Analisis Struktur Beton Bertulang Tahan Gempa Untuk Berbagai Variasi Tinggi Bangunan
View through CrossRef
Indonesia is a country prone to earthquakes because it is located at the confluence of the Pacific and Trans-Asiatic Circum. Padang is included in the 5-6 earthquake area (KDS E & F), which is an area that has the potential for an earthquake accompanied by the possibility of a tsunami., comfortable and safe against the dangers of an earthquake or tsunami. The most influential factor in the planning of high-rise building structures is the strength of the building structure itself, where this factor is closely related to the safety and resilience of the building in holding and accommodating the loads acting on the structure. Instability in the structure is a basic thing that must be avoided and considered for various types of building heights. An unstable structure when subjected to loads causes the structure to experience a greater deformation than a stable structure. One way that can be done to make the structure more stable is to combine the structure with Shear Walls. Shear wall systems can be used to withstand vertical forces such as gravity loads and horizontal/lateral forces such as earthquake and tsunami loads, thereby preventing excessive swaying of the structure. The use of shear walls is also intended so that when an earthquake and tsunami occurs, the lateral forces that affect the structure are not only resisted by the beam and column elements in the structure but are also resisted by the shear wall system. because the placement of the shear walls that are not appropriate causes the shear forces that occur in the columns and beams to be greater. The research object is multi-storey reinforced concrete buildings with variations in height of 5, 7, 10, 15 and 20 floors. Buildings 5, 7 and 10 floors are designed with an open frame system, while buildings with floors 7, 10, 15 and 20 are designed with a double system, namely open portals and shear walls as lateral load resisters. Open portals use a Special Moment Resisting Frame System (SRPMK) design, while shear walls use a Special Structural Wall System (SDSK) design. The calculated structural loads are dead loads, live loads, superimposed dead loads and earthquake loads. Building location in the city of Padang with moderate soil conditions. The strength and stiffness of structures with shear walls are higher than those without shear walls
Universitas Batanghari Jambi
Title: Analisis Struktur Beton Bertulang Tahan Gempa Untuk Berbagai Variasi Tinggi Bangunan
Description:
Indonesia is a country prone to earthquakes because it is located at the confluence of the Pacific and Trans-Asiatic Circum.
Padang is included in the 5-6 earthquake area (KDS E & F), which is an area that has the potential for an earthquake accompanied by the possibility of a tsunami.
, comfortable and safe against the dangers of an earthquake or tsunami.
The most influential factor in the planning of high-rise building structures is the strength of the building structure itself, where this factor is closely related to the safety and resilience of the building in holding and accommodating the loads acting on the structure.
Instability in the structure is a basic thing that must be avoided and considered for various types of building heights.
An unstable structure when subjected to loads causes the structure to experience a greater deformation than a stable structure.
One way that can be done to make the structure more stable is to combine the structure with Shear Walls.
Shear wall systems can be used to withstand vertical forces such as gravity loads and horizontal/lateral forces such as earthquake and tsunami loads, thereby preventing excessive swaying of the structure.
The use of shear walls is also intended so that when an earthquake and tsunami occurs, the lateral forces that affect the structure are not only resisted by the beam and column elements in the structure but are also resisted by the shear wall system.
because the placement of the shear walls that are not appropriate causes the shear forces that occur in the columns and beams to be greater.
The research object is multi-storey reinforced concrete buildings with variations in height of 5, 7, 10, 15 and 20 floors.
Buildings 5, 7 and 10 floors are designed with an open frame system, while buildings with floors 7, 10, 15 and 20 are designed with a double system, namely open portals and shear walls as lateral load resisters.
Open portals use a Special Moment Resisting Frame System (SRPMK) design, while shear walls use a Special Structural Wall System (SDSK) design.
The calculated structural loads are dead loads, live loads, superimposed dead loads and earthquake loads.
Building location in the city of Padang with moderate soil conditions.
The strength and stiffness of structures with shear walls are higher than those without shear walls.
