Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Two-point diameter calibration of a sphere using a micro-coordinate measuring machine at NMIJ

View through CrossRef
Abstract The National Metrology Institute of Japan (NMIJ) has developed a highly accurate two-point diameter measurement method of a sphere using a micro-coordinate measuring machine (µ-CMM) with a low-force two-dimensional touch probe. The measured sphere is used as a reference to calibrate the probe of other µ-CMM in industry. Our strategy for measuring sphere’s diameter is that the probe radius of NMIJ’s µ-CMM is calibrated using a reference gauge block, and the NMIJ’s µ-CMM using the calibrated probe measures the mean two-point diameter of a sphere. To achieve the highly accurate calibration of the reference gauge block, we have adopted a double-sided interferometer (DSI) and an atomic force microscopy (AFM). The DSI measures the length of gauge block without wringing. The phase correction value of the gauge block is evaluated by measuring the surface roughness using the AFM. Using the DSI and AFM, the mechanical length of reference gauge block was obtained with the expanded uncertainty of 13 nm (k = 2). Then, the probe radius of NMIJ’s µ-CMM was also calibrated using the reference gauge block calibrated by the DSI and the AFM. The µ-CMM’s probe radius was obtained with the expanded uncertainty of 10 nm (k = 2). Finally, the µ-CMM measured the mean two-point diameter of a sphere with the expanded uncertainty 21 nm (k = 2) was demonstrated.
Title: Two-point diameter calibration of a sphere using a micro-coordinate measuring machine at NMIJ
Description:
Abstract The National Metrology Institute of Japan (NMIJ) has developed a highly accurate two-point diameter measurement method of a sphere using a micro-coordinate measuring machine (µ-CMM) with a low-force two-dimensional touch probe.
The measured sphere is used as a reference to calibrate the probe of other µ-CMM in industry.
Our strategy for measuring sphere’s diameter is that the probe radius of NMIJ’s µ-CMM is calibrated using a reference gauge block, and the NMIJ’s µ-CMM using the calibrated probe measures the mean two-point diameter of a sphere.
To achieve the highly accurate calibration of the reference gauge block, we have adopted a double-sided interferometer (DSI) and an atomic force microscopy (AFM).
The DSI measures the length of gauge block without wringing.
The phase correction value of the gauge block is evaluated by measuring the surface roughness using the AFM.
Using the DSI and AFM, the mechanical length of reference gauge block was obtained with the expanded uncertainty of 13 nm (k = 2).
Then, the probe radius of NMIJ’s µ-CMM was also calibrated using the reference gauge block calibrated by the DSI and the AFM.
The µ-CMM’s probe radius was obtained with the expanded uncertainty of 10 nm (k = 2).
Finally, the µ-CMM measured the mean two-point diameter of a sphere with the expanded uncertainty 21 nm (k = 2) was demonstrated.

Related Results

(Invited) Strategies for Calibration Cost Reduction in Heterogeneous Chemical Sensor Arrays
(Invited) Strategies for Calibration Cost Reduction in Heterogeneous Chemical Sensor Arrays
Introduction Heterogeneous gas sensor arrays coupled with machine learning algorithms have been proposed for a wide range of applications. However, i...
The influence of micro influencers and digital marketing on product purchasing decisions at tiktok shop in bengkulu city
The influence of micro influencers and digital marketing on product purchasing decisions at tiktok shop in bengkulu city
THE INFLUENCE OF MICRO-INFLUENCERS AND DIGITAL MARKETING ON PURCHASE DECISIONS OF TIKTOK SHOP CUSTOMERS IN BENGKULU CITY Andhes Tiani Putri, Meylaty F   12Faculty Of Economic E...
Automatic Hand-Eye Calibration Method of Welding Robot Based on Linear Structured Light
Automatic Hand-Eye Calibration Method of Welding Robot Based on Linear Structured Light
Aiming at solving the problems such as long calibration time, low precision, and complex operation in hand-eye calibration of welding robot, an automatic hand-eye calibration algor...
Radiometric cross-calibration of Sentinel-2B MSI with HY-1C SCS based on the near simultaneous imaging of common ground targets
Radiometric cross-calibration of Sentinel-2B MSI with HY-1C SCS based on the near simultaneous imaging of common ground targets
To simplify the cross-calibration process and improve calibration frequency and accuracy, this paper proposes a cross-calibration method for the multispectral remote sensor Multi-S...
A calibration method combining hand-eye calibration and TCP calibration
A calibration method combining hand-eye calibration and TCP calibration
Abstract Robots' traditional Tool Center Point (TCP) calibration and hand-eye calibration are implemented independently, which is likely to generate large cumulative errors...
Applicability of self-consistency calibration method for polarimetric cloud radars
Applicability of self-consistency calibration method for polarimetric cloud radars
Cloud radars are powerful tools for investigating cloud formation, radiative processes, and cloud microphysics. In recent years, polarimetric cloud radars have become increasingly ...
Binocular vision calibration method for a long-wavelength infrared camera and a visible spectrum camera with different resolutions
Binocular vision calibration method for a long-wavelength infrared camera and a visible spectrum camera with different resolutions
We present a calibration plate for the binocular vision system, which is composed of a long-wavelength infrared camera and a visible spectrum camera with different resolutions. The...
The Effect of the Accuracy of Various Measuring Devices on Recorded Joint Kinematics
The Effect of the Accuracy of Various Measuring Devices on Recorded Joint Kinematics
Knowledge of joint kinematics contributes to the understanding of the function of soft tissue restraints, injury mechanisms, and can be used to evaluate surgical repair techniques....

Back to Top