Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Refrigerant Subcooling Correlations for Different Expansion Devices for a Non-Intrusive Charge Indicator

View through CrossRef
The most common problems affecting residential and light commercial heating, ventilation, and air-conditioning (HVAC) systems are slow refrigerant leaks. Equipment users are usually not aware of the problem until most of the refrigerant has escaped. A low-cost, non-intrusive refrigerant charge indicator has been developed, based on temperature measurements and correlations formed to interpret the measured temperatures. It can be used to provide real time warnings to the equipment users before the majority of refrigerant is escaped. It could be inexpensive and easy to incorporate into existing heat pumps and air conditioners. Extensive laboratory experimental work was performed on a 2-ton window air conditioner and on a 2.5 ton split heat pump system. It was found that the heat pump was not sensitive to slow refrigerant leak because of the long liquid line. Liquid subcooling was measured to determine the system charge status before a substantial amount of refrigerant was leaked. This study reports the finding of correlations formed for liquid subcooling for the orifice plate and thermal expansion valve used on the heat pump system for both heating and cooling mode operation.
Title: Refrigerant Subcooling Correlations for Different Expansion Devices for a Non-Intrusive Charge Indicator
Description:
The most common problems affecting residential and light commercial heating, ventilation, and air-conditioning (HVAC) systems are slow refrigerant leaks.
Equipment users are usually not aware of the problem until most of the refrigerant has escaped.
A low-cost, non-intrusive refrigerant charge indicator has been developed, based on temperature measurements and correlations formed to interpret the measured temperatures.
It can be used to provide real time warnings to the equipment users before the majority of refrigerant is escaped.
It could be inexpensive and easy to incorporate into existing heat pumps and air conditioners.
Extensive laboratory experimental work was performed on a 2-ton window air conditioner and on a 2.
5 ton split heat pump system.
It was found that the heat pump was not sensitive to slow refrigerant leak because of the long liquid line.
Liquid subcooling was measured to determine the system charge status before a substantial amount of refrigerant was leaked.
This study reports the finding of correlations formed for liquid subcooling for the orifice plate and thermal expansion valve used on the heat pump system for both heating and cooling mode operation.

Related Results

PERANCANGAN SISTEM KERJA SIMULATOR AC (AIR CONDITIONER) MOBIL
PERANCANGAN SISTEM KERJA SIMULATOR AC (AIR CONDITIONER) MOBIL
Sistem AC memiliki beberapa komponen yaitu kompresor, kondensor, receiver dryer, katup ekspansi dan evaporator, yang mana memiliki fungsinya tersendiri. Untuk itu perlu adanya suat...
Comparison of Subcooling Effect of Water as a Refrigerant With the Current Refrigerants
Comparison of Subcooling Effect of Water as a Refrigerant With the Current Refrigerants
The performance comparison of water as a refrigerant (R718) with some prevailing refrigerants including R717, R290, R134a, R12, R22, and R152a is presented. A computer program simu...
Analisa Pengaruh Variasi Susunan Pipa Kondensor, Masa Refrigerant, dan Kecepatan Aliran Udara Kondensor Terhadap Performa Kulkas R-600a
Analisa Pengaruh Variasi Susunan Pipa Kondensor, Masa Refrigerant, dan Kecepatan Aliran Udara Kondensor Terhadap Performa Kulkas R-600a
This study aims to analyze the effects of condenser pipe configuration, refrigerant charge, and condenser airflow velocity on the performance of a refrigerator using R-600a refrige...
The Improvement of Energy Efficiency in Refrigeration Systems using Ultrasonic Sensors
The Improvement of Energy Efficiency in Refrigeration Systems using Ultrasonic Sensors
Climate change is still an important issue that needs concrete support and action. Refrigerant is also one material that affects global warming and international have plans to redu...
Advanced Dual Refrigerant Expansion Cycle for Liquefaction
Advanced Dual Refrigerant Expansion Cycle for Liquefaction
Abstract This paper presents a LNG Liquefaction cycle configuration using two stages of methane expansion and a single stage of nitrogen expansion (Dual Refrigerant)...
High Efficiency Subcool Condenser
High Efficiency Subcool Condenser
<div class="section abstract"><div class="htmlview paragraph">Sustainable reduction of the CO2 emissions of future vehicles goes hand in hand with the increase in effic...
Research on Online Monitoring Technology of Refrigerant Charge in Airborne Liquid-Cooled - Evaporative Refrigeration System
Research on Online Monitoring Technology of Refrigerant Charge in Airborne Liquid-Cooled - Evaporative Refrigeration System
Liquid-cooled evaporation refrigeration systems are an efficient thermal management solution widely employed in aircraft applications. The refrigerant charge amount significantly i...

Back to Top