<div class="section abstract"><div class="htmlview paragraph">Sustainable reduction of the CO2 emissions of future vehicles goes hand in hand with the increase in efficiency of ancillary units. Of particular importance is the reduction of fuel consumption attributed to the vehicle's air conditioning system. The innovative development of a condenser with a 3-pass subcooling zone renders it possible to significantly increase the efficiency of the cooling circuit. This is applicable both in the case of current and future refrigerants.</div><div class="htmlview paragraph">The basis for increasing the efficiency of the condenser is rooted in the systematic analysis of the local heat transfer functions, pressure drops and implementation of an improved flow path configuration. The current condenser design, which includes the functionality of a receiver/dryer with a dedicated subcooling zone, is effective at providing stable liquid refrigerant to the TXV under a variety of conditions. By optimally adapting the flow cross-section to the density change of the refrigerant and increasing the subcooling function by means of a 3-pass flow subcooling zone, it is possible to achieve a significantly lower outlet temperature of the refrigerant. The locally higher pressure drop in the subcooling zone does not have a negative impact on the vapor compression circuit and can therefore be used to increase efficiency without the risk of losses.</div><div class="htmlview paragraph">The theoretical derivation, as well as simulation and measurement results for the new condenser, are presented and discussed in comparison with conventional designs. A new condenser specification has been derived and validated for the system-oriented evaluation of the component. Finally, the validation results from the circuit and vehicle measurements in the wind tunnel are presented. The newly developed condenser resulted in a significant increase of 4% of evaporator performance while maintaining mass and package space. Alternatively, weight and conduction depth can be reduced by 25% while maintaining capacity and system efficiency.</div></div>
Title: High Efficiency Subcool Condenser
Description:
<div class="section abstract"><div class="htmlview paragraph">Sustainable reduction of the CO2 emissions of future vehicles goes hand in hand with the increase in efficiency of ancillary units.
Of particular importance is the reduction of fuel consumption attributed to the vehicle's air conditioning system.
The innovative development of a condenser with a 3-pass subcooling zone renders it possible to significantly increase the efficiency of the cooling circuit.
This is applicable both in the case of current and future refrigerants.
</div><div class="htmlview paragraph">The basis for increasing the efficiency of the condenser is rooted in the systematic analysis of the local heat transfer functions, pressure drops and implementation of an improved flow path configuration.
The current condenser design, which includes the functionality of a receiver/dryer with a dedicated subcooling zone, is effective at providing stable liquid refrigerant to the TXV under a variety of conditions.
By optimally adapting the flow cross-section to the density change of the refrigerant and increasing the subcooling function by means of a 3-pass flow subcooling zone, it is possible to achieve a significantly lower outlet temperature of the refrigerant.
The locally higher pressure drop in the subcooling zone does not have a negative impact on the vapor compression circuit and can therefore be used to increase efficiency without the risk of losses.
</div><div class="htmlview paragraph">The theoretical derivation, as well as simulation and measurement results for the new condenser, are presented and discussed in comparison with conventional designs.
A new condenser specification has been derived and validated for the system-oriented evaluation of the component.
Finally, the validation results from the circuit and vehicle measurements in the wind tunnel are presented.
The newly developed condenser resulted in a significant increase of 4% of evaporator performance while maintaining mass and package space.
Alternatively, weight and conduction depth can be reduced by 25% while maintaining capacity and system efficiency.
</div></div>.
Related Results
Artificial Lift-A Major Unresolved Issue for SAGD
Artificial Lift-A Major Unresolved Issue for SAGD
Abstract
Lower-pressure SAGD may be required because of thief zones, or to improve the SOR, emissions, and water use. Simple 3D simulation examples representing r...
Analisa Pengaruh Variasi Susunan Pipa Kondensor, Masa Refrigerant, dan Kecepatan Aliran Udara Kondensor Terhadap Performa Kulkas R-600a
Analisa Pengaruh Variasi Susunan Pipa Kondensor, Masa Refrigerant, dan Kecepatan Aliran Udara Kondensor Terhadap Performa Kulkas R-600a
This study aims to analyze the effects of condenser pipe configuration, refrigerant charge, and condenser airflow velocity on the performance of a refrigerator using R-600a refrige...
ENERGY AND EXERGY ANALYSIS OF A DOMESTIC REFRIGERATOR: APPROACHING A SUSTAINABLE REFRIGERATOR
ENERGY AND EXERGY ANALYSIS OF A DOMESTIC REFRIGERATOR: APPROACHING A SUSTAINABLE REFRIGERATOR
In the perspective of reducing the household energy consumption, current research in conventional refrigeration is
concentrating on introducing innovative designs and enhances the...
Research on Spacing Design Method of Condenser Half-Side Operation in Pressurized Water Reactor Nuclear Power Plant
Research on Spacing Design Method of Condenser Half-Side Operation in Pressurized Water Reactor Nuclear Power Plant
Abstract
The condenser of Pressurized Water Reactor (PWR) nuclear power plant in China has many cooling tube leakage events, resulting in serious safety impact and e...
CONDENSOR DESIGN ANALYSIS WITH KAYS AND LONDON SURFACE DIMENSIONS
CONDENSOR DESIGN ANALYSIS WITH KAYS AND LONDON SURFACE DIMENSIONS
The use of condensers in air conditioning units is more common in large-capacity units than in ones with a smaller capacity. Air conditioning provides comfort and freshness to an a...
Study of Vibration and Sound Transmission Characteristics in Condenser Pipe System
Study of Vibration and Sound Transmission Characteristics in Condenser Pipe System
Effect of surrounding fluid or steam flow fluctuation on internal flow fluctuation in heat transfer pipe is analyzed based on fluid and structure interaction simulation by using co...
Comparison between Heat Pipes based condenser and Conventional condenser of Power Plant
Comparison between Heat Pipes based condenser and Conventional condenser of Power Plant
Abstract
This paper explores the feasibility of using heat pipes for steam condensation and heat pipe based condenser. The concept of heat pipes for steam condensation is ...
Laser ultrasonic guided waves deep subdomain transfer detection method for air-conditioning condenser pipelines
Laser ultrasonic guided waves deep subdomain transfer detection method for air-conditioning condenser pipelines
Abstract
The air-conditioning condenser (ACC) is a critical component of air conditioning systems, where the curved pipe connections pose challenges for tradition...