Javascript must be enabled to continue!
High Efficiency Subcool Condenser
View through CrossRef
<div class="section abstract"><div class="htmlview paragraph">Sustainable reduction of the CO2 emissions of future vehicles goes hand in hand with the increase in efficiency of ancillary units. Of particular importance is the reduction of fuel consumption attributed to the vehicle's air conditioning system. The innovative development of a condenser with a 3-pass subcooling zone renders it possible to significantly increase the efficiency of the cooling circuit. This is applicable both in the case of current and future refrigerants.</div><div class="htmlview paragraph">The basis for increasing the efficiency of the condenser is rooted in the systematic analysis of the local heat transfer functions, pressure drops and implementation of an improved flow path configuration. The current condenser design, which includes the functionality of a receiver/dryer with a dedicated subcooling zone, is effective at providing stable liquid refrigerant to the TXV under a variety of conditions. By optimally adapting the flow cross-section to the density change of the refrigerant and increasing the subcooling function by means of a 3-pass flow subcooling zone, it is possible to achieve a significantly lower outlet temperature of the refrigerant. The locally higher pressure drop in the subcooling zone does not have a negative impact on the vapor compression circuit and can therefore be used to increase efficiency without the risk of losses.</div><div class="htmlview paragraph">The theoretical derivation, as well as simulation and measurement results for the new condenser, are presented and discussed in comparison with conventional designs. A new condenser specification has been derived and validated for the system-oriented evaluation of the component. Finally, the validation results from the circuit and vehicle measurements in the wind tunnel are presented. The newly developed condenser resulted in a significant increase of 4% of evaporator performance while maintaining mass and package space. Alternatively, weight and conduction depth can be reduced by 25% while maintaining capacity and system efficiency.</div></div>
Title: High Efficiency Subcool Condenser
Description:
<div class="section abstract"><div class="htmlview paragraph">Sustainable reduction of the CO2 emissions of future vehicles goes hand in hand with the increase in efficiency of ancillary units.
Of particular importance is the reduction of fuel consumption attributed to the vehicle's air conditioning system.
The innovative development of a condenser with a 3-pass subcooling zone renders it possible to significantly increase the efficiency of the cooling circuit.
This is applicable both in the case of current and future refrigerants.
</div><div class="htmlview paragraph">The basis for increasing the efficiency of the condenser is rooted in the systematic analysis of the local heat transfer functions, pressure drops and implementation of an improved flow path configuration.
The current condenser design, which includes the functionality of a receiver/dryer with a dedicated subcooling zone, is effective at providing stable liquid refrigerant to the TXV under a variety of conditions.
By optimally adapting the flow cross-section to the density change of the refrigerant and increasing the subcooling function by means of a 3-pass flow subcooling zone, it is possible to achieve a significantly lower outlet temperature of the refrigerant.
The locally higher pressure drop in the subcooling zone does not have a negative impact on the vapor compression circuit and can therefore be used to increase efficiency without the risk of losses.
</div><div class="htmlview paragraph">The theoretical derivation, as well as simulation and measurement results for the new condenser, are presented and discussed in comparison with conventional designs.
A new condenser specification has been derived and validated for the system-oriented evaluation of the component.
Finally, the validation results from the circuit and vehicle measurements in the wind tunnel are presented.
The newly developed condenser resulted in a significant increase of 4% of evaporator performance while maintaining mass and package space.
Alternatively, weight and conduction depth can be reduced by 25% while maintaining capacity and system efficiency.
</div></div>.
Related Results
Artificial Lift-A Major Unresolved Issue for SAGD
Artificial Lift-A Major Unresolved Issue for SAGD
Abstract
Lower-pressure SAGD may be required because of thief zones, or to improve the SOR, emissions, and water use. Simple 3D simulation examples representing r...
Analisa Pengaruh Variasi Susunan Pipa Kondensor, Masa Refrigerant, dan Kecepatan Aliran Udara Kondensor Terhadap Performa Kulkas R-600a
Analisa Pengaruh Variasi Susunan Pipa Kondensor, Masa Refrigerant, dan Kecepatan Aliran Udara Kondensor Terhadap Performa Kulkas R-600a
This study aims to analyze the effects of condenser pipe configuration, refrigerant charge, and condenser airflow velocity on the performance of a refrigerator using R-600a refrige...
A Subcool Reactive ICD for Optimization of SAGD Wells
A Subcool Reactive ICD for Optimization of SAGD Wells
Abstract
A novel Flow Control Device (FCD) for Steam Assisted Gravity Drainage (SAGD) production wells is presented. This device increases the thermal efficiency of ...
ENERGY AND EXERGY ANALYSIS OF A DOMESTIC REFRIGERATOR: APPROACHING A SUSTAINABLE REFRIGERATOR
ENERGY AND EXERGY ANALYSIS OF A DOMESTIC REFRIGERATOR: APPROACHING A SUSTAINABLE REFRIGERATOR
In the perspective of reducing the household energy consumption, current research in conventional refrigeration is
concentrating on introducing innovative designs and enhances the...
Testing of a Freeze-proof Condenser for the Tracker Thermal Control System on AMS-02
Testing of a Freeze-proof Condenser for the Tracker Thermal Control System on AMS-02
<div class="htmlview paragraph">The paper describes freezing and pressure tests required to develop a freeze-proof condenser for the Tracker Thermal Control System (TTCS). Th...
Variation on hydraulic diameter for the different PETG condenser tube thickness
Variation on hydraulic diameter for the different PETG condenser tube thickness
One of the four major components of a refrigeration system is the condenser. It is where the refrigerant releases the heat it absorbed by condensing from vapor to liquid form. This...
Research on Electromagnetic Field, Eddy Current Loss and Heat Transfer in the End Region of Synchronous Condenser with Different End Structures and Material Properties
Research on Electromagnetic Field, Eddy Current Loss and Heat Transfer in the End Region of Synchronous Condenser with Different End Structures and Material Properties
Aiming at the problem of end structure heating caused by the excessive eddy current loss of large synchronous condensers used in ultra-high voltage (UHV) power transmission, combin...
Research on Spacing Design Method of Condenser Half-Side Operation in Pressurized Water Reactor Nuclear Power Plant
Research on Spacing Design Method of Condenser Half-Side Operation in Pressurized Water Reactor Nuclear Power Plant
Abstract
The condenser of Pressurized Water Reactor (PWR) nuclear power plant in China has many cooling tube leakage events, resulting in serious safety impact and e...

