics in Precision Farming and Predictive Analytics in Precision Farming and Predictive Analytics in Precision Farming and Predictive Analytics in Precision Farming and Predi
The scope of sensor networks and the Internet of Things spanning rapidly to diversified domains but not limited to sports, health, and business trading. In recent past, the sensors...
Effect of Milling Strategy on the Surface Quality of AISI P20 Mold Steel
Effect of Milling Strategy on the Surface Quality of AISI P20 Mold Steel
This paper explores the impact of various milling strategies, including up-milling, down-milling, and hybrid approaches, on the surface roughness of AISI P20 mold steel. The study ...
Effect of scanning pathways on trueness and precision in full-arch optical impression
Effect of scanning pathways on trueness and precision in full-arch optical impression
Abstract
Background: In this study, we investigate the effect of differences in scanning pathway during optical impression on the trueness and precision of full-arch impres...
Comparative evaluation of stress generation in primary teeth restored with zirconia and BioFlx crowns: A finite element analysis
Comparative evaluation of stress generation in primary teeth restored with zirconia and BioFlx crowns: A finite element analysis
Background: Maintaining the functional integrity of primary teeth is important, as these teeth are integral in vital functions such as mastication, speech development, and space ma...
Comparing the Repair of Veneered Zirconia Crowns with Ceramic or Composite Resin: An in Vitro Study
Comparing the Repair of Veneered Zirconia Crowns with Ceramic or Composite Resin: An in Vitro Study
Statement of problem: Current techniques for repairing porcelain-chipped restorations have several limitations. With advances in CAD/CAM technology, the combination of resin cement...
Effects of Operator Experience and Scanning Distance on Intraoral Scanner Accuracy
Effects of Operator Experience and Scanning Distance on Intraoral Scanner Accuracy
Aim: This study aimed to evaluate the effect of operator experience and scanning distance on the accuracy of the intraoral scanner in terms of trueness and precision.
Material and ...