Related Results
ANALISIS KUAT TARIK BELAH BETON PADA STANDAR KUAT TEKAN K.250 DENGAN MENGGUNAKAN LIMBAH PECAHAN BETON SEBAGAI PENGGANTI AGREGAT KASAR
ANALISIS KUAT TARIK BELAH BETON PADA STANDAR KUAT TEKAN K.250 DENGAN MENGGUNAKAN LIMBAH PECAHAN BETON SEBAGAI PENGGANTI AGREGAT KASAR
Beton merupakan bahan konstruksi yang sangat penting dan paling dominan digunakan pada struktur bangunan. Beton sangat diminati karena bahan ini merupakan bahan konstruksi yang mem...
Studi Pemanfaatan Limbah Serat Gergaji Kayu dan Limbah Kertas Sebagai Campuran Beton Ringan
Studi Pemanfaatan Limbah Serat Gergaji Kayu dan Limbah Kertas Sebagai Campuran Beton Ringan
Limbah sering digunakan sebagai bahan untuk berbagai keperluan, termasuk dalam rekayasa bahan bangunan. Salah satu jenis limbah yang masih jarang diteliti sebagai campuran dalam pe...
Pengaruh Dinding Bata Terhadap Kapasitas Seismik Gedung Beton Bertulang Berlantai Banyak
Pengaruh Dinding Bata Terhadap Kapasitas Seismik Gedung Beton Bertulang Berlantai Banyak
Studi ini menjelaskan tentang pengaruh dinding bata terhadap kapasitas seismik gedung beton bertulang. Di kota Padang, dinding bata digunakan sebagai dinding non struktural pada se...
Pengaruh Dinding Bata terhadap Kapasitas Seismik Gedung Beton Bertulang Berlantai Banyak
Pengaruh Dinding Bata terhadap Kapasitas Seismik Gedung Beton Bertulang Berlantai Banyak
Studi ini menjelaskan tentang pengaruh dinding bata terhadap kapasitas seismik gedung beton bertulang. Di kota Padang, dinding bata digunakan sebagai dinding non struktural pada se...
ANALISIS PENURUNAN MUTU BETON STRUKTURAL AKIBAT PENGARUH AIR LAUT PADA MASA PEMELIHARAAN
ANALISIS PENURUNAN MUTU BETON STRUKTURAL AKIBAT PENGARUH AIR LAUT PADA MASA PEMELIHARAAN
Air laut memiliki kandungan garam yang tinggi yang dapat menggerogoti kekuatan dan keawetan beton. Hal ini disebabkan klorida yang terdapat pada air laut yang merupakan garam yang ...
Pengaruh Serat Baja Canai Dingin Bergelombang Terhadap Kekuatan Tekan Dan Lentur Beton
Pengaruh Serat Baja Canai Dingin Bergelombang Terhadap Kekuatan Tekan Dan Lentur Beton
Beton merupakan material konstruksi yang bersifat getas. Kombinasinya dengan baja pada material beton bertulang menjadikan material beton yang getas getas menjadi daktail. Pada bet...
ANALISA KAPASITAS SEISMIK DENGAN DAN TANPA DINDING BATA PADA GEDUNG BETON BERTULANG
ANALISA KAPASITAS SEISMIK DENGAN DAN TANPA DINDING BATA PADA GEDUNG BETON BERTULANG
Makalah ini menjelaskan pengaruh dinding bata terhadap kapasitas seismik gedung beton bertulang berlantai banyak. Di Kota Padang, sebagian besar bangunan beton bertulang menggunak...
Aspek Rasio Vertikal terhadap Kestabilan Struktur
Aspek Rasio Vertikal terhadap Kestabilan Struktur
Perilaku bangunan selama gempa bumi sangat berpengaruh terhadap bentuk, ukuran dan geometri bangunan. Bangunan tinggi dengan aspek rasio vertikal yang besar berpengaruh terhadap re...